► Addition order of test media and Ag-NP influences the repeatability of assays. ► Nitrosomonas europaea is most sensitive to Ag+, followed by 20nm Ag-NP then 80nm Ag-NP. ► Dissolved Ag (dAg) was ...found to be responsible for Ag-NP toxicity. ► dAg release was inversely proportional to the surface area to volume ratio. ► Aggregation of Ag-NP resulted in decreased dAg release and decreased toxicity.
The ecotoxicity of silver nanoparticles (Ag-NPs) to wastewater biota, including ammonia oxidizing bacteria (AOB), is gaining increasing interest as the number of products containing Ag-NPs continues to rise exponentially and they are expected to accumulate in wastewater treatment plants. This research demonstrated that the addition order of Ag-NP and the media constituents had a profound influence on the stability of the Ag-NP suspension and the corresponding repeatability of results and sensitivity of Nitrosomonas europaea. N. europaea, a model AOB, was found to be extremely sensitive to ionic silver (Ag+) and two sizes of Ag-NPs (20 and 80nm). Ag+ exposures resulted in the highest level of toxicity with smaller Ag-NPs (20nm) being more toxic than larger Ag-NPs (80nm). The increased sensitivity of N. europaea to smaller Ag-NPs was caused by their higher rates of dissolved silver (dAg) release, via dissolution, due to a greater surface area to volume ratio. dAg was shown to be responsible for the vast majority of the observed Ag-NP toxicity, as determined by abiotic Ag-NP dissolution tests. For the sizes of Ag-NP studied (20 and 80nm), there appears to be a negligible nanoparticle-specific toxicity. This was further supported by similarities in inhibition mechanisms between Ag+ and Ag-NP, with both causing decreases in AMO activity and destabilization of the outer-membrane of N. europaea. Finally, equal concentrations of total silver were found to be tightly associated to both Ag+ and Ag-NP-exposed cells despite Ag-NP concentrations being five times greater, by mass, than Ag+ concentrations.
Here, several methods of generating three constituent quarks in a nucleon are evaluated which explicitly maintain the nucleon's center of mass and desired radial distribution and can be used within ...Monte Carlo Glauber frameworks. The geometric models provided by each method are used to generate distributions over the number of constituent quark participants (Nqp) in p+p,d+Au, and Au+Au collisions. The results are compared with each other and to a previous result of Nqp calculations, without this explicit constraint, used in measurements of √SNN = 200 GeV p+p,d+Au, and Au+Au collisions at the BNL Relativistic Heavy Ion Collider.
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider will perform high-precision measurements of jets and heavy flavor observables for a ...wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with the plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is <inline-formula> <tex-math notation="LaTeX">2.8\%\oplus 15.5\%/\sqrt {E} </tex-math></inline-formula> and the energy resolution for hadrons in the combined EMCal plus HCal system is <inline-formula> <tex-math notation="LaTeX">13.5\%\oplus 64.9\%/\sqrt {E} </tex-math></inline-formula>. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.
The adsorption of natural organic matter (NOM) to the surfaces of natural colloids and engineered nanoparticles is known to strongly influence, and in some cases control, their surface properties and ...aggregation behavior. As a result, the understanding of nanoparticle fate, transport, and toxicity in natural systems must include a fundamental framework for predicting such behavior. Using a suite of gold nanoparticles (AuNPs) with different capping agents, the impact of surface functionality, presence of natural organic matter, and aqueous chemical composition (pH, ionic strength, and background electrolytes) on the surface charge and colloidal stability of each AuNP type was investigated. Capping agents used in this study were as follows: anionic (citrate and tannic acid), neutral (2,2,2-mercaptoethoxy(ethoxy)ethanol and polyvinylpyrrolidone), and cationic (mercaptopentyl(trimethylammonium)). Each AuNP type appeared to adsorb Suwannee River Humic Acid (SRHA) as evidenced by measurable decreases in zeta potential in the presence of 5 mg C L−1 SRHA. It was found that 5 mg C L−1 SRHA provided a stabilizing effect at low ionic strength and in the presence of only monovalent ions while elevated concentrations of divalent cations lead to enhanced aggregation. The colloidal stability of the NPs in the absence of NOM is a function of capping agent, pH, ionic strength, and electrolyte valence. In the presence of NOM at the conditions examined in this study, the capping agent is a less important determinant of stability, and the adsorption of NOM is a controlling factor.
A reaction plane detector for PHENIX at RHIC Richardson, E.; Akiba, Y.; Anderson, N. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2011, Letnik:
636, Številka:
1
Journal Article
Recenzirano
Odprti dostop
A plastic scintillator paddle detector with embedded fiber light guides and photomultiplier tube readout, referred to as the Reaction Plane Detector (RXNP), was designed and installed in the PHENIX ...experiment prior to the 2007 run of the Relativistic Heavy Ion Collider (RHIC). The RXNP's design is optimized to accurately measure the reaction plane (RP) angle of heavy-ion collisions, where, for mid-central sNN=200GeV Au+Au collisions, it achieved a 2nd harmonic RP resolution of ∼0.75, which is a factor of ∼2 greater than PHENIX's previous capabilities. This improvement was accomplished by locating the RXNP in the central region of the PHENIX experiment, where, due to its large coverage in pseudorapidity (1.0<|η|<2.8) and ϕ(2π), it is exposed to the high particle multiplicities needed for an accurate RP measurement. To enhance the observed signal, a 2-cm Pb converter is located between the nominal collision region and the scintillator paddles, allowing neutral particles produced in the heavy-ion collisions to contribute to the signal through conversion electrons. This paper discusses the design, operation and performance of the RXNP during the 2007 RHIC run.
We report a measurement of the angular distributions of Drell-Yan dimuons produced using an 800 GeV/c proton beam on a deuterium target. The muon angular distributions in the dilepton rest frame have ...been measured over the kinematic range 4.5<m{mu mu}<15 GeV/c{2}, 0<p{T}<4 GeV/c, and 0<x{F}<0.8. No significant cos2phi dependence is found in these proton-induced Drell-Yan data, in contrast with the situation for pion-induced Drell-Yan data. The data are compared with expectations from models which attribute the cos2phi distribution to a QCD vacuum effect or to the presence of the transverse-momentum-dependent Boer-Mulders structure function h{1}{perpendicular}. Constraints on the magnitude of the sea-quark h{1}{perpendicular} structure functions are obtained.
We report a high statistics measurement of Upsilon production with an 800 GeV/c proton beam on hydrogen and deuterium targets. The dominance of the gluon-gluon fusion process for Upsilon production ...at this energy implies that the cross section ratio, sigma(p+d-->Upsilon)/2sigma(p+p-->Upsilon), is sensitive to the gluon content in the neutron relative to that in the proton. Over the kinematic region 0<x(F)<0.6, this ratio is found to be consistent with unity, in striking contrast to the behavior of the Drell-Yan cross section ratio sigma(p+d)(DY)/2sigma(p+p)(DY). This result shows that the gluon distributions in the proton and neutron are very similar. The Upsilon production cross sections are also compared with the p+d and p+Cu cross sections from earlier measurements.
The PHENIX Electromagnetic Calorimeter (EMCal) is used to measure the spatial position and energy of electrons and photons produced in heavy ion collisions. It covers the full central spectrometer ...acceptance of 70°⩽
θ⩽110° with two walls, each subtending 90° in azimuth. One wall comprises four sectors of a Pb-scintillator sampling calorimeter and the other has two sectors of Pb-scintillator and two of a Pb-glass Cherenkov calorimeter. Both detectors have very good energy, spatial and timing resolution, while the Pb-scintillator excels in timing and the Pb-glass in energy measurements. Also, having two detectors with different systematics increases the confidence level of the physics results. Design and operational parameters of the Pb-scintillator, Pb-glass and special readout electronics for EMCal are presented and running experience during the first year of data taking with PHENIX is discussed. Some examples of data taken during the first run are shown.