SABRE aims to directly measure the annual modulation of the dark matter interaction rate with NaI(Tl) crystals. A modulation compatible with the standard hypothesis, in which our Galaxy is immersed ...in a dark matter halo, has been measured by the DAMA experiment in the same target material. Other direct detection experiments, using different target materials, seem to exclude the interpretation of such modulation in the simplest scenario of WIMP-nucleon elastic scattering. The SABRE experiment aims to carry out an independent search with sufficient sensitivity to confirm or refute the DAMA claim. The goal of the SABRE experiment is to achieve the lowest background rate for a NaI(Tl) experiment (order of 0.1 cpd/kg/keV
ee
in the energy region of interest for dark matter). This challenging goal could be achievable by operating high-purity crystals inside a liquid scintillator veto for active background rejection. In addition, twin detectors will be located in the northern and southern hemispheres to identify possible contributions to the modulation from seasonal or site-related effects. The SABRE project includes an initial Proof-of-Principle phase at LNGS (Italy), to assess the radio-purity of the crystals and the efficiency of the liquid scintillator veto. This paper describes the general concept of SABRE and the expected sensitivity to WIMP annual modulation.
We present here a characterization of the low background NaI(Tl) crystal NaI-33 based on a period of almost one year of data taking (891 kg
×
days exposure) in a detector configuration with no use of ...organic scintillator veto. This remarkably radio-pure crystal already showed a low background in the SABRE Proof-of-Principle (PoP) detector, in the low energy region of interest (1–6 keV) for the search of dark matter interaction via the annual modulation signature. As the vetoable background components, such as
40
K, are here sub-dominant, we reassembled the PoP setup with a fully passive shielding. We upgraded the selection of events based on a Boosted Decision Tree algorithm that rejects most of the PMT-induced noise while retaining scintillation signals with > 90% efficiency in 1–6 keV. We find an average background of 1.39 ± 0.02 counts/day/kg/keV in the region of interest and a spectrum consistent with data previously acquired in the PoP setup, where the external veto background suppression was in place. Our background model indicates that the dominant background component is due to decays of
210
Pb, only partly residing in the crystal itself. The other location of
210
Pb is the reflector foil that wraps the crystal. We now proceed to design the experimental setup for the physics phase of the SABRE North detector, based on an array of similar crystals, using a low radioactivity PTFE reflector and further improving the passive shielding strategy, in compliance with the new safety and environmental requirements of Laboratori Nazionali del Gran Sasso.
A revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 ...Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.
We present new results on the radiopurity of a 3.4-kg NaI(Tl) crystal scintillator operated in the SABRE proof-of-principle detector setup. The amount of potassium contamination, determined by the ...direct counting of radioactive 40K, is found to be 2.2 ± 1.5 ppb , lowest ever achieved for NaI(Tl) crystals. With the active veto, the average background rate in the crystal in the 1–6 keV energy region of interest (ROI) is 1.20 ± 0.05 counts / day / kg / keV , which is a breakthrough since the DAMA/LIBRA experiment. Our background model indicates that the rate is dominated by 210Pb and that about half of this contamination is located in the polytetrafluoroethylene reflector. We discuss ongoing developments of the crystal manufacture aimed at the further reduction of the background, including data from purification by zone refining. A projected background rate lower than ∼ 0.2 counts / day / kg / keV in the ROI is within reach. These results represent a benchmark for the development of next-generation NaI(Tl) detector arrays for the direct detection of dark matter particles.
Ultra-pure NaI(Tl) crystals are the key element for a model-independent verification of the long standing DAMA result and a powerful means to search for the annual modulation signature of dark matter ...interactions. The SABRE collaboration has been developing cutting-edge techniques for the reduction of intrinsic backgrounds over several years. In this paper we report the first characterization of a 3.4 kg crystal, named NaI-33, performed in an underground passive shielding setup at LNGS. NaI-33 has a record low
39
K contamination of 4.3 ± 0.2 ppb as determined by mass spectrometry. We measured a light yield of 11.1 ± 0.2 photoelectrons/keV and an energy resolution of 13.2% (FWHM/E) at 59.5 keV. We evaluated the activities of
226
Ra and
228
Th inside the crystal to be
5.9
±
0.6
μ
Bq/kg and
1.6
±
0.3
μ
Bq/kg, respectively, which would indicate a contamination from
238
U and
232
Th at part-per-trillion level. We measured an activity of 0.51 ± 0.02 mBq/kg due to
210
Pb out of equilibrium and a
α
quenching factor of 0.63 ± 0.01 at 5304 keV. We illustrate the analyses techniques developed to reject electronic noise in the lower part of the energy spectrum. A cut-based strategy and a multivariate approach indicated a rate, attributed to the intrinsic radioactivity of the crystal, of
∼
1 count/day/kg/keV in the 5–20 keV region.
The energy deposition spectra of 37Ar and 71Ge in a miniature proportional counter are measured and compared in detail to the model response simulated with Geant4. A certain modification of the ...Geant4 code, making it possible to trace the deexcitation of atomic shells properly, is suggested. Modified Geant4 is able to reproduce a response of particle detectors in detail in the keV energy range. This feature is very important for the laboratory experiments that search for massive sterile neutrinos as well as for dark matter searches that employ direct detection of recoil nuclei. This work demonstrates the reliability of Geant4 simulation at low energies.