Beam test of FARICH prototype with digital photon counter Barnyakov, A.Yu; Barnyakov, M.Yu; Bobrovnikov, V.S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Letnik:
732
Journal Article
Recenzirano
In June 2012 we tested a Focusing Aerogel RICH detector prototype based on Digital Photon Counters (DPC) by Philips at the CERN PS T10 beam line with a particle momentum up to 6GeV/c. The prototype ...comprises a 20×20cm2 photon detector with 48×48 DPC pixels. In order to reduce the dark count rate, the photon detector was cooled to −40°C in addition to disabling individual DPC's microcells. A four layer focusing aerogel radiator with 200mm focal distance was studied. We obtained a Cherenkov angle resolution of 3.61±0.04mrad. The mean number of photoelectrons in a ring is 12. Directly measured π/K separation at 6GeV/c momentum is 3.5σ, μ/π separation is 5.3σ at 1GeV/c. A comparison with a Monte Carlo simulation is presented as well.
•Focusing Aerogel RICH prototype with Digital Photon Counters by Philips was built.•The prototype was tested at the CERN PS T10 beam line.•We observed Cherenkov rings with 12 photoelectrons in average.•Timing resolution of DPCs is 48ps for single photons.•Cherenkov angle resolution is 3.64±0.04mrad per ring.
Aerogel for FARICH detector Barnyakov, A.Yu; Barnyakov, M.Yu; Bobrovnikov, V.S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2014, Letnik:
766
Journal Article
Recenzirano
We present our current experience in preparation of focusing aerogels for the Focusing Aerogel RICH detector. Multilayer focusing aerogel tiles have been produced in Novosibirsk by a collaboration of ...the Budker Institute of Nuclear Physics and Boreskov Institute of Catalysis since 2004. We have obtained 2-3-4-layer blocks with the thickness of 30-45 mm. In 2012, the first samples of focusing blocks with continuous density (refractive index) gradient along thickness were produced. This technology can significantly reduce the contribution from the geometric factor of the radiator thickness to the resolution of the measured Cherenkov angle in the FARICH detector. The special installation was used for automatic control of reagents ratio during the synthesis process. The first samples were tested using the digital radiography method and on the electron beam with the FARICH prototype.
Searches for lepton-flavor-violating decays of a tau lepton to a lighter mass lepton and a photon have been performed with the entire data set of (963+/-7)x10{6} tau decays collected by the BABAR ...detector near the Upsilon(4S), Upsilon(3S) and Upsilon(2S) resonances. The searches yield no evidence of signals and we set upper limits on the branching fractions of B(tau{+/-}-->e{+/-}gamma)<3.3x10{-8} and B(tau{+/-}-->mu{+/-}gamma)<4.4x10{-8} at 90% confidence level.
The cross section for the process
e
+
e
−
→
ηK
+
K
−
wasmeasured at c.m. energies in the range between 1.56 and 2.00 GeV in an experiment with the SND detector at the VEPP-2000
e
+
e
−
collider. The ...invariant-mass distribution of kaon pairs is consistent with the hypothesis that the transition through the
ηφ
intermediate state makes a dominant contribution to the transition in question.
Particle identification system based on dense aerogel Barnyakov, A.Yu; Barnyakov, M.Yu; Beloborodov, K.I. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Letnik:
732
Journal Article
Recenzirano
A threshold Cherenkov counter based on dense aerogel with refraction index n=1.13 is described. This counter is used for kaon identification at momenta below 1GeV/c in the SND detector, which takes ...data at the VEPP-2000 e+e− collider. The results of measurements of the counter efficiency using electrons, muons, pions, and kaons produced in e+e− annihilation are presented.
The Super Charm–Tau (SCT) Factory is a proposed electron–positron collider in Novosibirsk with a peak luminosity of 1035cm−1s−1 operating in the energy range between 2and 6 GeV. The interaction ...region should be equipped by an excellent universal particle detector meeting the requirements of broad physics program of the experiment. Research and development for all detector subsystems is currently underway. Particle identification (PID) system of the detector is required to provide the state-of-the-art level of μ/π separation for the particle momenta up to 1.2GeV∕c. The following options for the PID system are considered in this paper: focusing aerogel ring imaging Cherenkov (FARICH) detector composed of 4-layer aerogel tiles, threshold Cherenkov counters based on aerogel shifter photomultiplier (ASHIPH), and time-of-flight (ToF) detector combined with the time-of-propagation (ToP) approach providing a time resolution better than 30ps. Assessment of the charged particle separation performance for these options based on simulation and prototype tests results is presented.
Operation and performance of the ASHIPH counters at the KEDR detector Barnyakov, A.Yu; Barnyakov, M.Yu; Boborovnikov, V.S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
07/2016, Letnik:
824
Journal Article
Recenzirano
In 2014 the fully installed ASHIPH (Aerogel, SHifter, PHotomultiplier) system began its operation in the KEDR experiment at the VEPP-4M e+e−-collider. The system contains 1000liters of aerogel with ...refractive index n=1.05 in 160 counters that are arranged in two layers. Cherenkov light collection is preformed by means of wavelength shifters (WLS). 160Micro-Channel Plate (MCP) PMTs with multialkali photocathode are used as photodetectors. Efficiency of relativistic particles detection was measured with e+e−→e+e− events and cosmic muons. Detection efficiency for under-threshold particles was measured with cosmic muons. From these data π/K-separation of 4σ at the momentum 1.2GeV/c was obtained.
Aerogel for different types of Cherenkov detectors is produced by a collaboration of Budker Institute of Nuclear Physics and Boreskov Institute of Catalysis during more than two decades. So far only ...the production of two sizes was possible in large numbers: 50 × 50 and 115 × 115mm2. This work is devoted to the development of the production technology of large scale aerogel radiators for use in the Ring-imaging Cherenkov (RICH) detectors. These detectors require additional parameters to be controlled for each aerogel tile during production. Procedures of measurement of the aerogel tiles refractive index, the light scattering length, the upper surface flatness are described.
In an experiment with the SND detector at the VEPP-2000
collider, the cross sections for the processes
and
were measured at collision energies of
GeV in the center-of-mass frame. The results agree ...with the results of earlier measurements in the BABAR experiment and have a commensurate precision.
PID system based on focusing aerogel RICH for the super C-τ factory Barnyakov, A.Yu; Barnyakov, M.Yu; Boborovnikov, V.S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2020, Letnik:
952
Journal Article
Recenzirano
A high performance particle identification (PID) system is essential for the successful realization of the broad physics program at the future Super C-τ Factory in Novosibirsk. The main requirements ...for the PID system are as follows: good π/K-separation in the entire operational momentum range and good μ∕π-separation in the momentum range from 0.3 to 1.2 GeV/c. The RICH detector based on focusing aerogel radiator (FARICH) and position-sensitive photon detector meets all these requirements. The FARICH method is described, and the beam test results are presented. The FARICH system design outline for the Super C-τ Factory project is presented. Most promising photon detector options are considered.