We present X-ray timing results of the new black hole candidate MAXI J1535−571 during its 2017 outburst from Hard X-ray Modulation Telescope (Insight-HXMT) observations taken from 2017 September 6 to ...23. Following the definitions given by Belloni, we find that the source exhibits transitions from the low/hard state to the hard intermediate state, and eventually to the soft intermediate state. Quasi-periodic oscillations (QPOs) are found in the intermediate states, which suggest different types of QPOs. With the large effective area of Insight-HXMT at high energies, we are able to present the energy dependence of the QPO amplitude and centroid frequency up to 100 keV, which has rarely been explored by previous satellites. We also find that the phase lag at the type-C QPOs centroid frequency is negative (soft lag) and strongly correlated with the centroid frequency. Assuming a geometrical origin of type-C QPOs, the source is consistent with being a high-inclination system.
Members of the genus Aeromonas are opportunistic pathogen of a variety of aquatic animals that exhibits multidrug resistance, phenotypes, virulence genes and virulence. The present study described ...the species distribution and the potential pathogenicity of Aeromonas isolated from healthy Northern snakehead (Channa argus) in China. Molecular identification revealed that A. veronii biovar veronii (69/167; 41·3%) and A. hydrophila (41/167; 24·6%) were the most common species found in Northern snakehead intestine based on sequencing of the 16S rRNA gene and DNA gyrase subunit B protein. The distribution of seven virulence factors including aer (84·4%), act (80·8%), ser (40·1%), Aha (27·5%), lip (23·4%), exu (15·0%) and LuxS (12·6%) were determined exclusively in Aeromonas isolates. All the seven virulence genes were present in 9·6% (16/167), among which 11 strains were identified as A. veronii biovar veronii. For the strains harbouring seven virulence genes, the 50% lethal doses (LD50) of isolates were lower compared to the isolates carrying two virulence genes. The challenge tests revealed that isolate W31 had the lowest lethal dose, causing 50% mortality at 4·5 × 103 colony‐forming units (CFU) per ml. Furthermore, histopathology of Northern snakehead infected with Aeromonas strains showed necrosis and congestion in liver, spleen and kidney and also damage to the intestine. This study confirms that the Aeromonas strains isolated from healthy Northern snakehead may be a cause of concern for public health.
Significance and Impact of the Study
Aeromonas species are widely distributed in aquatic environments and have considerable virulence potential. The aim of this study was to identify Aeromonas strains isolated from healthy Northern snakehead, and to investigate if Aeromonas species isolated from healthy fish potential pathogenicity with special reference to virulence and epidemiology studies.
Significance and Impact of the Study: Aeromonas species are widely distributed in aquatic environments and have considerable virulence potential. The aim of this study was to identify Aeromonas strains isolated from healthy Northern snakehead, and to investigate if Aeromonas species isolated from healthy fish potential pathogenicity with special reference to virulence and epidemiology studies.
The choice of general anaesthetics may affect postoperative cognitive outcomes. This study was designed to compare the potential impact of propofol-based vs sevoflurane-based general anaesthesia on ...the development of delayed neurocognitive recovery in older adults early after major cancer surgery.
Older adults (aged ≥65 and <90 yr) who were scheduled to undergo major cancer surgery (≥2 h) were randomised to receive either propofol- or sevoflurane-based general anaesthesia. Cognitive function was assessed before and 1 week after surgery with a battery of neuropsychological tests. Age- and education-matched non-surgical controls were recruited, and their cognitive functions were tested at comparable time intervals in order to adjust for learning effects from repeated tests. Delayed neurocognitive recovery was diagnosed according to the International Study of Postoperative Cognitive Dysfunction 1 definition.
From April 1, 2015 to October 15, 2016, 392 patients were enrolled and randomised. Of these patients, 387 completed the intervention and 30-day follow-up, and 379 completed 1-week neuropsychological tests. Fifty-nine control subjects were enrolled and completed repeated neuropsychological tests. The incidence of delayed neurocognitive recovery at 1 week was significantly lower in the propofol group 14.8% (28/189) than in the sevoflurane group 23.2% (44/190); odds ratio=0.577; 95% confidence interval, 0.342–0.975; P=0.038. Safety outcomes did not differ between the two groups.
When compared with sevoflurane-based general anaesthesia, propofol-based general anaesthesia might decrease the incidence of delayed neurocognitive recovery in older adults after major cancer surgery.
NCT02662257; Chinese Clinical Trial Registry (identifier: ChiCTR-IPR-15006209).
Context.
Despite over 50 years of research, many open questions remain about the origin and nature of gamma-ray bursts (GRBs). Linear polarization measurements of the prompt emission of these extreme ...phenomena have long been thought to be key to answering a range of these questions. The POLAR detector was designed to produce the first set of detailed and reliable linear polarization measurements in the 50 − 500 keV energy range. During late 2016 and early 2017, POLAR detected a total of 55 GRBs. The analysis results of 5 of these GRBs have been reported, and were found to be consistent with a low or unpolarized flux. However, previous reports by other collaborations found high levels of linear polarization, including some as high as 90%.
Aims.
We study the linear polarization for the 14 GRBs observed by POLAR for which statistically robust inferences are possible. Additionally, time-resolved polarization studies are performed on GRBs with sufficient apparent flux.
Methods.
A publicly available polarization analysis tool, developed within the Multi-Mission Maximum Likelihood framework (
3ML
), was used to produce statistically robust results. The method allows spectral and polarimetric data from POLAR to be combined with spectral data from the
Fermi
Gamma-ray Burst Monitor (
Fermi
-GBM) and the
Neil Gehrels Swift
Observatory to jointly model the spectral and polarimetric parameters.
Results.
The time-integrated analysis finds all results to be compatible with low or zero polarization with the caveat that, when time-resolved analysis is possible within individual pulses, we observe moderate linear polarization with a rapidly changing polarization angle. Therefore, time-integrated polarization results, while pointing to lower polarization, are potentially an artifact of summing over the changing polarization signal and thus washing out the true moderate polarization. We therefore caution against overinterpretation of any time-integrated results inferred herein and encourage the community to wait for more detailed polarization measurements from forthcoming missions such as POLAR-2 and LEAP.
Abstract
Constrained by the Nielsen-Ninomiya no-go theorem, in all so-far experimentally determined Weyl semimetals (WSMs) the Weyl points (WPs) always appear in pairs in the momentum space with no ...exception. As a consequence, Fermi arcs occur on surfaces which connect the projections of the WPs with opposite chiral charges. However, this situation can be circumvented in the case of unpaired WP, without relevant surface Fermi arc connecting its surface projection, appearing singularly, while its Berry curvature field is absorbed by nontrivial charged nodal walls. Here, combining angle-resolved photoemission spectroscopy with density functional theory calculations, we show experimentally that a singular Weyl point emerges in PtGa at the center of the Brillouin zone (BZ), which is surrounded by closed Weyl nodal walls located at the BZ boundaries and there is no Fermi arc connecting its surface projection. Our results reveal that nontrivial band crossings of different dimensionalities can emerge concomitantly in condensed matter, while their coexistence ensures the net topological charge of different dimensional topological objects to be zero. Our observation extends the applicable range of the original Nielsen-Ninomiya no-go theorem which was derived from zero dimensional paired WPs with opposite chirality.
Deformation twinning plays a vital role in accommodating plastic deformation of hexagonal-close-packed (hcp) metals, but its mechanisms are still unsettled under high strain rate shock compression. ...Here we investigate deformation twinning in shock-compressed Mg as a typical hcp metal with in situ, ultrafast synchrotron x-ray diffraction. Extension twinning occurs upon shock compression along ⟨112over ¯0⟩ and ⟨101over ¯0⟩, but only upon release for loading along ⟨0001⟩. Such deformation mechanisms are a result of the polarity of deformation twinning, which depends on directionality and relative magnitude of resolved shear stress and may be common for Mg and its alloys in a wide range of strain rates.
ABSTRACT
High time resolution and accuracy are of critical importance in the studies of timing analysis and time delay localization of gamma-ray bursts (GRBs), soft gamma-ray repeaters (SGRs) and ...pulsars. The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) consisting of two micro-satellites, GECAM-A and GECAM-B, launched on 2020 December 10, is aimed at monitoring and locating X-ray and GRBs all over the sky. To achieve its scientific goals, GECAM is designed to have the highest time resolution (0.1 $\mu {\rm s}$) among all GRB detectors ever flown. Here, we make a comprehensive time calibration campaign including both on-ground and on-orbit tests to derive not only the relative time accuracy of GECAM satellites and detectors, but also the absolute time accuracy of GECAM-B. Using the on-ground calibration with a $\rm ^{22}Na$ radioactive source, we find that the relative time accuracy between GECAM-A and GECAM-B is about 0.15 $\mu {\rm s}$ (1σ). To measure the relative time accuracy between all detectors of a single GECAM satellite, cosmic-ray events detected on orbit are utilized since they could produce many secondary particles simultaneously record by multiple detectors. We find that the relative time accuracy among all detectors onboard GECAM-B is about 0.12 $\mu {\rm s}$ (1σ). Finally, we use the novel Li-CCF method to perform the absolute time calibration with Crab pulsar and SGR J1935+2154, both of which were jointly observed by GECAM-B and Fermi/GBM, and obtain that the time difference between GECAM-B and Fermi/GBM is 3.06 ± 6.04 $\mu {\rm s}$ (1σ).