We present our seven-year experience of using moderate deep inspiration breath-hold (mDIBH) with an active breathing control (ABC) device for patients with early-stage breast cancer and dosimetric ...comparison to evaluate the benefit of mDIBH on the heart, lung, and liver.We retrospectively reviewed all patients with newly diagnosed breast cancer and having clinical stage Tis, I, or II disease treated between November 2010 and October 2017. Among the 369 patients included in this study, 107 patients were treated with mDIBH and 262 patients were treated with free breathing (FB). Dosimetric analysis was performed to compare dose distribution in the heart, lung, and liver between the two treatment groups. The chi-square test was used to compare the distribution of stage and tumor site between the two groups. The independent samples t-test was used to compare the remaining parameters between the two groups.For all 369 patients, there was a significantly lower ipsilateral lung V5 (relative volume receiving ≧5 Gy), ipsilateral lung V10, ipsilateral lung V20, mean ipsilateral lung dose, whole lung V5, whole lung V10, whole lung V20, mean whole lung dose, heart V10, heart V30, heart V40, and mean heart dose in the mDIBH group. For 184 patients with a left-sided breast tumor, significantly lower ipsilateral lung V5, ipsilateral lung V10, ipsilateral lung V20, mean ipsilateral lung dose, whole lung V10, whole lung V20, mean whole lung dose, heart V10, heart V30, heart V40, and mean heart dose were observed in the mDIBH group. For 185 patients with a right-sided breast tumor, significantly lower ipsilateral lung V5, ipsilateral lung V10, ipsilateral lung V20, mean ipsilateral lung dose, whole lung V5, whole lung V10, whole lung V20, mean whole lung dose, heart V10, heart V30, heart V40, mean heart dose, liver V30, and mean liver dose were observed in the mDIBH group.For early-stage breast cancer patients, mDIBH reduces not only the heart dose but also the lung and liver doses. The routine integration of mDIBH using an ABC device may decrease radiation-induced toxicity in the heart, lung, and liver.
Electromagnetic transponders bronchoscopically implanted near the tumor can be used to monitor deep inspiration breath hold (DIBH) for thoracic radiation therapy (RT). The feasibility and safety of ...this approach require further study.
We enrolled patients with primary lung cancer or lung metastases. Three transponders were implanted near the tumor, followed by simulation with DIBH, free breathing, and 4D-CT as backup. The initial gating window for treatment was ±5 mm; in a second cohort, the window was incrementally reduced to determine the smallest feasible gating window. The primary endpoint was feasibility, defined as completion of RT using transponder-guided DIBH. Patients were followed for assessment of transponder- and RT-related toxicity.
We enrolled 48 patients (35 with primary lung cancer and 13 with lung metastases). The median distance of transponders to tumor was 1.6 cm (IQR 0.6-2.8 cm). RT delivery ranged from 3 to 35 fractions. Transponder-guided DIBH was feasible in all but two patients (96% feasible), where it failed because the distance between the transponders and the antenna was >19 cm. Among the remaining 46 patients, 6 were treated prone to keep the transponders within 19 cm of the antenna, and 40 were treated supine. The smallest feasible gating window was identified as ±3 mm. Thirty-nine (85%) patients completed one year of follow-up. Toxicities at least possibly related to transponders or the implantation procedure were grade 2 in six patients (six incidences, cough and hemoptysis), grade 3 in three patients (five incidences, cough, dyspnea, pneumonia, and supraventricular tachycardia), and grade 4 pneumonia in one patient (occurring a few days after implantation but recovered fully and completed RT). Toxicities at least possibly related to RT were grade 2 in 18 patients (41 incidences, most commonly cough, fatigue, and pneumonitis) and grade 3 in four patients (seven incidences, most commonly pneumonia), and no patients had grade 4 or higher toxicity.
Bronchoscopically implanted electromagnetic transponder-guided DIBH lung RT is feasible and safe, allowing for precise tumor targeting and reduced normal tissue exposure. Transponder-antenna distance was the most common challenge due to a limited antenna range, which could sometimes be circumvented by prone positioning.
Introduction
One of the most feared side effects of radiotherapy (RT) in the setting of breast cancer (BC) patients is cardiac toxicity. This side effect can jeopardize the quality of life (QoL) of ...long-term survivors. The impact of modern techniques of RT such as deep inspiration breath hold (DIBH) have dramatically changed this setting. We report and discuss the results of the literature overview of this paper.
Materials and methods
Literature references were obtained with a PubMed query, hand searching, and clinicaltrials.gov.
Results
We reported and discussed the toxicity of RT and the improvements due to the modern techniques in the setting of BC patients.
Conclusions
BC patients often have a long life expectancy, thus the RT should aim at limiting toxicities and at the same time maintaining the same high cure rates. Further studies are needed to evaluate the risk–benefit ratio to identify patients at higher risk and to tailor the treatment choices.
Summary
Deep Inspiration Breath‐Hold (DIBH) techniques for breast cancer radiation therapy (RT) have reduced cardiac dose compared to Free Breathing (FB). Recently, a voluntary deep inspiration ...breath‐hold (vDIBH) technique was established using in‐room lasers and skin tattoos to monitor breath‐hold. An in‐house quality assessment of positional reproducibility during RT delivery with vDIBH in patients with left‐sided breast cancer was evaluated. The electronic portal imaging device (EPID) was used in cinematographic (CINE) mode to capture a sequence of images during beam delivery. Weekly CINE images were retrospectively assessed for 20 left‐sided breast cancer patients receiving RT in vDIBH, and compared with CINE images of 20 patients treated in FB. The intra‐beam motion was assessed and the distance from the beam central axis (CA) to the internal chest wall (ICW) was measured on each CINE image. These were then compared to the planned distance on digitally reconstructed radiograph (DRR). The maximum intra‐beam motion for any one patient measurement was 0.30 cm for vDIBH and 0.20 cm for FB. The mean difference between the distance from the CA to ICW on DRR and the equivalent distance on CINE imaging (as treated) was 0.28 cm (SD 0.17) for vDIBH patients and 0.25 cm (SD 0.14) for FB patients (P = 0.458). The measured values were comparable for patients undergoing RT in vDIBH, and for those in FB. This quality assessment showed that using in‐room lasers and skin tattoos to independently monitor breath‐hold in vDIBH as detected by ‘on‐treatment’ CINE imaging is safe and effective.
The present study was to investigate the usefulness of deep inspiration breath hold (DIBH) in bilateral breast patients using 6MV flattened beam (FB) and flattening filter free beam (FFFB).
Twenty ...bilateral breast cancer patients were simulated, using left breast patients treated with DIBH technique. CT scans were performed in the normal breathing (NB) and DIBH method. Three-dimensional conformal radiotherapy (3DCRT) and volumetric arc therapy (VMAT) plans were generated.
In our study the best organ at risk (OAR) sparing is achieved in the 3DCRT DIBH plan with adequate PTV coverage (V
≥ 47.5 Gy) as compared to 6MV FB and FFFB VMAT DIBH plans. The DIBH scan plan reduces the heart mean dose significantly at the rate of 49% in 3DCRT (p = 0.00) and 22% in VMAT (p = 0.010). Similarly, the DIBH scan plan produces lesser common lung mean dose of 18% in 3DCRT (p = 0.011) and 8% in VMAT (0.007) as compared to the NB scan. The conformity index is much better in VMAT FB (1.04 ± 0.04
. 1.04 ± 0.05), p =1.00 and VMAT FFFB (1.04 ± 0.05
. 1 ± 0.24, p = 0.345) plans as compared to 3DCRT (1.63 ± 0.2
. 1.47 ± 0.28, p = 0.002). The homogeneity index of all the plans is less than 0.15. The global dmax is more in VMAT FFFB DIBH plan (113.7%). The maximum MU noted in the NB scan plan (478
. 477MU, 1366
. 1299 MU and 1853
. 1788 MU for 3DCRT, VMAT FB and VMAT FFFB technique as compared to DIBH scan.
We recommend that the use of DIBH techniques for bilateral breast cancer patients significantly reduces the radiation doses to OARs in both 3DCRT and VMAT plans.
The addition of regional nodal radiation (RNI) to whole breast irradiation for high risk breast cancer improves metastases free survival and new data suggests it contributes additional benefit to ...overall survival. Deep inspiration breath hold (DIBH) has been shown to reduce cardiac and pulmonary dose in the context of left-sided disease treated with or without RNI, yet few studies have investigated its utility for right-breast cancer. This study investigates the potential advantages of DIBH in local and locoregional radiotherapy for right-sided breast cancer.
Free-breathing (FB) and DIBH computed tomography datasets were obtained from twenty patients who previously underwent radiotherapy for left-sided breast cancer. Ten patients were retrospectively planned for whole right breast only irradiation and ten patients were planned for irradiation to the whole breast plus ipsilateral supra-clavicular (SC) nodes, with and without irradiation of the ipsilateral internal mammary nodes (IMN). Dose-volume metrics for the clinical target volume, lungs, heart, left anterior descending artery, right coronary artery (RCA) and liver were recorded. Differences between FB and DIBH plans were analysed using Wilcoxon signed-rank tests, with P < 0.05 considered statistically significant.
DIBH increased the average total lung volume compared to FB in both breast only and breast plus RNI cohorts (P = 0.001). For the breast only group, there was no significant improvement in any ipsilateral lung dose-volume metric between FB and DIBH. However, for the breast plus RNI group, there was an improvement in ipsilateral lung mean dose (18.9 ± 3.2 Gy to 15.9 ± 2.3 Gy, P = 0.002) and V20Gy (45.3 ± 13.3% to 32.9 ± 9.4%, P = 0.002). In addition, DIBH significantly reduced the maximum dose to the RCA for RNI (11.6 ± 7.2 Gy to 5.6 ± 2.9 Gy, P = 0.03). Significant reductions in the liver V20Gy and maximum dose were observed in all cohorts during DIBH compared to FB.
DIBH is a promising approach for right-breast radiotherapy with considerable sparing of normal tissue, particularly when the ipsilateral IMNs are also irradiated.
Hodgkin lymphomas are radiosensitive and curable tumors that often involve the mediastinum. However, the application of radiation therapy to the mediastinum is associated with late effects including ...cardiac and pulmonary toxicities and secondary cancers. The adoption of conformal IMRT and deep inspiration breath- hold (DIBH) can reduce the dose to healthy normal tissues (lungs, heart and breast). We compared the dosimetry of organs at risk (OARs) using different IMRT techniques for two breathing conditions, i.e., deep inspiration breath hold (DIBH) and free breathing. Twenty-three patients with early-stage mediastinal Hodgkin lymphomas were accrued in the prospective study. The patients were given treatment plans which utilized full arc volumetric modulated arc therapy (F-VMAT), Butterfly VMAT (B-VMAT), and fixed field IMRT (FF-IMRT) techniques for both DIBH and free breathing methods, respectively. All the plans were optimized to deliver 95% of the prescription dose which was 25.2 Gy to 95% of the PTV volume. The mean dose and standard error of the mean for each OAR, conformity index (CI), and homogeneity index (HI) for the target using the three planning techniques were calculated and compared using Student's
-test for parametric data and Wilcoxon signed-rank test for non-parametric data. The HI and CI of the target was not compromised using the DIBH technique for mediastinal lymphomas. The mean values of CI and HI for both DIBH and FB were comparable. The mean heart doses were reduced by 2.1 Gy, 2.54 Gy, and 2.38 Gy in DIBH compared to FB for the F-VMAT, B-VMAT, and IMRT techniques, respectively. There was a significant reduction in V5Gy, V10Gy, and V15Gy to the heart (
< 0.005) with DIBH. DIBH reduced the mean dose to the total lung by 1.19 Gy, 1.47 Gy, and 1.3 Gy, respectively. Among the 14 female patients, there was a reduction in the mean right breast dose with DIBH compared to FB (4.47 Gy vs. 3.63 Gy,
= 0.004). DIBH results in lower heart, lung, and breast doses than free breathing in mediastinal Hodgkin Lymphoma. Among the different IMRT techniques, FF-IMRT, B-VMAT, and F-VMAT showed similar PTV coverage, with similar conformity and homogeneity indices. However, the time taken for FF-IMRT was much longer than for the F-VMAT and B-VMAT techniques for both breathing methods. B-VMAT and F-VMAT emerged as the optimal planning techniques able to achieve the best target coverage and lower doses to the OARs, with less time required to deliver the prescribed dose.
Deep inspiration breath-hold (DIBH) has been established to decrease normal tissue radiation dose in breast cancer.
Forty-nine patients had two CT scans during DIBH or free breathing. Chest-wall ...position, setup verification and breath-hold monitoring were performed. Cone-beam CT and a surface image system were used for verification.
A total of 1617 breath-holds were analyzed in 401 fractions. The mean time bit was 6.01 min. The mean breaths-holds per fraction was 4.96. The median for intra-breath hold variability was 3 mm. No patient stopped treatment for intolerance. Clinical target volume margins were calculated as 0.36, 0.36 and 0.32 for the three translational positions. The mean saved volume was 26.3%.
Voluntary DIBH is feasible, tolerable and easy to apply for children with Hodgkin lymphoma involving the mediastinum.
This study aimed to investigate preoperative spirometry and BMI as early predictors of the mean heart and lung dose (MHD, MLD) in deep inspiration breath-hold (DIBH) radiotherapy.
Left-sided breast ...cancer patients underwent breast-conserving surgery followed by DIBH radiotherapy enrolled. Patients who were not available for preoperative spirometry were excluded. One hundred eligible patients were performed free-breathing (FB-) CT and DIBH-CT for plan comparison. We completed the correlative and multivariate analysis to develop the linear regression models for dose prediction. The residuals were calculated to explore the unpreferable subgroups and compare the prediction accuracy.
Among the parameters, vital capacity (VC) and BMI showed the strongest negative correlation with MHD (r = - 0.33) and MLD (r = - 0.34), respectively. They were also significant in multivariate analysis (P < 0.001). Elderly and less VC were independent predictors of increasing absolute residuals (AR). The VC model showed no significant difference in AR compared to the model using the CT parameter of lung volume in FB (LV-FB): median AR of the LV-FB model vs. the VC model was 0.12 vs. 0.11 Gy (P = 0.79). On the other hand, the median AR of the MLD model was 0.38 Gy, showing no specific subgroups of larger AR.
Preoperative spirometry and BMI are significant predictors of MHD and MLD, respectively. Although elderly and low-VC patients may have larger predictive variations, spirometry might be a substitute for LV-FB as a predictor of MHD.
Purpose
The purpose of this study was to compare two techniques of irradiation of left-sided breast cancer patients who underwent breast-conserving surgery, three-dimensional conformal radiotherapy ...technique (3D-CRT) and volumetric modulated arc therapy (VMAT), in terms of dose distribution in the planning target volume (PTV) and organs at risk (OARs). The second aim of the study was estimation of the projected risk of radiation-induced secondary cancer for both radiotherapy techniques.
Materials and methods
For 25 patients who underwent CT simulation in deep inspiration breath-hold (DIBH), three treatment plans were generated: one using a three-dimensional conformal radiotherapy technique and two using volumetric modulated arc therapy. First VMAT-DIBH geometry consisted of three partial arcs (ARC-DIBH 3A) and second consisted of four partial arcs (ARC-DIBH 4A). Cumulative dose–volume histograms (DVHs) were used to compare dose distributions within the PTV and OARs (heart, left anterior descending coronary artery LAD, ipsilateral and contralateral lung IL, CL, and contralateral breast CB). Normal tissue complication probabilities (NTCPs) and organ equivalent doses (OEDs) were calculated using the differential DVHs. Excess absolute risks (EARs) for second cancers were estimated using Schneider’s full mechanistic dose–response model.
Results
All plans fulfilled the criterium for PTV V95% ≥ 95%. The PTV coverage, homogeneity, and conformity indices were significantly better for VMAT-DIBH. VMAT showed a significantly increased mean dose and V5Gy for all OARs, but reduced LAD D
max
by 15 Gy. For IL, CL, and CB, the 3D-CRT DIBH method achieved the lowest values of EAR: 28.38 per 10,000 PYs, 2.55 per 10,000 PYs, and 4.48 per 10,000 PYs (
p
< 0.001), compared to 40.29 per 10,000 PYs, 15.62 per 10,000 PYs, and 23.44 per 10,000 PYs for ARC-DIBH 3A plans and 41.12 per 10,000 PYs, 15.59 per 10,000 PYs, and 22.73 per 10,000 PYs for ARC-DIBH 4A plans. Both techniques provided negligibly low NTCPs for all OARs.
Conclusion
The study shows that VMAT-DIBH provides better OAR sparing against high doses. However, the large low-dose-bath (≤ 5 Gy) is still a concern due to the fact that a larger volume of normal tissues exposed to lower doses may increase a radiation-induced risk of secondary cancer.