Modern optoelectronic devices use the advantage of digital systems for data processing aimed at delivering reliable information. However, since commonly used DACs have limited accuracy, some ...artefacts can be observed in data streams, especially in systems designed for continuous, long-term process monitoring. In this paper, the authors' experience with data enhancement using a fibre-optic rotational seismograph (FORS) operating in a closed-loop mode is presented and discussed. Generally, two kinds of enhancement are described. The first one uses suitable filtering techniques adequate for FORS noise investigation, as well as a suitable data resampling method for transmitted data file size reduction. The second one relates to the artefacts observed during data recording in real time. The recording starting point is triggered when the detected signal exceeds a middle signal level and, therefore, the existence of artefacts generally disturbs the recording process. Although the artefacts are easily recognised by human eyes even at first sight, their automatic elimination is not so easy. In this paper, the authors propose a new concept of signal filtering to solve the above problem.
Starting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering ...application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review includes mechanical, acoustical, electrochemical and optical devices and shows that the last of these types are the most promising. It is shown that optical rotational seismometer based on the ring-laser gyroscope concept is the best for seismological applications, whereas systems based on fiber-optic gyroscopes demonstrate parameters which are also required for engineering applications. Laboratory results of the Fibre-Optic System for Rotational Events & Phenomena Monitoring using a small 1-D shaking table modified to generate rotational excitations are presented. The harmonic and time-history tests demonstrate its usefulness for recording rotational motions with rates up to 0.25 rad/s.
The constant development and miniaturization of MEMS sensors invariably provides new possibilities for their use in health-related and medical applications. The application of MEMS devices in ...posturographic systems allows faster diagnosis and significantly facilitates the work of medical staff. MEMS accelerometers constitute a vital part of such systems, particularly those intended for monitoring patients with imbalance disorders. The correct design of such sensors is crucial for gathering data about patient movement and ensuring the good overall performance of the entire system. This paper presents the design and measurements of a three-axis accelerometer dedicated for use in a device which tracks patient movement. Its main focus is the characterization of the sensor, comparing different designs and evaluating the impact of the packaging and readout circuit integration on sensor operation. Extensive testing and measurements confirm that the designed accelerometer works correctly and allows identifying the best design in terms of sensitivity/stability. Moreover, the response of the proposed sensor as a function of the applied acceleration demonstrates very good linearity only if the readout circuit is integrated in the same package as the MEMS sensor.
Preeclampsia is a pregnancy disorder associated with shallow placentation, forcing placental cells to live in hypoxic conditions. This activates the transcription factor kappa B (NFκB) in maternal ...and placental cells. Although the role of NFκB in preeclampsia is well documented, its mechanism of activation in trophoblastic cells has been never studied. This study investigates the mechanism of NFκB activation in a first trimester trophoblastic cell line (HTR8/SVneo) stimulated by a medium containing serum from preeclamptic (PE) or normotensive (C) women in hypoxic (2% O2) or normoxic (8% O2) conditions. The results indicate that in HTR8/SVneo cells, the most widely studied NFκB pathways, i.e., canonical, non-canonical and atypical, are downregulated in environment PE 2% O2 in comparison to C 8% O2. Therefore, other pathways may be responsible for NFκB activation. One such pathway depends on the activation of NFκB by the p53/RSK1 complex through its phosphorylation at Serine 536 (pNFκB Ser536). The data generated by our study show that inhibition of the p53/RSK1 pathway by p53-targeted siRNA results in a depletion of pNFκB Ser536 in the nucleus, but only in cells incubated with PE serum at 2% O2. Thus, the p53/RSK1 complex might play a critical role in the activation of NFκB in trophoblastic cells and preeclamptic placentas.
Double hit of NEMO gene in preeclampsia Sakowicz, Agata; Pietrucha, Tadeusz; Rybak-Krzyszkowska, Magda ...
PloS one,
06/2017, Letnik:
12, Številka:
6
Journal Article
Recenzirano
Odprti dostop
The precise etiology of preeclampsia is unknown. Family studies indicate that both genetic and environmental factors influence its development. One of these factors is NFkB, whose activation depends ...on NEMO (NFkB essential modulator. This is the first study to investigate the association between the existence of single nucleotide variant of the NEMO gene and the appearance of preeclampsia. A total of 151 women (72 preeclamptic women and 79 controls) and their children were examined. Sanger sequencing was performed to identify variants in the NEMO gene in the preeclamptic mothers. The maternal identified variants were then sought in the studied groups of children, and in the maternal and child controls, using RFLP-PCR. Real-time RT-PCR was performed to assess NEMO gene expression in maternal blood, umbilical cord blood and placentas. The sequencing process indicated the existence of two different variants in the 3'UTR region of the NEMO gene of preeclamptic women (IKBKG:c.*368C>A and IKBKG:c.*402C>T). The simultaneous occurrence of the TT genotype in the mother and the TT genotype in the daughter or a T allele in the son increased the risk of preeclampsia development 2.59 fold. Additionally, we found that the configuration of maternal/fetal genotypes (maternal TT/ daughter TT or maternal TT/son T) of IKBKG:c.*402C/T variant is associated with the level of NEMO gene expression. Our results showed that, the simultaneous occurrence of the maternal TT genotype (IKBKG:c.*402C>T variants) and TT genotype in the daughter or T allele in the son correlates with the level of NEMO gene expression and increases the risk of preeclampsia development. Our observations may offer a new insight into the genetic etiology and pathogenesis of preeclampsia.
This paper presents a fall risk assessment approach based on a fast mobility test, automatically evaluated using a low-cost, scalable system for the recording and analysis of body movement. This ...mobility test has never before been investigated as a sole source of data for fall risk assessment. It can be performed in a very limited space and needs only minimal additional equipment, yet provides large amounts of information, as the presented system can obtain much more data than traditional observation by capturing minute details regarding body movement. The readings are provided wirelessly by one to seven low-cost micro-electro-mechanical inertial measurement units attached to the subject's body segments. Combined with a body model, these allow segment rotations and translations to be computed and for body movements to be recreated in software. The subject can then be automatically classified by an artificial neural network based on selected values in the test, and those with an elevated risk of falls can be identified. Results obtained from a group of 40 subjects of various ages, both healthy volunteers and patients with vestibular system impairment, are presented to demonstrate the combined capabilities of the test and system. Labelling of subjects as fallers and non-fallers was performed using an objective and precise sensory organization test; it is an important novelty as this approach to subject labelling has never before been used in the design and evaluation of fall risk assessment systems. The findings show a true-positive ratio of 85% and true-negative ratio of 63% for classifying subjects as fallers or non-fallers using the introduced fast mobility test, which are noticeably better than those obtained for the long-established Timed Up and Go test.
Finding NEMO in preeclampsia Sakowicz, Agata, PhD; Hejduk, Paulina, PhD; Pietrucha, Tadeusz, PhD ...
American journal of obstetrics and gynecology,
04/2016, Letnik:
214, Številka:
4
Journal Article
Recenzirano
Background The mechanism of preeclampsia and its way of inheritance are still a mystery. Biochemical and immunochemical studies reveal a substantial increase in tumor necrosis factor alpha, ...interleukin-1 beta, and interleukin-6 concentrations in the blood of women with preeclampsia. The level of these factors is regulated by nuclear facxtor-kappa B, whose activation in a classical pathway requires inhibitory kappa B kinase gamma (known as NEMO or IKBKG). Moreover, NEMO can schedule between cytoplasma and the nucleus. In the nucleus, IKBKG interacts with other proteins, and thus, it is implicated in the regulation of different gene expressions, which are related to cell cycle progression, proliferation, differentiation, and apoptosis. Objective This is the first study investigating the association between the level of NEMO gene expression and the presence of preeclampsia. We tested the hypothesis that the simultaneous increase in NEMO gene expression both in the mother and her fetus may be responsible for the preeclampsia development. Moreover, the relationships between clinical risk factors of preeclampsia and the levels of NEMO gene expression in blood, umbilical cord blood, and placentas were investigated. Study Design A total of 91 women (43 preeclamptic women and 48 controls) and their children were examined. Real-time reverse transcription–polymerase chain reaction was used to assess the amount total NEMO messenger ribonucleic acid (mRNA) content and the mRNA level of each NEMO transcript from exons 1A, 1B, and 1C in maternal blood, umbilical cord blood, and placentas. Univariate analyses and correlation tests were performed to examine the association between NEMO gene expression and preeclampsia. Results Newborn weight and height, maternal platelet number, and gestational age (week of delivery) were lower in the group of women with preeclampsia than controls. NEMO gene expression level was found to be almost 7 times higher in the group of women with preeclampsia than healthy controls. The correlation analysis found that a simultaneous increase in the expression level of total NEMO mRNA in maternal blood and the mRNA for total NEMO (Rs = 0.311, P < .05), transcripts 1A (Rs = 0.463, P < .01), 1B (Rs = 0.454, P < .01), and 1C (Rs = 0.563, P < .001) in fetal blood was observed in preeclamptic pregnancies. In addition, the mRNA levels for total NEMO and transcripts 1A, 1B, and 1C were lower in placentas derived from pregnancies complicated by preeclampsia. Conclusion Simultaneous increase of NEMO gene expression in maternal and fetal blood seems to be relevant for preeclampsia development. The results of our study also suggest that a decreased NEMO gene expression level in preeclamptic placentas may be the main reason for their intensified apoptosis.
This paper presents a mathematical model for the selection of an optimal power cable conductor cross section and the dimensions of a corrective backfill. To this end, a detailed model for the ...calculation of the life-cycle cost of cable ownership is presented. The formula considers the material and labor costs in the production of a power cable as well as the cost of losses during its operation. Simultaneously, the procedure seeks the optimal size of the corrective backfill, taking ampacity constraints into account. Since the formulation is complex, a genetic algorithm is proposed to solve the optimization problem. A real-life numerical example is presented.
Atmospheric pressure is the most objective weather factor because regardless of if outdoors or indoors it affects all objects in the same way. The majority of previous studies have used the average ...daily values of atmospheric pressure in a bioclimatic analysis and have found no correlation with blood pressure changes. The main objective of our research was to assess the relationship between atmospheric pressure recorded with a frequency of 1 measurement per minute and the results of 24-h blood pressure monitoring in patients with treated hypertension in different seasons in the moderate climate of the City of Łódź (Poland).
The study group consisted of 1662 patients, divided into 2 equal groups (due to a lower and higher average value of atmospheric pressure). Comparisons between blood pressure values in the 2 groups were performed using the Mann-Whitney U test.
We observed a significant difference in blood pressure recorded during the lower and higher range of atmospheric pressure: on the days of the spring months systolic (p = 0.043) and diastolic (p = 0.005) blood pressure, and at nights of the winter months systolic blood pressure (p = 0.013).
A significant inverse relationship between atmospheric pressure and blood pressure during the spring days and, only for systolic blood pressure, during winter nights was observed. Int J Occup Med Environ Health 2016;29(5):783-792.
•The linear model for the optimal cable conductor size proposed by the IEC is correct.•Selection of optimal cable conductor size requires detailed cable cost information.•Optimization procedure can ...be used to obtain an optimal power cable conductor size.•The cost of losses can be equal to the cost of the cable; hence they cannot be ignored.
The purpose of this paper is to validate the model for the selection of the optimal power cable conductor cross section presented in the IEC Standard 60287-3-2. To this end, a detailed model for the calculation of the life-cycle cost of cable ownership is presented. The formula takes into account both the material and labor costs in the production of a power cable as well as the cost of losses during its operation. Since the formula is fairly complex, a genetic algorithm is proposed to solve the optimization problem. A real-life numerical example is presented.