Imaging Atherosclerosis Tarkin, Jason M; Dweck, Marc R; Evans, Nicholas R ...
Circulation research,
2016-Feb-19, Letnik:
118, Številka:
4
Journal Article
Recenzirano
Odprti dostop
Advances in atherosclerosis imaging technology and research have provided a range of diagnostic tools to characterize high-risk plaque in vivo; however, these important vascular imaging methods ...additionally promise great scientific and translational applications beyond this quest. When combined with conventional anatomic- and hemodynamic-based assessments of disease severity, cross-sectional multimodal imaging incorporating molecular probes and other novel noninvasive techniques can add detailed interrogation of plaque composition, activity, and overall disease burden. In the catheterization laboratory, intravascular imaging provides unparalleled access to the world beneath the plaque surface, allowing tissue characterization and measurement of cap thickness with micrometer spatial resolution. Atherosclerosis imaging captures key data that reveal snapshots into underlying biology, which can test our understanding of fundamental research questions and shape our approach toward patient management. Imaging can also be used to quantify response to therapeutic interventions and ultimately help predict cardiovascular risk. Although there are undeniable barriers to clinical translation, many of these hold-ups might soon be surpassed by rapidly evolving innovations to improve image acquisition, coregistration, motion correction, and reduce radiation exposure. This article provides a comprehensive review of current and experimental atherosclerosis imaging methods and their uses in research and potential for translation to the clinic.
Objective
To systematically investigate the literature for the influence of sublingual nitroglycerin administration on coronary diameter, the number of evaluable segments, image quality, heart rate ...and blood pressure, and diagnostic accuracy of coronary computed tomography (CT) angiography.
Methods
A systematic search was performed in PubMed, EMBASE and Web of Science. The studies were evaluated for the effect of sublingual nitroglycerin on coronary artery diameter, evaluable segments, objective and subjective image quality, systemic physiological effects and diagnostic accuracy. Due to the heterogeneous reporting of outcome measures, a narrative synthesis was applied.
Results
Of the 217 studies identified, nine met the inclusion criteria: seven reported on the effect of nitroglycerin on coronary artery diameter, six on evaluable segments, four on image quality, five on systemic physiological effects and two on diagnostic accuracy. Sublingual nitroglycerin administration resulted in an improved evaluation of more coronary segments, in particular, in smaller coronary branches, better image quality and improved diagnostic accuracy. Side effects were mild and were alleviated without medical intervention.
Conclusion
Sublingual nitroglycerin improves the coronary diameter, the number of assessable segments, image quality and diagnostic accuracy of coronary CT angiography without major side effects or systemic physiological changes.
Key Points
•
Sublingual nitroglycerin administration results in significant coronary artery dilatation
.
•
Nitroglycerin increases the number of evaluable coronary branches
.
•
Image quality is improved the most in smaller coronary branches
.
•
Nitroglycerin increases the diagnostic accuracy of coronary CT angiography
.
•
Most side effects are mild and do not require medical intervention
.
To determine the agreement and reliability of fully automated coronary artery calcium (CAC) scoring in a lung cancer screening population.
1793 low-dose chest CT scans were analyzed ...(non-contrast-enhanced, non-gated). To establish the reference standard for CAC, first automated calcium scoring was performed using a preliminary version of a method employing coronary calcium atlas and machine learning approach. Thereafter, each scan was inspected by one of four trained raters. When needed, the raters corrected initially automaticity-identified results. In addition, an independent observer subsequently inspected manually corrected results and discarded scans with gross segmentation errors. Subsequently, fully automatic coronary calcium scoring was performed. Agatston score, CAC volume and number of calcifications were computed. Agreement was determined by calculating proportion of agreement and examining Bland-Altman plots. Reliability was determined by calculating linearly weighted kappa (κ) for Agatston strata and intraclass correlation coefficient (ICC) for continuous values.
44 (2.5%) scans were excluded due to metal artifacts or gross segmentation errors. In the remaining 1749 scans, median Agatston score was 39.6 (P25-P75∶0-345.9), median volume score was 60.4 mm3 (P25-P75∶0-361.4) and median number of calcifications was 2 (P25-P75∶0-4) for the automated scores. The κ demonstrated very good reliability (0.85) for Agatston risk categories between the automated and reference scores. The Bland-Altman plots showed underestimation of calcium score values by automated quantification. Median difference was 2.5 (p25-p75∶0.0-53.2) for Agatston score, 7.6 (p25-p75∶0.0-94.4) for CAC volume and 1 (p25-p75∶0-5) for number of calcifications. The ICC was very good for Agatston score (0.90), very good for calcium volume (0.88) and good for number of calcifications (0.64).
Fully automated coronary calcium scoring in a lung cancer screening setting is feasible with acceptable reliability and agreement despite an underestimation of the amount of calcium when compared to reference scores.
Coronary artery calcium (CAC) is a strong and independent predictor of cardiovascular disease (CVD) risk. This study assesses reproducibility of automatic CAC scoring on radiotherapy planning ...computed tomography (CT) scans of breast cancer patients, and examines its association with traditional cardiovascular risk factors.
This study included 561 breast cancer patients undergoing radiotherapy between 2013 and 2015. CAC was automatically scored with an algorithm using supervised pattern recognition, expressed as Agatston scores and categorized into five categories (0, 1-10, 11-100, 101-400, >400). Reproducibility between automatic and manual expert scoring was assessed in 79 patients with automatically determined CAC above zero and 84 randomly selected patients without automatically determined CAC. Interscan reproducibility of automatic scoring was assessed in 294 patients having received two scans (82% on the same day). Association between CAC and CVD risk factors was assessed in 36 patients with CAC scores >100, 72 randomly selected patients with scores 1-100, and 72 randomly selected patients without CAC. Reliability was assessed with linearly weighted kappa and agreement with proportional agreement.
134 out of 561 (24%) patients had a CAC score above zero. Reliability of CVD risk categorization between automatic and manual scoring was 0.80 (95% Confidence Interval (CI): 0.74-0.87), and slightly higher for scans with breath-hold. Agreement was 0.79 (95% CI: 0.72-0.85). Interscan reliability was 0.61 (95% CI: 0.50-0.72) with an agreement of 0.84 (95% CI: 0.80-0.89). Ten out of 36 (27.8%) patients with CAC scores above 100 did not have other cardiovascular risk factors.
Automatic CAC scoring on radiotherapy planning CT scans is a reliable method to assess CVD risk based on Agatston scores. One in four breast cancer patients planned for radiotherapy have elevated CAC score. One in three patients with high CAC scores don't have other CVD risk factors and wouldn't have been identified as high risk.
Objective
To determine inter-observer and inter-examination variability of manual attenuation measurements of the vertebrae in low-dose unenhanced chest computed tomography (CT).
Methods
Three ...hundred and sixty-seven lung cancer screening trial participants who underwent baseline and repeat unenhanced low-dose CT after 3 months because of an indeterminate lung nodule were included. The CT attenuation value of the first lumbar vertebrae (L1) was measured in all CTs by one observer to obtain inter-examination reliability. Six observers performed measurements in 100 randomly selected CTs to determine agreement with limits of agreement and Bland-Altman plots and reliability with intraclass correlation coefficients (ICCs). Reclassification analyses were performed using a threshold of 110 HU to define osteoporosis.
Results
Inter-examination reliability was excellent with an ICC of 0.92 (
p
< 0.001). Inter-examination limits of agreement ranged from -26 to 28 HU with a mean difference of 1 ± 14 HU. Inter-observer reliability ICCs ranged from 0.70 to 0.91. Inter-examination variability led to 11.2 % reclassification of participants and inter-observer variability led to 22.1 % reclassification.
Conclusions
Vertebral attenuation values can be manually quantified with good to excellent inter-examination and inter-observer reliability on unenhanced low-dose chest CT. This information is valuable for early detection of osteoporosis on low-dose chest CT.
Key Points
•
Vertebral attenuation values can be manually quantified on low-dose unenhanced CT reliably.
•
Vertebral attenuation measurements may be helpful in detecting subclinical low bone density.
•
This could become of importance in the detection of osteoporosis.
Background: Predictors of recurrent ischemic stroke are less well known in patients with a recent ischemic stroke than in patients with transient ischemic attack (TIA). We identified clinical and ...radiological factors for predicting recurrent ischemic stroke in patients with recent ischemic stroke. Methods: A systematic search in PubMed, Embase, Cochrane Library, and CINAHL was performed with the terms “ischemic stroke,” “predictors/determinants,” and “recurrence.” Quality assessment of the articles was performed and the level of evidence was graded for the articles included for the meta-analysis. Pooled risk ratios (RR) and heterogeneity (I 2 ) were calculated using inverse variance random effects models. Results: Ten articles with high-quality results were identified for meta-analysis. Past medical history of stroke or TIA was a predictor of recurrent ischemic stroke (pooled RR 2.5, 95% CI 2.1–3.1). Small vessel strokes were associated with a lower risk of recurrence than large vessel strokes (pooled RR 0.3, 95% CI 0.1–0.7). Patients with stroke of an undetermined cause had a lower risk of recurrence than patients with large artery atherosclerosis (pooled RR 0.5, 95% CI 0.2–1.1). We found no studies using CT or ultrasound for the prediction of recurrent ischemic stroke. The following MRI findings were predictors of recurrent ischemic stroke: multiple lesions (pooled RR 1.7, 95% CI 1.5–2.0), multiple stage lesions (pooled RR 4.1, 95% CI 3.1–5.5), multiple territory lesions (pooled RR 2.9, 95% CI 2.0–4.2), chronic infarcts (pooled RR 1.5, 95% CI 1.2–1.9), and isolated cortical lesions (pooled RR 2.2, 95% CI 1.5–3.2). Conclusions: In patients with a recent ischemic stroke, a history of stroke or TIA and the subtype large artery atherosclerosis are associated with an increased risk of recurrent ischemic stroke. Predictors evaluated with MRI include multiple ischemic changes and isolated cortical lesions. Predictors of recurrent ischemic stroke concerning CT or ultrasound have not been published.
Objectives
To compare image noise, image quality and diagnostic accuracy of coronary CT angiography (cCTA) using a novel iterative reconstruction algorithm versus traditional filtered back projection ...(FBP) and to estimate the potential for radiation dose savings.
Methods
Sixty five consecutive patients (48 men; 59.3 ± 7.7 years) prospectively underwent cCTA and coronary catheter angiography (CCA). Full radiation dose data, using all projections, were reconstructed with FBP. To simulate image acquisition at half the radiation dose, 50% of the projections were discarded from the raw data. The resulting half-dose data were reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE). Full-dose FBP and half-dose iterative reconstructions were compared with regard to image noise and image quality, and their respective accuracy for stenosis detection was compared against CCA.
Results
Compared with full-dose FBP, half-dose iterative reconstructions showed significantly (
p
= 0.001 –
p
= 0.025) lower image noise and slightly higher image quality. Iterative reconstruction improved the accuracy of stenosis detection compared with FBP (per-patient: accuracy 96.9% vs. 93.8%, sensitivity 100% vs. 100%, specificity 94.6% vs. 89.2%, NPV 100% vs. 100%, PPV 93.3% vs. 87.5%).
Conclusions
Iterative reconstruction significantly reduces image noise without loss of diagnostic information and holds the potential for substantial radiation dose reduction from cCTA.
In this study, we propose a fast and accurate method to automatically localize anatomical landmarks in medical images. We employ a global-to-local localization approach using fully convolutional ...neural networks (FCNNs). First, a global FCNN localizes multiple landmarks through the analysis of image patches, performing regression and classification simultaneously. In regression, displacement vectors pointing from the center of image patches towards landmark locations are determined. In classification, presence of landmarks of interest in the patch is established. Global landmark locations are obtained by averaging the predicted displacement vectors, where the contribution of each displacement vector is weighted by the posterior classification probability of the patch that it is pointing from. Subsequently, for each landmark localized with global localization, local analysis is performed. Specialized FCNNs refine the global landmark locations by analyzing local sub-images in a similar manner, i.e. by performing regression and classification simultaneously and combining the results. Evaluation was performed through localization of 8 anatomical landmarks in CCTA scans, 2 landmarks in olfactory MR scans, and 19 landmarks in cephalometric X-rays. We demonstrate that the method performs similarly to a second observer and is able to localize landmarks in a diverse set of medical images, differing in image modality, image dimensionality, and anatomical coverage.
Summary Background Emotional stress is associated with increased risk of cardiovascular disease. We imaged the amygdala, a brain region involved in stress, to determine whether its resting metabolic ...activity predicts risk of subsequent cardiovascular events. Methods Individuals aged 30 years or older without known cardiovascular disease or active cancer disorders, who underwent18 F-fluorodexoyglucose PET/CT at Massachusetts General Hospital (Boston, MA, USA) between Jan 1, 2005, and Dec 31, 2008, were studied longitudinally. Amygdalar activity, bone-marrow activity, and arterial inflammation were assessed with validated methods. In a separate cross-sectional study we analysed the relation between perceived stress, amygdalar activity, arterial inflammation, and C-reactive protein. Image analyses and cardiovascular disease event adjudication were done by mutually blinded researchers. Relations between amygdalar activity and cardiovascular disease events were assessed with Cox models, log-rank tests, and mediation (path) analyses. Findings 293 patients (median age 55 years IQR 45·0–65·5) were included in the longitudinal study, 22 of whom had a cardiovascular disease event during median follow-up of 3·7 years (IQR 2·7–4·8). Amygdalar activity was associated with increased bone-marrow activity ( r =0·47; p<0·0001), arterial inflammation ( r =0·49; p<0·0001), and risk of cardiovascular disease events (standardised hazard ratio 1·59, 95% CI 1·27–1·98; p<0·0001), a finding that remained significant after multivariate adjustments. The association between amygdalar activity and cardiovascular disease events seemed to be mediated by increased bone-marrow activity and arterial inflammation in series. In the separate cross-sectional study of patients who underwent psychometric analysis (n=13), amygdalar activity was significantly associated with arterial inflammation ( r =0·70; p=0·0083). Perceived stress was associated with amygdalar activity ( r =0·56; p=0·0485), arterial inflammation ( r =0·59; p=0·0345), and C-reactive protein ( r =0·83; p=0·0210). Interpretation In this first study to link regional brain activity to subsequent cardiovascular disease, amygdalar activity independently and robustly predicted cardiovascular disease events. Amygdalar activity is involved partly via a path that includes increased bone-marrow activity and arterial inflammation. These findings provide novel insights into the mechanism through which emotional stressors can lead to cardiovascular disease in human beings. Funding None.