A Compton camera is being developed for the purpose of ion-range monitoring during hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating fiber beam tagging ...hodoscope, a stack of double sided silicon strip detectors (90 Â 90 Â 2 mm 3 , 2 Â 64 strips) as scatter detectors, as well as bismuth germanate (BGO) scintillation detectors (38 Â 35 Â 30 mm 3 , 100 blocks) as absorbers. The individual components will be described, together with the status of their characterization.
Front end electronics and first results of the ALICE V0 detector Zoccarato, Y.; Tromeur, W.; Aguilar, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2011, Letnik:
626
Journal Article
Recenzirano
This paper gives a detailed description of the acquisition and trigger electronics especially designed for the V0 detector of ALICE at LHC. A short presentation of the detector itself is given before ...the description of the Front End Electronics (FEE) system, which is completely embedded within the LHC environment as far as acquisition (DAQ), trigger (CTP), and detector control (DCS) are concerned. It is able to detect on-line coincident events and to achieve charge (with a precision of 0.6 pC) and time measurements (with a precision of 100
ps). It deploys quite a simple architecture. It is however totally programmable and fully non-standard in discriminating events coming from Beam–Beam interaction and Beam-Gas background. Finally, raw data collected from the first LHC colliding beams illustrate the performance of the system.
Radiation effects on ALICE V0 detector components Cheynis, B.; Ducroux, L.; Grossiord, J.-Y. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2006, Letnik:
569, Številka:
3
Journal Article
Recenzirano
Odprti dostop
The 60
MeV proton beam delivered by the RADEF facility of the University of Jyväskylä (Finland) was used to measure the radiation effects on the counter components of the V0 detector of ALICE. There ...are the scintillator BC404, the wavelength shifting fibres BCF9929A and the optical fibres BCF98 from Bicron (Saint-Gobain). The light yield and the time resolution given by a counter of the inner ring of the V0C array, mounted within a dedicated device, were measured as a function of the radiation dose up to about 300
krad. A global light attenuation of the order of 30% can be anticipated during 10 years of ALICE running.
This paper presents our work on a 8-channel low noise Front-End electronic coupled to a Liquid Argon (LAr) TPC (Time Projection Chamber). Each channel consists of a Charge Sensitive Amplifier (CSA), ...a band pass filter and a 50 Ohms buffer as line driver. A serial link based on a `i2c-like' protocol, provides multiple configuration features to the circuit by accessing slow control registers. Only the CSA part is described in this paper. The feedback network of the CSA is made of a capacitance and a resistor. Their values are respectively 250 fF and 4 MΩ. An input referred noise of, at most, 1500 e-rms must be achieved at -100°C with an input detector capacitance of 250 pF to ensure a correct measurement of the minimal signal of 18000e-(2.88 fC). The power consumption in this cryogenic setup must be less than 40 mW from a 3.3 V power supply.