This study sought to evaluate the trends in isolated surgical aortic valve replacement (SAVR) procedures across hospitals with different transcatheter aortic valve replacement (TAVR) volumes among ...Medicare beneficiaries.
The volume of TAVR has increased in the United States since its approval, now exceeding that of isolated SAVR.
Hospitalizations of adults (≥18 years of age) with International Classification of Diseases-9th Revision-Clinical Modification procedure codes for SAVR (35.21 or 35.22) or TAVR (35.05 or 35.06) who were included in the Medicare Provider Analysis and Review database between January 1, 2011, and December 31, 2014, were included. Trends in isolated SAVR patient characteristics, procedural volumes, and outcomes by quartile (Q) of hospital-level TAVR use were assessed over the study period.
A total of 37,705 isolated SAVR procedures were analyzed for the study. The annual volume of isolated SAVR procedures decreased in hospitals performing the largest number of TAVR procedures (Q3: 1,557 in 2011 to 1,391 in 2014; and Q4: 2,607 in 2011 to 1,791 in 2014). Thirty-day and 1-year mortality after SAVR also declined over the study period in hospitals with the largest TAVR volume (annual change rate in mortality for Q3: −16.4%; p < 0.001; Q4: −20.8%; p < 0.001).
The advent of TAVR was associated with a reduction in isolated SAVR volumes, a decrease in comorbidities among patients undergoing SAVR, and corresponding reductions in observed short- and long-term SAVR mortality among hospitals performing the greatest number of TAVRs.
Display omitted
A plethora of catheter-based strategies have been developed to treat mitral valve disease. Evolving 3-dimensional (3D) multidetector computed tomography (MDCT) technology can accurately reconstruct ...the mitral valve by means of 3-dimensional computational modeling (3DCM) to allow virtual implantation of catheter-based devices. 3D printing complements computational modeling and offers implanting physician teams the opportunity to evaluate devices in life-size replicas of patient-specific cardiac anatomy. MDCT-derived 3D computational and 3D-printed modeling provides unprecedented insights to facilitate hands-on procedural planning, device training, and retrospective procedural evaluation. This overview summarizes current concepts and provides insight into the application of MDCT-derived 3DCM and 3D printing for the planning of transcatheter mitral valve replacement and closure of paravalvular leaks. Additionally, future directions in the development of 3DCM will be discussed.
Display omitted
•Catheter-based interventions for complex defects of the mitral valve apparatus are evolving.•MDCT-derived 3D computational modeling and 3D printing enhance risk evaluation and planning of complex transcatheter procedures.•Incorporation of multiple cardiac phases, tissue/device properties, and hemodynamics should optimize 3D modeling.
This analysis evaluates the relationship of annular size to hemodynamics and the incidence of prosthesis-patient mismatch (PPM) in surgical aortic valve replacement (SAVR) and transcatheter aortic ...valve replacement (TAVR) patients.
The CoreValve US Pivotal High Risk Trial, described previously, compared TAVR using a self-expanding valve with SAVR. Multislice computed tomography was used to categorize TAVR and SAVR subjects according to annular perimeter-derived diameter: large (≥26 mm), medium (23 to <26 mm), and small (<23 mm). Hemodynamics, PPM, and clinical outcomes were assessed.
At all postprocedure visits, mean gradients were significantly lower for TAVR compared with SAVR in small and medium size annuli (p < 0.001). Annular size was significantly associated with mean gradient after SAVR, with small annuli having the highest gradients (p < 0.05 at all timepoints); gradients were similar across all annular sizes after TAVR. In subjects receiving SAVR, the frequency of PPM was significantly associated with annular size, with small annuli having the greatest incidence. No difference in PPM incidence by annular sizing was observed with TAVR. In addition, TAVR subjects had significantly less PPM than SAVR subjects in small and medium annuli (p < 0.001), with no difference in the incidence of PPM between TAVR and SAVR in large annuli (p = 0.10).
Annular size has a significant effect on hemodynamics and the incidence of PPM in SAVR subjects, not observed in TAVR subjects. With respect to annular size, TAVR results in better hemodynamics and less PPM for annuli less than 26 mm and should be strongly considered when choosing a tissue valve for small and medium size annuli.
Background Prospectively collected frailty markers are associated with an incremental 1-year mortality risk after transcatheter aortic valve replacement (TAVR) compared with comorbidities alone. ...Whether information on frailty markers captured retrospectively in administrative billing data is similarly predictive of long-term mortality after TAVR is unknown. We sought to characterize the prognostic importance of frailty factors as identified in healthcare billing records in comparison to validated measures of frailty for the prediction of long-term mortality after TAVR. Methods and Results Adult patients undergoing TAVR between August 25, 2011, and September 29, 2015, were identified among Medicare fee-for-service beneficiaries. The Johns Hopkins Claims-based Frailty Indicator was used to identify frail patients. We used nested Cox regression models to identify claims-based predictors of mortality up to 4 years post-procedure. Four groups of variables, including cardiac risk factors, noncardiac risk factors, patient procedural risk factors, and nontraditional markers of frailty, were introduced sequentially, and their integrated discrimination improvement was assessed. A total of 52 338 TAVR patients from 558 clinical sites were identified, with a mean follow-up time period of 16 months. In total, 14 174 (27.1%) patients died within the study period. The mortality rate was 53.9% at 4 years post-TAVR. A total of 34 863 (66.6%) patients were defined as frail. The discrimination of each of the 4 models was 0.60 (95% CI, 0.59-60), 0.65 (95% CI, 0.64-0.65), 0.68 (95% CI, 0.67-0.68), and 0.70 (95% CI, 0.69-0.70), respectively. The addition of nontraditional frailty markers as identified in claims improved mortality prediction above and beyond traditional risk factors (integrated discrimination improvement: 0.019; P<0.001). Conclusions Risk prediction models that include frailty as identified in claims data can be used to predict long-term mortality risk after TAVR. Linkage to claims data may allow enhanced mortality risk prediction for studies that do not collect information on frailty.
Contemporary practices for hemodynamically supported high-risk percutaneous coronary intervention have evolved over the last decade. This study sought to compare outcomes of the prospective, ...multicenter, PROTECT III study to historic patients treated with Impella in the PROTECT II randomized controlled trial.
Of 1,134 patients enrolled in PROTECT III from March 2017 to March 2020, 504 were “PROTECT II-like” (met eligibility for PROTECT II randomized controlled trial) and are referred to as PROTECT III for comparative analysis. Major adverse cardiac and cerebrovascular events (MACCE), comprising all-cause mortality, stroke/transient ischemic attack, myocardial infarction, and repeat revascularization, were compared at hospital discharge and 90 days.
Compared with PROTECT II (N = 216), PROTECT III patients were less often Caucasian (77.1% vs 83.8%, P = .045), with less prior CABG (13.7% vs 39.4%; P < .001) and prior myocardial infarction (40.7% vs 69.3%; P < .001). More PROTECT III patients underwent rotational atherectomy (37.1% vs 14.8%, P < .001) and duration of support was longer (median 1.6 vs 1.3 hours; p<0.001), with greater improvement achieved in myocardial ischemia jeopardy scores (7.0±2.4 vs 4.4±2.9; P < .001) and SYNTAX scores (21.4±10.8 vs 15.7±9.5; P < .001). In-hospital bleeding requiring transfusion was significantly lower in PROTECT III (1.8% vs 9.3%; P < .001), as was procedural hypotension (2.2% vs 10.1%; P < .001) and cardiopulmonary resuscitation or ventricular arrhythmia (1.6% vs 6.9%; P < .001). At 90 days, MACCE was 15.1% and 21.9% in PROTECT III and PROTECT II, respectively (p=0.037). Following propensity score matching, Kaplan-Meier analysis showed improved 90-day MACCE rates in PROTECT III (10.4% vs 16.9%, P = .048).
The PROTECT III study demonstrates improved completeness of revascularization, less bleeding, and improved 90-day clinical outcomes compared to PROTECT II for Impella-supported high-risk percutaneous coronary intervention among patients with severely depressed LVEF.
Objective The Carotid Revascularization Endarterectomy versus Stenting Trial (CREST) demonstrated a higher periprocedural stroke and death (S+D) rate among patients randomized to carotid artery ...stenting (CAS) than to carotid endarterectomy (CEA). Herein, we seek factors that affect the CAS-CEA treatment differences and potentially to identify a subgroup of patients for whom CAS and CEA have equivalent periprocedural S+D risk. Methods Patient and arterial characteristics were assessed as effect modifiers of the CAS-CEA treatment difference in 2502 patients by the addition of factor-by-treatment interaction terms to a logistic regression model. Results Lesion length and lesions that were contiguous or were sequential and noncontiguous extending remote from the bulb were identified as influencing the CAS-to-CEA S+D treatment difference. For those with longer lesion length (≥12.85 mm), the risk of CAS was higher than that of CEA (odds ratio OR, 3.42; 95% confidence interval CI, 1.19-9.78). Among patients with sequential or remote lesions extending beyond the bulb, the risk for S+D was higher for CAS relative to CEA (OR, 9.01; 95% CI, 1.20-67.8). For the 37% of patients with lesions that were both short and contiguous, the odds of S+D in those treated with CAS was nonsignificantly 28% lower than for CEA (OR, 0.72; 95% CI, 0.21-2.46). Conclusions The higher S+D risk for those treated with CAS appears to be largely isolated to those with longer lesion length and/or those with sequential and remote lesions. In the absence of those lesion characteristics, CAS appears to be as safe as CEA with regard to periprocedural risk of S+D.
For patients with severe aortic stenosis (AS) at extreme surgical risk, transcatheter aortic valve replacement (TAVR) leads to improved survival and health status when compared with medical therapy. ...Whether the early health status benefits of TAVR in these patients are sustained beyond 1 year of follow-up is unknown.
Six hundred thirty-nine patients with severe AS at extreme surgical risk underwent TAVR in the CoreValve US Extreme Risk Pivotal trial. Health status was evaluated at baseline and at 1, 6, 12, 24, and 36 months using the Kansas City Cardiomyopathy Questionnaire (KCCQ), the Short-Form-12, and the EuroQoL-5D. Analyses were performed using pattern mixture models to account for both death and missing data and were stratified by iliofemoral (IF) and non-iliofemoral (non-IF) access. After TAVR, there was substantial health status improvement in disease-specific and generic scales by 6 to 12 months. Although there were small declines in health status after 12 months, the initial benefits of TAVR were largely sustained through 3 years for both IF and non-IF cohorts (change from baseline in KCCQ Overall Summary score 19.0 points in IF patients and 14.9 points in non-IF patients; P<.01 for both comparisons). Among surviving patients, clinically meaningful (≥10 point) improvements in the KCCQ Overall Summary Score at 3 years were observed in 85.0% and 83.4% of IF and non-IF patients respectively.
Among extreme risk patients with severe AS, TAVR resulted in large initial health status benefits that were sustained through 3-year follow-up. Although late mortality was high in this population, these findings demonstrate that TAVR offers substantial and durable health status improvements for surviving patients.
•Transcatheter aortic valve replacement appears to be beneficial in symptomatic patients with less than severe aortic stenosis.•Transcatheter aortic valve replacement showed improved 1-year ...hemodynamics and quality of life metrics.•Randomized trial data are eagerly awaited.
Optimal timing for aortic valve replacement in symptomatic patients with less than severe aortic stenosis (AS) is not well defined. There is limited information on the benefit of valve replacement in these patients. Symptomatic patients with less than severe AS, defined as a mean aortic gradient ≥20 and <40 mm Hg, peak aortic velocity >3 and <4 m/s, and aortic valve area >1.0 and <1.5 cm2, enrolled in the Society for Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy Registry and who underwent attempted supra-annular, self-expanding transcatheter aortic valve replacement (TAVR) were reviewed. Site-reported valve hemodynamics, clinical events, and quality of life metrics were analyzed at 30 days and 1 year after the procedure. A total of 1,067 patients with attempted TAVR (mean age 78.4 ± 8.4 years; Society for Thoracic Surgery score 4.7 ± 3.4%) were found to have symptoms but less than severe AS. From baseline to postprocedure, mean gradient decreased (29.9 ± 4.9 vs 8.4 ± 4.8 mm Hg, p <0.001), and aortic valve area increased (1.2 ± 0.1 vs 2.2 ± 0.7 cm2, p <0.001). Clinical events included 30-day and 1-year all-cause mortality (1.5% and 9.6%), stroke (2.2% and 3.3%), and new pacemaker implantation (18.1% and 20.9%). There were statistically significant improvements in the New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire at 30 days and 1 year. In conclusion, patients with symptomatic but less than severe AS who underwent supra-annular, self-expanding TAVR experienced improved valve hemodynamics and quality of life measures 1 year after the procedure. Randomized studies of TAVR versus a control arm in symptomatic patients with less than severe AS are ongoing.
Gender-Specific Outcomes After Sirolimus-Eluting Stent Implantation Emilia Solinas, Eugenia Nikolsky, Alexandra J. Lansky, Ajay J. Kirtane, Marie-Claude Morice, Jeffrey J. Popma, Joachim Schofer, ...Erick Schampaert, Tereza Pucelikova, Jiro Aoki, Martin Fahy, George D. Dangas, Jeffrey W. Moses, Donald E. Cutlip, Martin B. Leon, Roxana Mehran In this analysis of pooled data from the RAVEL (Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary Revascularization), SIRIUS (SIRolImUS-coated Bx velocity balloon expandable stent in the treatment of patients with de novo coronary artery lesions), E-SIRIUS (Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries), and C-SIRIUS (Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries) trials, sirolimus-eluting stent (SES) versus bare metal-stent (BMS) implantation was associated with significant reductions in rates of in-segment binary restenosis both in women (6.3% vs. 43.8%) and in men (6.4% vs. 35.6%), as well as reductions in adverse clinical outcomes in both genders. By multivariable analysis, female gender was not an independent predictor of restenosis and clinical outcomes in SES- or BMS-treated patients.