We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses (mχ) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on ...time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg day exposure and 250 eVee threshold for AM analysis. The sensitive windows in mχ are expanded by an order of magnitude to lower DM masses with Migdal effect incorporated. New limits on σχNSI at 90% confidence level are derived as 2×10−32∼7×10−35 cm2 for TI analysis at mχ∼50–180 MeV/c2, and 3×10−32∼9×10−38 cm2 for AM analysis at mχ∼75 MeV/c2–3.0 GeV/c2.
To explore the characteristics of Helicobacter pylori resistance in China and the association between antibiotic resistance and several clinical factors.
H. pylori strains were collected from ...patients in 13 provinces or cities in China between 2010 and 2016. Demographic data including type of disease, geographic area, age, gender and isolation year were collected to analyse their association with antibiotic resistance. Antibiotic resistance was detected using the Etest test and the Kirby-Bauer disc diffusion method.
H. pylori were successfully cultured from 1117 patients. The prevalence of metronidazole, clarithromycin (CLA), azithromycin, levofloxacin (LEV), moxifloxacin, amoxicillin (AMO), tetracycline and rifampicin resistance was 78.2, 22.1, 23.3, 19.2, 17.2, 3.4, 1.9 and 1.5%, respectively. No resistance to furazolidone was observed. The resistance rates to LEV and moxifloxacin were higher in strains isolated from patients with gastritis compared to those with duodenal ulcer and among women. Compared to patients ≥40 years old, younger patients exhibited lower resistance rates to CLA, azithromycin, LEV and moxifloxacin. The resistance rates to CLA and AMO were higher in strains isolated more recently, and we also found that the prevalence of resistance to metronidazole, CLA, azithromycin and AMO were significantly different among different regions of China.
The resistance rates to metronidazole, CLA and LEV were high in China. Patient age, gender, disease and location were associated with the resistance of H. pylori to some antibiotics. Furazolidone, AMO and tetracycline are better choices for H. pylori treatment in China.
ABSTRACT
High time resolution and accuracy are of critical importance in the studies of timing analysis and time delay localization of gamma-ray bursts (GRBs), soft gamma-ray repeaters (SGRs) and ...pulsars. The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) consisting of two micro-satellites, GECAM-A and GECAM-B, launched on 2020 December 10, is aimed at monitoring and locating X-ray and GRBs all over the sky. To achieve its scientific goals, GECAM is designed to have the highest time resolution (0.1 $\mu {\rm s}$) among all GRB detectors ever flown. Here, we make a comprehensive time calibration campaign including both on-ground and on-orbit tests to derive not only the relative time accuracy of GECAM satellites and detectors, but also the absolute time accuracy of GECAM-B. Using the on-ground calibration with a $\rm ^{22}Na$ radioactive source, we find that the relative time accuracy between GECAM-A and GECAM-B is about 0.15 $\mu {\rm s}$ (1σ). To measure the relative time accuracy between all detectors of a single GECAM satellite, cosmic-ray events detected on orbit are utilized since they could produce many secondary particles simultaneously record by multiple detectors. We find that the relative time accuracy among all detectors onboard GECAM-B is about 0.12 $\mu {\rm s}$ (1σ). Finally, we use the novel Li-CCF method to perform the absolute time calibration with Crab pulsar and SGR J1935+2154, both of which were jointly observed by GECAM-B and Fermi/GBM, and obtain that the time difference between GECAM-B and Fermi/GBM is 3.06 ± 6.04 $\mu {\rm s}$ (1σ).
We present improved germanium-based constraints on sub-GeV dark matter via dark matter-electron (χ-e) scattering using the 205.4 kg·day dataset from the CDEX-10 experiment. Using a novel calculation ...technique, we attain predicted χ-e scattering spectra observable in high-purity germanium detectors. In the heavy mediator scenario, our results achieve 3 orders of magnitude of improvement for m_{χ} larger than 80 MeV/c^{2} compared to previous germanium-based χ-e results. We also present the most stringent χ-e cross-section limit to date among experiments using solid-state detectors for m_{χ} larger than 90 MeV/c^{2} with heavy mediators and m_{χ} larger than 100 MeV/c^{2} with electric dipole coupling. The result proves the feasibility and demonstrates the vast potential of a new χ-e detection method with high-purity germanium detectors in ultralow radioactive background.
We report constraints on the dark photon effective kinetic mixing parameter (κ) with data taken from two p-type point-contact germanium detectors of the CDEX-10 experiment at the China Jinping ...Underground Laboratory. The 90% confidence level upper limits on κ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (m_{V}) from 10 to 300 eV/c^{2} in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90% confidence level with m_{V} from 0.1 to 4.0 keV/c^{2} are set from 449.6 kg-day data, with a minimum of κ=1.3×10^{-15} at m_{V}=200 eV/c^{2}.
Here, in an analysis of a 2.92 fb–1 data sample taken at 3.773 GeV with the BESIII detector operated at the BEPCII collider, we measure the absolute decay branching fractions to be B(D0 → K–e+νe) = ...(3.505 ± 0.014 ± 0.033)% and B(D0 → π–e+νe) = (0.295 ± 0.004 ± 0.003)%. From a study of the differential decay rates we obtain the products of hadronic form factor and the magnitude of the CKM matrix element $f$ $^{K}_{+}$(0)|Vcs| = 0.7172 ± 0.0025 ± 0.0035 and $f$ $^{π}_{+}$(0)|Vcd| = 0.1435 ± 0.0018 ± 0.0009.