Accurate predictions of species distributions are essential for climate change impact assessments. However the standard practice of using long-term climate averages to train species distribution ...models might mute important temporal patterns of species distribution. The benefit of using temporally explicit weather and distribution data has not been assessed. We hypothesized that short-term weather associated with the time a species was recorded should be superior to long-term climate measures for predicting distributions of mobile species.
We tested our hypothesis by generating distribution models for 157 bird species found in Australian tropical savannas (ATS) using modelling algorithm Maxent. The variable weather of the ATS supports a bird assemblage with variable movement patterns and a high incidence of nomadism. We developed "weather" models by relating climatic variables (mean temperature, rainfall, rainfall seasonality and temperature seasonality) from the three month, six month and one year period preceding each bird record over a 58 year period (1950-2008). These weather models were compared against models built using long-term (30 year) averages of the same climatic variables.
Weather models consistently achieved higher model scores than climate models, particularly for wide-ranging, nomadic and desert species. Climate models predicted larger range areas for species, whereas weather models quantified fluctuations in habitat suitability across months, seasons and years. Models based on long-term climate averages over-estimate availability of suitable habitat and species' climatic tolerances, masking species potential vulnerability to climate change. Our results demonstrate that dynamic approaches to distribution modelling, such as incorporating organism-appropriate temporal scales, improves understanding of species distributions.
Irritable bowel syndrome (IBS) is a heterogeneous condition and defined according to symptoms. Low-grade inflammation has been associated with IBS, particularly that following infection, but whether ...altered intestinal permeability profiles relate to irritable bowel subtype or onset is uncertain. Our aim was to compare small and large intestinal permeability in various subtypes of IBS to healthy controls.
Intestinal permeability was measured using 1.8 MBq of 51Cr-EDTA and collecting urine over 24 h; Study 1: patients with diarrhea-predominant postinfectious IBS (N=15), constipation-predominant IBS (N=15), and healthy controls (N=15); Study 2: two groups of diarrhea-predominant IBS (D-IBS), one with a history of onset after acute gastroenteritis (postinfectious) (N=15) and the other without such a history (nonpostinfectious) (N=15) both compared with healthy controls (N=12).
Permeability expressed as percentage of total dose excreted in urine (median inter-quartile range). Study 1: Proximal small intestinal permeability was increased in postinfectious IBS (0.19 0.12-0.23) in contrast to constipated IBS (0.085 0.043-0.13) and controls (0.07 0.035-0.19) (p=0.02). IBS patients with eczema, asthma, or hayfever had increased proximal small intestinal permeability compared with IBS patients without atopy (p=0.02). Study 2: Small intestinal permeability was greater in nonpostinfectious diarrhea-predominant IBS (0.84 0.69-1.49) compared with postinfectious IBS (0.43 0.29-0.63, p=0.028) or controls (0.27 0.2-0.39), p=0.001).
Small intestinal permeability is frequently abnormal in diarrhea-predominant IBS. Those without a history of infectious onset appear to have a more severe defect.
Acute myeloid leukemia (AML) is a malignancy of immature progenitor cells. AML differentiation therapies trigger leukemia maturation and can induce remission, but relapse is prevalent and its ...cellular origin is unclear. Here we describe high resolution analysis of differentiation therapy response and relapse in a mouse AML model. Triggering leukemia differentiation in this model invariably produces two phenotypically distinct mature myeloid lineages in vivo. Leukemia-derived neutrophils dominate the initial wave of leukemia differentiation but clear rapidly and do not contribute to residual disease. In contrast, a therapy-induced population of mature AML-derived eosinophil-like cells persists during remission, often in extramedullary organs. Using genetic approaches we show that restricting therapy-induced leukemia maturation to the short-lived neutrophil lineage markedly reduces relapse rates and can yield cure. These results indicate that relapse can originate from therapy-resistant mature AML cells, and suggest differentiation therapy combined with targeted eradication of mature leukemia-derived lineages may improve disease outcome.
Inertial measurement units (IMUs) offer an attractive way to study human lower-limb kinematics without traditional laboratory constraints. We present an error-state Kalman filter method to estimate ...3D joint angles, joint angle ranges of motion, stride length, and step width using data from an array of seven body-worn IMUs. Importantly, this paper contributes a novel joint axis measurement correction that reduces joint angle drift errors without assumptions of strict hinge-like joint behaviors of the hip and knee. We evaluate the method compared to two optical motion capture methods on twenty human subjects performing six different types of walking gait consisting of forward walking (at three speeds), backward walking, and lateral walking (left and right). For all gaits, RMS differences in joint angle estimates generally remain below 5 degrees for all three ankle joint angles and for flexion/extension and abduction/adduction of the hips and knees when compared to estimates from reflective markers on the IMUs. Additionally, mean RMS differences in estimated stride length and step width remain below 0.13 m for all gait types, except stride length during slow walking. This study confirms the method’s potential for non-laboratory based gait analysis, motivating further evaluation with IMU-only measurements and pathological gaits.
While balance training with concurrent feedback has been shown to improve real-time balance in older adults, terminal feedback may simplify implementation outside of clinical settings. Similarly, ...visual feedback is particularly well-suited for use outside the clinic as it is relatively easily understood and accessible via ubiquitous mobile devices (e.g., smartphones) with little additional peripheral equipment. However, differences in the effects of concurrent and terminal visual feedback are not yet well understood. We therefore performed a pilot study that directly compared the immediate effects of concurrent and terminal visual feedback as a first and necessary step in the future design of visual feedback technologies for balance training outside of clinical settings. Nineteen healthy older adults participated in a single balance training session during which they performed 38 trials of a single balance exercise including trials with concurrent, terminal or no visual feedback. Analysis of trunk angular position and velocity features recorded via an inertial measurement unit indicated that sway angles decreased with training regardless of feedback type, but sway velocity increased with concurrent feedback and decreased with terminal feedback. After removing feedback, training with either feedback type yielded decreased mean velocity, but only terminal feedback yielded decreased sway angles. Consequently, this study suggests that, for older adults, terminal visual feedback may be a viable alternative to concurrent visual feedback for short duration single-task balance training. Terminal feedback provided using ubiquitous devices should be further explored for balance training outside of clinical settings.
Baseball and softball pitch types are distinguished by the path and speed of the ball which, in turn, are determined by the angular velocity of the ball and the velocity of the ball center at the ...instant of release from the pitcher’s hand. While radar guns and video-based motion capture (mocap) resolve ball speed, they provide little information about how the angular velocity of the ball and the velocity of the ball center develop and change during the throwing motion. Moreover, mocap requires measurements in a controlled lab environment and by a skilled technician. This study addresses these shortcomings by introducing a highly miniaturized, wireless inertial measurement unit (IMU) that is embedded in both baseballs and softballs. The resulting “ball-embedded” sensor resolves ball dynamics right on the field of play. Experimental results from ten pitches, five thrown by one softball pitcher and five by one baseball pitcher, demonstrate that this sensor technology can deduce the magnitude and direction of the ball’s velocity at release to within 4.6% of measurements made using standard mocap. Moreover, the IMU directly measures the angular velocity of the ball, which further enables the analysis of different pitch types.
Three-dimensional rotations across the human knee serve as important markers of knee health and performance in multiple contexts including human mobility, worker safety and health, athletic ...performance, and warfighter performance. While knee rotations can be estimated using optical motion capture, that method is largely limited to the laboratory and small capture volumes. These limitations may be overcome by deploying wearable inertial measurement units (IMUs). The objective of this study is to present a new IMU-based method for estimating 3D knee rotations and to benchmark the accuracy of the results using an instrumented mechanical linkage. The method employs data from shank- and thigh-mounted IMUs and a vector constraint for the medial-lateral axis of the knee during periods when the knee joint functions predominantly as a hinge. The method is carefully validated using data from high precision optical encoders in a mechanism that replicates 3D knee rotations spanning (1) pure flexion/extension, (2) pure internal/external rotation, (3) pure abduction/adduction, and (4) combinations of all three rotations. Regardless of the movement type, the IMU-derived estimates of 3D knee rotations replicate the truth data with high confidence (RMS error < 4 ° and correlation coefficient r ≥ 0.94 ).
The application of environmental DNA (eDNA) metabarcoding as a biomonitoring tool has greatly increased, but studies have focused on temperate aquatic macro‐organisms. We apply eDNA metabarcoding to ...detecting the mammalian community in two high‐biodiversity regions of Brazil: the Amazon and Atlantic Forests. We identified Critically Endangered and Endangered mammalian species and found overlap with species identified via camera trapping. We highlight the potential for using eDNA monitoring for mammals in biodiverse regions and identify challenges: we need a better understanding of the ecology of eDNA within variable environments and more appropriate reference sequences for species identification in these anthropogenically impacted biomes.
Mammalian families (shown with stylised drawings of representative species within hexagons) identified from environmental DNA samples in the Amazon and Atlantic Forests of Brazil. Water and sediment samples were taken from rivers (‘Meeting of the Waters’; top left) and streams (bottom left and right) and subjected to DNA metabarcoding analyses using mammal‐specific primers. A total of 28 molecular operational taxonomic units (MOTUs) were identified, and 13 of these could be identified to species level. This case study has highlighted the potential of this non‐invasive genetic technique to detect (and potentially monitor) terrestrial and aquatic mammals in these biodiverse Neotropical regions.
This study introduces a new method to understand how added load affects human performance across a broad range of athletic tasks (ten obstacles) embedded in an outdoor obstacle course. The method ...employs an array of wearable inertial measurement units (IMUs) to wirelessly record the movements of major body segments to derive obstacle-specific metrics of performance. The effects of load are demonstrated on (N = 22) participants who each complete the obstacle course under four conditions including unloaded (twice) and with loads of 15% and 30% of their body weight (a total of 88 trials across the group of participants). The IMU-derived performance metrics reveal marked degradations in performance with increasing load across eight of the ten obstacles. Overall, this study demonstrates the significant potential in using this wearable technology to evaluate human performance across multiple tasks and, simultaneously, the adverse effects of body-borne loads on performance. The study addresses a major need of military organizations worldwide that frequently employ standardized obstacle courses to understand how added loads influence warfighter performance. Importantly, the findings and conclusions drawn from IMU data would not be possible using traditional timing metrics used to evaluate task performance.
MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements ...by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean ± SD coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 ± 2% at large gastric volumes (>200 ml). Mean ± SD secretion volumes post meal ingestion were 64 ± 51 ml and 110 ± 40 ml at 15 and 75 min, respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient ± std err of 1.06 ± 0.10 and intercept −11 ± 24 ml. In conclusion, (i) rapid volume acquisition and respiratory triggered T1 mapping removed the requirement to image during prolonged breath-holds (ii) semi-automatic analysis greatly reduced the time required to derive measurements and (iii) correction for secretion volumes provided accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice.