The measurement of the energy spectrum of cosmic ray helium nuclei from 70 GeV to 80 TeV using 4.5 years of data recorded by the Dark Matter Particle Explorer (DAMPE) is reported in this work. A ...hardening of the spectrum is observed at an energy of about 1.3 TeV, similar to previous observations. In addition, a spectral softening at about 34 TeV is revealed for the first time with large statistics and well controlled systematic uncertainties, with an overall significance of 4.3σ. The DAMPE spectral measurements of both cosmic protons and helium nuclei suggest a particle charge dependent softening energy, although with current uncertainties a dependence on the number of nucleons cannot be ruled out.
With the aim of gathering temporal trends on bacterial epidemiology and resistance from multiple laboratories in China, the CHINET surveillance system was organized in 2005. Antimicrobial ...susceptibility testing was carried out according to a unified protocol using the Kirby-Bauer method or automated systems. Results were analyzed according to Clinical and Laboratory Standards Institute (CLSI) 2014 definitions. Between 2005 and 2014, the number of bacterial isolates ranged between 22 774 and 84 572 annually. Rates of extended-spectrum β-lactamase production among Escherichia coli isolates were stable, between 51.7 and 55.8%. Resistance of E. coli and Klebsiella pneumoniae to amikacin, ciprofloxacin, piperacillin/tazobactam and cefoperazone/sulbactam decreased with time. Carbapenem resistance among K. pneumoniae isolates increased from 2.4 to 13.4%. Resistance of Pseudomonas aeruginosa strains against all of antimicrobial agents tested including imipenem and meropenem decreased with time. On the contrary, resistance of Acinetobacter baumannii strains to carbapenems increased from 31 to 66.7%. A marked decrease of methicillin resistance from 69% in 2005 to 44.6% in 2014 was observed for Staphylococcus aureus. Carbapenem resistance rates in K. pneumoniae and A. baumannii in China are high. Our results indicate the importance of bacterial surveillance studies.
To explore the characteristics of Helicobacter pylori resistance in China and the association between antibiotic resistance and several clinical factors.
H. pylori strains were collected from ...patients in 13 provinces or cities in China between 2010 and 2016. Demographic data including type of disease, geographic area, age, gender and isolation year were collected to analyse their association with antibiotic resistance. Antibiotic resistance was detected using the Etest test and the Kirby-Bauer disc diffusion method.
H. pylori were successfully cultured from 1117 patients. The prevalence of metronidazole, clarithromycin (CLA), azithromycin, levofloxacin (LEV), moxifloxacin, amoxicillin (AMO), tetracycline and rifampicin resistance was 78.2, 22.1, 23.3, 19.2, 17.2, 3.4, 1.9 and 1.5%, respectively. No resistance to furazolidone was observed. The resistance rates to LEV and moxifloxacin were higher in strains isolated from patients with gastritis compared to those with duodenal ulcer and among women. Compared to patients ≥40 years old, younger patients exhibited lower resistance rates to CLA, azithromycin, LEV and moxifloxacin. The resistance rates to CLA and AMO were higher in strains isolated more recently, and we also found that the prevalence of resistance to metronidazole, CLA, azithromycin and AMO were significantly different among different regions of China.
The resistance rates to metronidazole, CLA and LEV were high in China. Patient age, gender, disease and location were associated with the resistance of H. pylori to some antibiotics. Furazolidone, AMO and tetracycline are better choices for H. pylori treatment in China.
We consider the fidelity of the vector meson dominance (VMD) assumption as an instrument for relating the electromagnetic vector-meson production reaction
e
+
p
→
e
′
+
V
+
p
to the purely hadronic ...process
V
+
p
→
V
+
p
. Analyses of the photon vacuum polarisation and the photon-quark vertex reveal that such a VMD
Ansatz
might be reasonable for light vector-mesons. However, when the vector-mesons are described by momentum-dependent bound-state amplitudes, VMD fails for heavy vector-mesons: it cannot be used reliably to estimate either a photon-to-vector-meson transition strength or the momentum dependence of those integrands that would arise in calculations of the different reaction amplitudes. Consequently, for processes involving heavy mesons, the veracity of both cross-section estimates and conclusions based on the VMD assumption should be reviewed, e.g., those relating to hidden-charm pentaquark production and the origin of the proton mass.
By designing a structured gas density profile between the dual-stage gas jets to manipulate electron seeding and energy chirp reversal for compressing the energy spread, we have experimentally ...produced high-brightness high-energy electron beams from a cascaded laser wakefield accelerator with peak energies in the range of 200-600 MeV, 0.4%-1.2% rms energy spread, 10-80 pC charge, and ∼0.2 mrad rms divergence. The maximum six-dimensional brightness B_{6D,n} is estimated as ∼6.5×10^{15} A/m^{2}/0.1%, which is very close to the typical brightness of e beams from state-of-the-art linac drivers. These high-brightness high-energy e beams may lead to the realization of compact monoenergetic gamma-ray and intense coherent x-ray radiation sources.
There are few data on the molecular epidemiology of cryptococcosis in China. Here we investigated the species distribution, molecular types and antifungal susceptibilities of 312 Cryptococcus ...neoformans species complex isolates from ten hospitals over 5 years. Isolates were identified by internal transcribed spacer (ITS) sequencing and by two matrix-assisted laser desorption–ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems. Multilocus sequence typing (MLST) was used to verify species/variety and to designate molecular types. Susceptibility to six antifungal drugs was determined by the Sensititre YeastOne™ method. Cryptococcus neoformans was the predominant species (305/312 isolates (97.8%), all were ITS type 1, serotype A), of which 89.2% (272/305) were C. neoformans var. grubii MLST sequence type (ST) 5 and 6.2% (19/305) were ST31. Other C. neoformans var. grubii STs were rare but included six novel STs. Only two strains were C. neoformans var. neoformans (both serotype AD). Cryptococcus gattii was uncommon (n = 7, four ITS types) and comprised five MLST STs including one novel ST. For C. neoformans var. grubii, the proportion of isolates with non-wild-type MICs to fluconazole significantly rose in the fourth study year (from 0% (0/56 isolates) in the first year to 23.9% (17/71) in the fourth year), including five isolates with fluconazole MICs of ≥32 mg/L. The study has provided useful data on the species epidemiology and their genetic diversity and antifungal susceptibility. The proportional increase in isolates with non-wild-type MICs to fluconazole is noted.
A simple, efficient scheme was developed to obtain near-gigaelectronvolt electron beams with energy spreads of few per-mille level in a single-stage laser wakefield accelerator. Longitudinal plasma ...density was tailored to control relativistic laser-beam evolution, resulting in injection, dechirping, and a quasi-phase-stable acceleration. With this scheme, electron beams with peak energies of 780–840 MeV, rms energy spreads of 2.4‰–4.1‰, charges of 8.5–23.6 pC, and rms divergences of 0.1–0.4 mrad were experimentally obtained. Quasi-three-dimensional particle-in-cell simulations agreed well with the experimental results. The dechirping strength was estimated to reach up to 11 TeV/mm/m, which is higher than previously obtained results. Such high-quality electron beams will boost the development of compact intense coherent radiation sources and x-ray free-electron lasers.
The precise measurement of the spectrum of protons, the most abundant component of the cosmic radiation, is necessary to understand the source and acceleration of cosmic rays in the Milky Way. This ...work reports the measurement of the cosmic ray proton fluxes with kinetic energies from 40 GeV to 100 TeV, with 2
/
years of data recorded by the DArk Matter Particle Explorer (DAMPE). This is the first time that an experiment directly measures the cosmic ray protons up to ~100 TeV with high statistics. The measured spectrum confirms the spectral hardening at ~300 GeV found by previous experiments and reveals a softening at ~13.6 TeV, with the spectral index changing from ~2.60 to ~2.85. Our result suggests the existence of a new spectral feature of cosmic rays at energies lower than the so-called knee and sheds new light on the origin of Galactic cosmic rays.
A symmetry-preserving approach to the two valence-body continuum bound-state problem is used to calculate the elastic electromagnetic form factors of the ρ-meson and subsequently to study the ...evolution of vector-meson form factors with current-quark mass. To facilitate a range of additional comparisons, K* form factors are also computed. The analysis reveals that vector mesons are larger than pseudoscalar mesons; composite vector mesons are nonspherical, with magnetic and quadrupole moments that deviate ∼30% from point-particle values; in many ways, vector-meson properties are as much influenced by emergent mass as those of pseudoscalars; and vector-meson electric form factors possess a zero at spacelike momentum transfer. Qualitative similarities between the electric form factors of the ρ and the proton, GEp, are used to argue that the character of emergent mass in the Standard Model can force a zero in GEp. Moreover, the existence of a zero in vector-meson electric form factors entails that a single-pole vector-meson dominance model can only be of limited use in estimating properties of off-shell vector mesons, providing poor guidance for systems in which the Higgs mechanism of mass generation is dominant.