Beam test of FARICH prototype with digital photon counter Barnyakov, A.Yu; Barnyakov, M.Yu; Bobrovnikov, V.S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Letnik:
732
Journal Article
Recenzirano
In June 2012 we tested a Focusing Aerogel RICH detector prototype based on Digital Photon Counters (DPC) by Philips at the CERN PS T10 beam line with a particle momentum up to 6GeV/c. The prototype ...comprises a 20×20cm2 photon detector with 48×48 DPC pixels. In order to reduce the dark count rate, the photon detector was cooled to −40°C in addition to disabling individual DPC's microcells. A four layer focusing aerogel radiator with 200mm focal distance was studied. We obtained a Cherenkov angle resolution of 3.61±0.04mrad. The mean number of photoelectrons in a ring is 12. Directly measured π/K separation at 6GeV/c momentum is 3.5σ, μ/π separation is 5.3σ at 1GeV/c. A comparison with a Monte Carlo simulation is presented as well.
•Focusing Aerogel RICH prototype with Digital Photon Counters by Philips was built.•The prototype was tested at the CERN PS T10 beam line.•We observed Cherenkov rings with 12 photoelectrons in average.•Timing resolution of DPCs is 48ps for single photons.•Cherenkov angle resolution is 3.64±0.04mrad per ring.
Tests of FARICH prototype with precise photon position detection Barnyakov, A.Yu; Barnyakov, M.Yu; Basok, I.Yu ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2014, Letnik:
766
Journal Article
Recenzirano
In June 2012 a FARICH prototype from Philips Digital Photon Counting (PDPC) based on a photon camera with dimensions of 200200 mm has been tested at CERN. Remarkable particle separation has been ...achieved with a 4-layer aerogel sample: the pi /K separation at a 6 GeV/c momentum is 3.5 sigma , the mu / pi mu / pi separation is 5.3 sigma at 1 GeV/c. The analysis of the data has shown that the main contribution to the accuracy of the ring radius measurement comes from aerogel. The development of focusing aerogels is proceeding in two main directions: tuning of production technology of multilayer blocks and development of a new production method with continuous density (refractive index) gradient along the block depth. The beam test was carried out in December 2012-January 2013 at the electron beam test facility at the VEPP-4 M e super(+)e super(-) collider. The goal of this test was to measure different single layer and focusing aerogel samples, both multilayer and gradient. Aerogel samples were tested with a PDPC FARICH prototype. A part of DPC SPADs in each pixel was disabled to form an active area of 11 mm super(2). The collected data proved that gradient aerogel samples focus Cherenkov light.
This work has its focus on the development of fast read-out electronics for digital silicon photomultipliers (dSiPM -called Digital Photon Counter (DPC) by Philips).
ChromAIX is an ASIC for fast single photon-counting designed to study the feasibility of energy-resolved photon-counting human Spectral CT. It allows for reading out 4 × 16 pixels of a direct ...converting sensor made of CdZnTe with a pixel pitch of about 300μm. It supports K-edge imaging 3. After thorough electrical testing reported in 6 characterization under g- and X-rays was done giving promising results as to the behavior of the ASIC, and revealing the known limitations of direct conversion material (flux limitation, polarization behavior). Measurements with g- and X-rays are compared with simulation results, and good correspondence is obtained.