An experiment with a newly developed high-resolution kaon spectrometer and a scattered electron spectrometer with a novel configuration was performed in Hall C at Jefferson Lab. The ground state of a ...neutron-rich hypernucleus, HeΛ⁷, was observed for the first time with the (e, e'K⁺) reaction with an energy resolution of ~0.6 MeV. This resolution is the best reported to date for hypernuclear reaction spectroscopy. The HeΛ⁷ binding energy supplies the last missing information of the A=7, T=1 hypernuclear isotriplet, providing a new input for the charge symmetry breaking effect of the ΛN potential.
DAQ system for LEPS experiment Sugaya, Y.; Ahn, J.K.; Akimune, H. ...
IEEE transactions on nuclear science,
08/2001, Letnik:
48, Številka:
4
Journal Article
Recenzirano
A data acquisition (DAQ) system for experiments with the Laser Electron Photons at SPring-8 (LEPS) has been developed based on network distributed architecture. The system is designed so as to ...transfer digitized data with a 1-kHz trigger rate from various front-end electronics. Four local DAQ systems with VME board computers at the front end play a role to provide modularity, scalability, and flexibility. Data from each local DAQ system are sent through fast Ethernet to the data server. With this DAQ system, experiments to measure /spl phi/ photoproduction at LEPS started on May 2000. Signals from scintillation counters, drift chambers, and silicon strip detectors were successfully stored on disk. The performance of the present DAQ system is found to be good enough for the measurement.