•The market analysis of Swedish PV/T industry is conducted.•An analytical model is developed for economic evaluation of a PV/T concentrator in Sweden.•Sensitivities of 11 key input variables to 3 ...economic-performance metrics is analysed.•Essential influencing variables are optimized for recommendations of PV/T investment in Sweden.
The solar energy share in Sweden will grow up significantly in next a few decades. Such transition offers not only great opportunity but also uncertainties for the emerging solar photovoltaic/thermal (PV/T) technologies. This paper therefore aims to conduct a techno-economic evaluation of a reference solar PV/T concentrator in Sweden for building application. An analytical model is developed based on the combinations of Monte Carlo simulation techniques and multi energy-balance/financial equations, which takes into account of the integrated uncertainties and risks of various variables. In the model, 11 essential input variables, i.e. average daily solar irradiance, electrical/thermal efficiency, prices of electricity/heating, operation & management (OM) cost, PV/T capital cost, debt to equity ratio, interest rate, discount rate, and inflation rate, are considered, while the economic evaluation metrics, such as levelized cost of energy (LCOE), net present value (NPV), and payback period (PP), are primarily assessed. According to the analytical results, the mean values of LCOE, NPV and PP of the reference PV/T connector are observed at 1.27 SEK/kW h (0.127 €/kW h), 18,812.55 SEK (1881.255 €) and 10 years during its 25 years lifespan, given the project size at 10.37 m2 and capital cost at 4482–5378 SEK/m2 (448.2–537.8 €/m2). The positive NPV indicates that the investment on the selected PV/T concentrator will be profitable as the projected earnings exceeds the anticipated costs, depending on the NPV decision rule. The sensitivity analysis and the parametric study illustrate that the economic performance of the reference PV/T concentrator in Sweden is mostly proportional to solar irradiance, debt to equity ratio and heating price, but disproportionate to capital cost and discount rate. Together with additional market analysis of PV/T technologies in Sweden, it is expected that this paper could clarify the economic situation of PV/T technologies in Sweden and provide a useful model for their further investment decisions, in order to achieve sustainable and low-carbon economics, with an expanded quantitative discussion of the real economic or policy scenarios that may lead to those outcomes.
Thermal comfort aspects in a room vary with different space heating methods. The main focus in this study was how different heating systems and their position affect the indoor climate in an ...exhaust-ventilated office under Swedish winter conditions. The heat emitters used were a high and a medium–high temperature radiator, a floor heating system and large wall heating surfaces at low temperature. Computational fluid dynamics (CFD) simulations were used to investigate possible cold draught problems, differences in vertical temperature gradients, air speed levels and energy consumption. Two office rooms with different ventilation systems and heating needs were evaluated. Both systems had high air exchange rates and cold infiltration air.
The general conclusions from this study were that low temperature heating systems may improve indoor climate, giving lower air speeds and lower temperature differences in the room than a conventional high temperature radiator system. The disadvantage with low temperature systems is a weakness in counteracting cold down-flow from ventilation supply units. For that reason the location of heat emitters and the design of ventilation systems proved to be of particular importance. Measurements performed in a test chamber were used to validate the results from the CFD simulations.
The European Union (EU) has implemented several policies to enhance energy efficiency. Among these policies is the objective of achieving energy-efficient renovations in at least 3% of EU buildings ...annually. The primary aim of this study was to offer a precise environmental comparison among four similar district-heated multifamily buildings that have undergone identical energy efficiency measures. The key distinguishing factor among them lies in the HVAC systems installed. The chosen systems were as follows: (1) exhaust ventilation with air pressure control; (2) mechanical ventilation with heat recovery; (3) exhaust ventilation with an exhaust air heat pump; and (4) exhaust ventilation with an exhaust air heat pump with a Photovoltaic (PV) panel. This study involved a life cycle assessment that relied on actual material data from the housing company and energy consumption measurements. This study covered a period of 50 years for thorough analysis. A sensitivity analysis was also conducted to account for various future scenarios of energy production. The findings revealed that the building with an exhaust air heat pump exhibited the lowest greenhouse gas emissions and the shortest carbon payback period (GBPT), needing only around 7 years. In contrast, the building with exhaust ventilation without heat recovery showed the highest emissions and the longest carbon payback period (GBPT), requiring approximately 11 years. Notably, the results were significantly influenced by future scenarios of energy production, emphasizing the crucial role of emission factors in determining the environmental performance of distinct renovation scenarios.
•Energy saving measures can be cost-effective as part of a planned renovation.•Primary energy consumption, non-renewable energy consumption and CO2 emissions are assessed for different electricity ...mixes.•EAHP can be a cost-effective and environmentally beneficial complement to district heating.•EAHP has lower LCC and significantly shorter payback time than ventilation with heat recovery.•Low-temperature ventilation radiators improve the COP of the heat pump.
Renovation of existing buildings is important in the work toward increased energy efficiency and reduced environmental impact. The present paper treats energy renovation measures for a Swedish district heated multi-family house, evaluated through dynamic simulation. Insulation of roof and façade, better insulating windows and flow-reducing water taps, in combination with different HVAC systems for recovery of heat from exhaust air, were assessed in terms of life cycle cost, discounted payback period, primary energy consumption, CO2 emissions and non-renewable energy consumption. The HVAC systems were based on the existing district heating substation and included mechanical ventilation with heat recovery and different configurations of exhaust air heat pump.
Compared to a renovation without energy saving measures, the combination of new windows, insulation, flow-reducing taps and an exhaust air a heat pump gave up to 24% lower life cycle cost. Adding insulation on roof and façade, the primary energy consumption was reduced by up to 58%, CO2 emissions up to 65% and non-renewable energy consumption up to 56%. Ventilation with heat recovery also reduced the environmental impact but was not economically profitable in the studied cases. With a margin perspective on electricity consumption, the environmental impact of installing heat pumps or air heat recovery in district heated houses is increased. Low-temperature heating improved the seasonal performance factor of the heat pump by up to 11% and reduced the environmental impact.
In this study, we critically examine the potential of recycled construction materials, focusing on how these materials can significantly reduce greenhouse gas (GHG) emissions and energy usage in the ...construction sector. By adopting an integrated approach that combines Life Cycle Assessment (LCA) and Material Flow Analysis (MFA) within the circular economy framework, we thoroughly examine the lifecycle environmental performance of these materials. Our findings reveal a promising future where incorporating recycled materials in construction can significantly lower GHG emissions and conserve energy. This underscores their crucial role in advancing sustainable construction practices. Moreover, our study emphasizes the need for robust regulatory frameworks and technological innovations to enhance the adoption of environmentally responsible practices. We encourage policymakers, industry stakeholders, and the academic community to collaborate and promote the adoption of a circular economy strategy in the building sector. Our research contributes to the ongoing discussion on sustainable construction, offering evidence-based insights that can inform future policies and initiatives to improve environmental stewardship in the construction industry. This study aligns with the European Union’s objectives of achieving climate-neutral cities by 2030 and the United Nations’ Sustainable Development Goals outlined for completion by 2030. Overall, this paper contributes to the ongoing dialogue on sustainable construction, providing a fact-driven basis for future policy and initiatives to enhance environmental stewardship in the industry.
A common way of calculating the life cycle cost (LCC) of building renovation measures is to approach it from the building side, where the energy system is considered by calculating the savings in the ...form of less bought energy. In this study a wider perspective is introduced. The LCC for three different energy renovation measures, mechanical ventilation with heat recovery and two different heat pump systems, are compared to a reference case, a building connected to the district heating system. The energy system supplying the building is assumed to be 100% renewable, where eight different future scenarios are considered. The LCC is calculated as the total cost for the renovation measures and the energy systems. All renovation measures result in a lower district heating demand, at the expense of an increased electricity demand. All renovation measures also result in an increased LCC, compared to the reference building. When aiming for a transformation towards a 100% renewable system in the future, this study shows the importance of having a system perspective, and also taking possible future production scenarios into consideration when evaluating building renovation measures that are carried out today, but will last for several years, in which the energy production system, hopefully, will change.
A ventilation radiator is a combined ventilation and heat emission unit currently of interest due to its potential for increasing energy efficiency in exhaust-ventilated buildings with warm water ...heating. This paper presents results of performance tests of several ventilation radiator models conducted under controlled laboratory conditions.
The purpose of the study was to validate results achieved by Computational Fluid Dynamics (CFD) in an earlier study and identify possible improvements in the performance of such systems. The main focus was on heat transfer from internal convection fins, but comfort and health aspects related to ventilation rates and air temperatures were also considered.
The general results from the CFD simulations were confirmed; the heat output of ventilation radiators may be improved by at least 20% without sacrificing ventilation efficiency or thermal comfort.
Improved thermal efficiency of ventilation radiators allows a lower supply water temperature and energy savings both for heating up and distribution of warm water in heat pumps or district heating systems. A secondary benefit is that a high ventilation rate can be maintained all year around without risk for cold draught.
► Low temperature heat emitters are currently of interest due to their potential for increasing energy efficiency. ► A ventilation radiator is a combined ventilation and heat emission unit which can be adapted to low temperature heating systems. ► We examine how ventilation radiators can be made to be more efficient in terms of energy consumption and thermal comfort. ► Current work focuses on heat transfer mechanisms and convection fin configuration of ventilation radiators.
Performance of heat emitters in a room is affected by their interaction with the ventilation system. A radiator gives more heat output with increased air flow along its heat transferring surface, and ...with increased thermal difference to surrounding air. Radiator heat output and comfort temperatures in a small one-person office were studied using different positions for the ventilation air inlet. In two of the four test cases the air inlet was placed between radiator panels to form ventilation-radiator systems. Investigations were made by CFD (Computational Fluid Dynamics) simulations, and included visualisation of thermal comfort conditions, as well as radiator heat output comparisons. The room model was exhaust-ventilated, with an air exchange rate equal to what is recommended for Swedish offices (7
l
s
−1 per person) and cold infiltration air (−5
°C) typical of a winter day in Stockholm.
Results showed that under these conditions ventilation-radiators were able to create a more stable thermal climate than the traditional radiator ventilation arrangements. In addition, when using ventilation-radiators the desired thermal climate could be achieved with a radiator surface temperature as much as 7.8
°C lower. It was concluded that in exhaust-ventilated office rooms, ventilation-radiators can provide energy and environmental savings.
There are different views on whether district heating (DH) or heat pumps (HPs) is or are the best heating solution in order to reach a 100% renewable energy system. This article investigates the ...economic perspective, by calculating and comparing the energy system life cycle cost (LCC) for the two solutions in areas with detached houses. The LCC is calculated using Monte Carlo simulation, where all input data is varied according to predefined probability distributions. In addition to the parameter variations, 16 different scenarios are evaluated regarding the main fuel for the DH, the percentage of combined heat and power (CHP), the DH temperature level, and the type of electrical backup power. Although HP is the case with the lowest LCC for most of the scenarios, there are alternatives for each scenario in which either HP or DH has the lowest LCC. In alternative scenarios with additional electricity transmission costs, and a marginal cost perspective regarding the CHP investment, DH has the lowest LCC overall, taking into account all scenarios. The study concludes that the decision based on energy system economy on whether DH should expand into areas with detached houses must take local conditions into consideration.