For knee osteoarthritis and related conditions, analysis of biomarkers hold promise to improve early diagnosis and/or offer patient-specific treatment. To compare biomarker analyses, reliable, ...high-quality biopsies are needed. The aim of this work is to summarize the literature on the current best practices of biopsy of the synovium and synovial fluid arthrocentesis. Therefore, PubMed, Embase and Web of Science were systematically searched for articles that applied, demonstrated, or evaluated synovial biopsies or arthrocentesis. Expert recommendations and applications were summarized, and evidence for superiority of techniques was evaluated. Thirty-one studies were identified for inclusion. For arthrocentesis, the superolateral approach in a supine position, with a 0°-30° knee flexion was generally recommended. 18-gage needles, mechanical compression and ultrasound-guidance were found to give superior results. For blind and image-guided synovial biopsy techniques, superolateral and infrapatellar approaches were recommended. Single-handed tools were preconized, including Parker-Pearson needles and forceps. Sample quantity ranged approximately from 2 to 20. Suggestions were compiled for arthrocentesis regarding approach portal and patient position. Further evidence regarding needle size, ultrasound-guidance and mechanical compression were found. More comparative studies are needed before evidence-based protocols can be developed.
Background
Hindfoot malalignment is a recognized cause of foot and ankle disability. For preoperative planning and clinical follow-up, reliable radiographic assessment of hindfoot alignment is ...important. The long axial radiographic view and the hindfoot alignment view are commonly used for this purpose. However, their comparative reliabilities are unknown. As hindfoot varus or valgus malalignment is most pronounced during mid-stance of gait, a unilateral weight-bearing stance, in comparison with a bilateral stance, could increase measurement reliability. The purpose of this study was to compare the intra- and interobserver reliability of hindfoot alignment measurements of both radiographic views in bilateral and unilateral stance.
Materials and methods
A hindfoot alignment view and a long axial view were acquired from 18 healthy volunteers in bilateral and unilateral weight-bearing stances. Hindfoot alignment was defined as the angular deviation between the tibial anatomical axis and the calcaneus longitudinal axis from the radiographs. Repeat measurements of hindfoot alignment were performed by nine orthopaedic examiners.
Results
Measurements from the hindfoot alignment view gave intra- and interclass correlation coefficients (CCs) of 0.72 and 0.58, respectively, for bilateral stance and 0.91 and 0.49, respectively, for unilateral stance. The long axial view showed, respectively, intra- and interclass CCs of 0.93 and 0.79 for bilateral stance and 0.91 and 0.58 for unilateral stance.
Conclusion
The long axial view is more reliable than the hindfoot alignment view or the angular measurement of hindfoot alignment. Although intra-observer reliability is good/excellent for both methods, only the long axial view leads to good interobserver reliability. A unilateral weight-bearing stance does not lead to greater reliability of measurement.
The analysis of samples with large height variations remains a challenge for mass spectrometry imaging (MSI), despite many technological advantages. Ambient sampling and ionization MS techniques ...allow for the molecular analysis of sample surfaces with height variations, but most techniques lack MSI capabilities. We developed a 3D MS scanner for the automated sampling and imaging of a 3D surface with laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS). The sample is moved automatically with a constant distance between the laser probe and sample surface in the 3D MS Scanner. The topography of the surface was scanned with a laser point distance sensor to define the MS measurement points. MS acquisition was performed with LA-REIMS using a surgical CO2 laser coupled to a qTOF instrument. The topographical scan and MS acquisition can be completed within 1 h using the 3D MS scanner for 300 measurement points on uneven samples with a spatial resolution of 2 mm in the top view, corresponding to 22.04 cm2. Comparison between the automated acquisition with the 3D MS scanner and manual acquisition by hand showed that the automation resulted in increased reproducibility between the measurement points. 3D visualizations of molecular distributions related to structural differences were shown for an apple, a marrowbone, and a human femoral head to demonstrate the imaging feasibility of the system. The developed 3D MS scanner allows for the automated sampling of surfaces with uneven topographies with LA-REIMS, which can be used for the 3D visualization of molecular distributions of these surfaces.
In vivo diffuse reflectance spectroscopy provides additional contrast in discriminating nerves embedded in adipose tissue during surgery. However, large datasets are required to achieve clinically ...acceptable classification levels. This study assesses the spectral similarity between ex vivo porcine and in vivo human spectral data of nerve and adipose tissue, as porcine tissue could contribute to generate large datasets.
Porcine diffuse reflectance spectra were measured at 124 nerve and 151 adipose locations. A previously recorded dataset of 32 in vivo human nerve and 23 adipose tissue locations was used for comparison. In total, 36 features were extracted from the raw porcine to generate binary logistic regression models for all combinations of two, three, four and five features. Feature selection was performed by assessing similar means between normalized features of nerve and of adipose tissue (Kruskal-Wallis test,
< 0.05) and for models performing best on the porcine cross validation set. The human test set was used to assess classification performance.
The binary logistic regression models with selected features showed an accuracy of 60% on the test set.
Spectral similarity between ex vivo porcine and in vivo human adipose and nerve tissue was present, but further research is required.
Background
Some commercial simulators are available for training basic arthroscopic skills. However, it is unclear if these simulators allow training for their intended purposes and whether the ...perception of usefulness relates to level of experience.
Questions/purposes
We addressed the following questions: (1) Do commercial simulators have construct (times to perform tasks) and face validity (realism), and (2) is the perception of usefulness (educational value and user-friendliness) related to level of experience?
Methods
We evaluated two commercially available virtual reality simulators (Simulators A and B) and recruited 11 and nine novices (no arthroscopies), four and four intermediates (one to 59 arthroscopies), and seven and nine experts (> 60 arthroscopies) to test the devices. To assess construct validity, we recorded the median time per experience group for each of five repetitions of one identical navigation task. To assess face validity, we used a questionnaire to judge up to three simulator characteristic tasks; the questionnaire asked about the realism, perception of educational value, and perception of user-friendliness.
Results
We observed partial construct validity for Simulators A and B and considered face validity satisfactory for both simulators for simulating the outer appearance and human joint, but barely satisfactory for the instruments. Simulators A and B had equal educational value according to the participants. User-friendliness was judged better for Simulator B although both were graded satisfactory. The perception of usefulness did not differ with level of experience.
Conclusions
Our observations suggest training on either simulator is reasonable preparation for real-life arthroscopy, although there is room for improvement for both simulators.
Clinical Relevance
These simulators provide training in surgical skills without compromising patient safety.
The bones forming the talocrural joint (TCJ) and subtalar joint (STJ) are often assumed to be bilaterally symmetric. Therefore, the contralateral limb (i.e. the fibula, tibia, calcaneus and talus) is ...used as a template or an intra‐subject control in clinical and research practice. However, the validity of the symmetry assumption is controversial, because insufficient information is available on the shape variations and bilateral (a)symmetry of the fibula, tibia, calcaneus and talus. Using three‐dimensional spatially dense sampled representations of bone shapes extracted from bilateral computed tomography scans of 66 individuals (55 male, mean age: 61 ± 10 years; 11 female, mean age: 53 ± 15 years), we analyzed whether: (i) similar shape patterns exist in the left and right bones of the same type; (ii) gender has an effect on bone shape variations; (iii) intra‐subject shape variation is smaller than that of inter‐subject for a given shape variance direction. For the first set of analyses, all left and right instances of the same type of bone were considered as two separate groups, and statistically compared with each other on multiple aspects including group location (central tendency), variance‐covariance scale (dispersion) and orientation (covariance structure) using distance‐based permutational tests. For the second and third sets of analyses, all left and right bones of the same type were pooled into one group, and shape variations in the TCJ and STJ bones were extracted using principal component analysis. The effects of gender on age‐adjusted bone shape differences were assessed using an analysis of covariance. Moreover, intra‐class correlation was employed to evaluate intra‐ and inter‐subject bone shape variations. For each bone type, both sides had similar shape patterns (Ppermutational‐values > 0.05). After Bonferroni adjustment, gender led to shape differences, which were mainly in the lateral and medial condyles of the tibia (P = 0.003), the length and height of the calcaneus (P < 0.001), the posterior and anterior talar articular surfaces of the calcaneus (P = 0.001), and in the posterior aspect of the talus (P = 0.001). Intra‐subject shape variations in the tibial tuberosity together with the diameter of the tibia, and the curvature of the fibula shaft and the diameter of the fibula were as high as those of inter‐subject. This result suggests that the shape symmetry assumption could be violated for some specific shape variations in the fibula and tibia.
Two-dimensional (2-D) plain radiographs may be insufficient for the evaluation of distal radial malunion, as it is a three-dimensional (3-D) deformity. This study introduced a 3-D measuring method ...that outputs radial inclination, ulnar variance, palmar tilt and axial rotation. To this end, a standardized and clearly defined coordinate system was constructed that allowed 3-D measurements closely resembling the conventional 2-D method in 35 patients. Mean differences between 3-D and 2-D measurements in affected wrists were 1.8° for radial inclination, 0.8 mm for ulnar variance and 3.7° for palmar tilt. In addition, inter- and intra-observer reproducibility of all 3-D and 2-D measurements were good or excellent (intraclass correlation coefficient >0.75), with 3-D reproducibility always better than 2-D. Axial rotation was present in all patients with a mean of 7.9° (SD 6.9). Although the differences between 2-D and 3-D measurements were small, 3-D evaluation enables the assessment of axial rotation and brings us closer to a routine 3-D evaluation of malunion.
Level of evidence: III
The incidence of osteoarthritis (OA) has been expected to increase due to an aging population, as well as an increased incidence of intra-articular (osteo-) chondral damage. Lipids have already been ...shown to be involved in the inflammatory process of OA. This study aims at revealing region-specific lipid profiles of the infrapatellar fat pad (IPFP) of OA or cartilage defect patients by matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), which could be used as biomarkers for early OA detection. A higher presence of phospholipids was found in OA patients compared with cartilage defect patients. In addition, a higher abundance of ether-linked phosphatidylethanolamines (PE O-s) containing arachidonic acid was specifically found in OA patients compared with cartilage defect patients. These lipids were mainly found in the connective tissue of the IPFP. Specific lipid species were associated to OA patients compared with cartilage defect patients. PE O-s have been suggested as possible biomarkers for OA. As these were found more abundantly in the connective tissue, the IPFP’s intra-tissue heterogeneity might play an important role in biomarker discovery, implying that the amount of fibrous tissue is associated with OA.
Graphical Abstract
Background:
The objective consisted of 2 elements, primarily to define 2 bone geometry variations of the ankle that may be of prognostic value on ankle instability and secondly to translate these ...bone variations from a 3D model to a simple 2D radiographic measurement for clinical use.
Methods:
The 3D tibial and talar shape differences derived from earlier studies were translated to two 2D radiographic parameters: the medial malleolar height angle (MMHA) and talar convexity angle (TCA) respectively to ensure clinical use. To assess validity, the MMHA and TCA were measured on 3D polygons derived from lower leg computed tomographic (CT) scans and 2D digitally reconstructed radiographs (DRRs) of these polygons. To assess reliability, the MMHA and TCA were measured on standard radiographs by 2 observers calculating the intraclass correlation coefficient (ICC).
Results:
The 3D angle measurements on the polygons showed substantial to excellent agreement with the 2D measurements on DRR for both the MMHA (ICC 0.84-0.93) and TCA (ICC 0.88-0.96). The interobserver reliability was moderate with an ICC of 0.58 and an ICC of 0.64 for both the MMHA and TCA, respectively. The intraobserver reliability was excellent with an ICC of 0.96 and 0.97 for the MMHA and the TCA, respectively.
Conclusion:
Two newly defined radiographic parameters (MMHA and TCA) are valid and can be assessed with excellent intraobserver reliability on standard radiographs. The interobserver reliability was moderate and indicates training is required to ensure uniformity in measurement technique. The current method may be used to translate more variations in bone shape prior to implementation in clinical practice.
Level of Evidence:
Level III, cohort study.
The demand for high quality care is in contrast to reduced training time for residents to develop arthroscopic skills. Thereto, simulators are introduced to train skills away from the operating room. ...In our clinic, a physical simulation environment to Practice Arthroscopic Surgical Skills for Perfect Operative Real-life Treatment (PASSPORT) is being developed. The PASSPORT concept consists of maintaining the normal arthroscopic equipment, replacing the human knee joint by a phantom, and integrating registration devices to provide performance feedback. The first prototype of the knee phantom allows inspection, treatment of menisci, irrigation, and limb stressing. PASSPORT was evaluated for face and construct validity. Construct validity was assessed by measuring the performance of two groups with different levels of arthroscopic experience (20 surgeons and 8 residents). Participants performed a navigation task five times on PASSPORT. Task times were recorded. Face validity was assessed by completion of a short questionnaire on the participants’ impressions and comments for improvements. Construct validity was demonstrated as the surgeons (median task time 19.7 s 8.0–37.6) were more efficient than the residents (55.2 s 27.9–96.6) in task completion for each repetition (Mann–Whitney U test,
P
< 0.05). The prototype of the knee phantom sufficiently imitated limb outer appearance (79%), portal resistance (82%), and arthroscopic view (81%). Improvements are required for the stressing device and the material of cruciate ligaments. Our physical simulation environment (PASSPORT) demonstrates its potential to evolve as a training modality. In future, automated performance feedback is aimed for.