This study examines the influence of textile substrates upon the behavior of wearable screen‐printed electrodes and demonstrates the attractive sensing properties of these sensors towards the ...detection of nitroaromatic explosives. Compared to electrodes printed on common cotton or polyester substrates, GORE‐TEX‐based electrochemical sensors display reproducible background cyclic voltammograms, reflecting the excellent water‐repellant properties of the GORE‐TEX fabric. The wetting properties of different printed textile electrodes are elucidated using contact angle measurements. The influence of laundry washing and mechanical stress is explored. The GORE‐TEX‐based printed electrodes exhibit favorable detection of 2,4‐dinitrotoluene (DNT) and 2,4,6‐trinitrotoluene (TNT) explosives, including rapid detection of DNT vapor.
Woe from wit Griboyedov, Aleksandr Sergeyevich; Hulick, Betsy
2020, 2020-04-14
eBook
Alexander Griboedov's Woe from Wit is one of the masterpieces of Russian drama. A verse comedy set in Moscow high society after the Napoleonic wars, it offers sharply drawn characters and clever ...repartee, mixing meticulously crafted banter and biting social critique.
Objectives/Hypothesis
To describe an alternative approach to medialization thyroplasty involving dissection underneath the thyroid cartilage with placement of a Gore‐Tex implant, and to evaluate its ...effect on a range of phonatory measures using an excised canine larynx model.
Study Design
Animal model.
Methods
On each of eight excised canine larynges, the conditions of normal, paralysis, medialization thyroplasty by standard transthyroid cartilage approach, and medialization thyroplasty by experimental subthyroid cartilage approach were performed. Aerodynamic, acoustic, and mucosal wave parameters were measured for each condition.
Results
Compared to the vocal fold paralysis state, both the transthyroid and subthyroid approaches for Gore‐Tex insertion resulted in significant decreases in phonation threshold pressure and phonation threshold flow. Both approaches also significantly decreased percent jitter, decreased percent shimmer, and improved signal‐to‐noise ratio. The mucosal wave was preserved after insertion of the Gore‐Tex implant for both approaches. For all the phonatory measures except phonation threshold flow, there were no significant differences between the transthyroid and subthyroid approaches.
Conclusions
Gore‐Tex implantation via a subthyroid approach in an excised canine larynx model can produce effective medialization, preserve the mucosal wave, and significantly improve aerodynamic and acoustic parameters without meaningful difference compared to a traditional transthyroid approach. The subthyroid approach does not require creation of a thyroid cartilage window and could be a potentially valuable alternative method of performing medialization thyroplasty.
Level of Evidence
NA. Laryngoscope, 128:675–681, 2018
Both autologous costal cartilage (ACC) and alloplastic materials are widely used in rhinoplasty. However, there is controversy regarding which material can offer the ideal outcome and fewer ...complications.
The authors review current literature to evaluate complication and satisfaction rates with different materials used in rhinoplasty.
A comprehensive literature search of articles was conducted in Embase and PubMed published through April 14, 2017. We included only articles that used ACC, silicone, Medpor, Gore-Tex, or a combination of autologous and alloplastic materials in rhinoplasty. The primary outcomes analyzed were complications and postoperative satisfaction. After data extraction, meta-analysis using the random effect model was performed to summarize outcome parameters among different implant types.
Fifty-three articles met inclusion criteria and were included in the meta-analysis. The overall complication rate of ACC was 14%, which was higher than that of other implants. However, ACC was more commonly used in revision rhinoplasty. Medpor was associated with low overall complication rates (6%) and good aesthetic and functional outcomes.
Our analysis of available evidence suggests that ACC is preferred in revision rhinoplasty, which may explain its association with higher complication rates. In primary rhinoplasty, Medpor offered versatility in addition to low complication rates and good aesthetic and function outcomes. But its potential dramatic damage to the nasal tissue made secondary surgery extremely difficult. Our findings were limited by lack of high-quality evidence. Future studies with rigorous study design for head-to-head comparisons and longer follow-up are needed to establish clear guidelines for choosing the appropriate rhinoplasty graft material.
An 82-year-old man with a secundum atrial septal defect (ASD) underwent transcatheter closure. The patient had a wide area of aortic and superior rim deficiency, with left ventricular diastolic ...dysfunction and moderate mitral regurgitation. These findings suggested the risk of both cardiac erosion and increased left atrial pressure after closure. To avoid cardiac erosion, a GORE® CARDIOFORM ASD (GCA) occluder (W.L. Gore & Associates, Flagstaff, AZ, USA) was considered an appropriate device in this patient. However, the possibility of excessively high left atrial pressure due to complete defect closure was a concern. Thus, we created a 4.5-mm fenestration using a surgical punch in the fabric membrane of a 44-mm GCA. The device was deployed in an appropriate position, and no significant elevation of pulmonary capillary wedge pressure was observed. One month after the closure, marked improvement in clinical symptoms and continuous flow through the fenestration were observed. This novel fenestration technique may contribute to expansion of the indications for transcatheter ASD closure in patients who require a GCA owing to an anatomically high risk of erosion accompanied by left ventricular diastolic dysfunction.
In elderly patients with left ventricular diastolic dysfunction, transcatheter atrial septal defect (ASD) closure is difficult because rapid resolution of an ASD shunt can cause an increase in left atrial pressure. Previous reports described the creation of a fenestration in the closure device. The use of a GORE® CARDIOFORM ASD (GCA) occluder can reduce the erosion risk; however, creating a stable fenestration is difficult. We developed a novel technique to create a stable fenestration in a GCA.
Arytenoid edema is not a well-described complication of thyroplasty. We report a case of exuberant arytenoid edema following thyroplasty in a 33-year-old female. The diagnosis was made post-operative ...day 1, the patient was immediately started on a 6-day course of methylprednisone with voice rest. The arytenoid edema completely resolved within 1 week.
Patent foramen ovale (PFO) is a flaplike opening in the fossa ovalis; between the septum primum and secundum. It is highly prevalent with approximately 25% of the population having a PFO. It is ...usually asymptomatic but can rarely cause paradoxical embolism leading to stroke and/or significant right to left shunting causing hypoxia. The complications of PFO closure with a percutaneous device include embolization, cardiac perforation, and thrombosis. These are all early complications. We describe the case of a patient with a history of PFO closure who had device thrombosis 3 years after implantation. Management includes anticoagulation with warfarin. Repeat cardiac imaging to document the resolution of thrombosis is recommended.