To develop preliminary classification criteria for the cryoglobulinaemic syndrome or cryoglobulinaemic vasculitis (CV).
Study part I developed a questionnaire for CV to be included in the formal, ...second part (study part II). Positivity of serum cryoglobulins was defined by experts as an essential condition for CV classification. In study part II, a core set of classification items (questionnaire, clinical and laboratory items, as agreed) was tested in three groups of patients and controls-that is, group A (new patients with the CV), group B (controls with serum cryoglobulins but lacking CV) and group C (controls without serum cryoglobulins but with features which can be observed in CV).
In study part I (188 cases, 284 controls), a positive response to at least two of three selected questions showed a sensitivity of 81.9% and a specificity of 83.5% for CV. This questionnaire was employed and validated in study part II, which included 272 patients in group A and 228 controls in group B. The final classification criteria for CV, by pooling data from group A and group B, required the positivity of questionnaire plus clinical, questionnaire plus laboratory, or clinical plus laboratory items, or all the three, providing a sensitivity of 88.5% and a specificity of 93.6% for CV. By comparing data in group A versus group C (425 controls), the same classification criteria showed a sensitivity 88.5% and a specificity 97.0% for CV.
Classification criteria for CV were developed, and now need validation.
To assess the 6-month effectiveness of the first rituximab (RTX) course in rheumatoid arthritis (RA) and to identify possible predictors of response.
10 European registries submitted anonymised ...datasets (baseline, 3- and 6-month follow-up) from patients with RA who had started RTX, and datasets were pooled and analysed. Heterogeneity between countries was analysed by analysis of variance. Predictors of response were identified by logistic regression.
2019 patients were included (mean age/disease duration 53.8/12.1 years, 80.3% female, 85.6% rheumatoid factor (RF) positive and 76.8% (456/594 patients) anti-cyclic citrullinated peptide antibodies (anti-CCP) positive). For these patients an average of 2.7 disease-modifying antirheumatic drugs (DMARDs) (range 0-10) had failed, and RTX was given as the first biological agent in 36.6% of patients. There was significant heterogeneity between countries for several baseline characteristics, including the number of previous biological agents. Disease Activity Score based on 28 joint counts (DAS28) decreased from 5.8±1.4 at baseline to 4.2±1.4 at 6 months (p<0.0001) and 22.2%/42.5% achieved European League Against Rheumatism (EULAR) good/moderate response. Larger 6-month improvement in DAS28 was observed in RF-positive and anti-CCP-positive versus seronegative patients. The following predictors of EULAR good response at 6 months were identified in a multivariate analysis: anti-CCP positivity (OR=2.86, p=0.003), number of previous DMARDs (OR=0.84, p=0.06), ≤1 previous biological agents (OR=1.89, p=0.04), baseline DAS28 level (OR=0.74, p=0.003).
In this large observational cohort of patients with RA treated with RTX, seropositive patients achieved significantly greater reductions in DAS28 at 6 months than seronegative patients. Effectiveness was best when RTX was used as the first biological agent or after failure of no more than one anti-tumour necrosis factor agent.
Abstract Power electronics is necessary for the independent control of the stator windings of electric aircraft motors. The benefit of using liquid fuel to cool conductors to utilize their high ...current density has enabled power electronics to be cooled by proxy. While small scale semiconductors have been found to be degraded during operation at cryogenic temperatures, results for systems rated for high power cryogenic applications have not been explored as much. In this work we test the performance of IGBT power electronics from room temperature to 77 K, with a focus on temperatures expected for electric aircraft motors using liquid natural gas (LNG, BP about 120 K) as the cooling medium. In this work, the measure of performance was taken to be the ability to be turned on and off (switched) by an input signal provided by a function generator. We also tested the cold-start ability i.e., the lowest temperature in which the power inverter will start. The lowest cold-start temperature was measured as 140 K. Experimentally, we also observed that both conduction losses and switching loss from a low-power constant current with an operational frequency of 10 kHz were sufficient to allow the inverter to work down to 105 K (below the LNG boiling point).
Multifilamentary MgB 2 strands (filament numbers 36 to 114) prepared by the in-situ power-in-tube (PIT) route with carbon doping contents of 0, 2, and 3.2% were wound on barrels for transport J c and ...n -value measurement at 4.2 K in fields of up to 12 T. The strand and gauge lengths were 1 m and 0.5 m. Heat treatments at 675 °C and 650 °C centered around the melting point of Mg (650 °C) and both utilized the liquid-solid reaction. A pair of strands, with and without 2% C doping exhibited the J c (B) crossover effect. Studied were the dependencies of J c on field strength, dopant concentration, and cabling and the dependence of n -value on field strength.