Controlling the expansion of capture capacity has been a major challenge for the fisheries management systems around the North Atlantic. Despite focused attempts to reduce this capacity in recent ...years in different jurisdictions, it has continued to expand. This chapter uses a case study of changes in Norwegian fisheries to help explain why this has happened. The article supports the replacement of the rational actor approach that is currently hegemonic within fisheries management by a relational approach to the analysis of capture capacity expansion. A relational approach offers new insights into the ways political, economic, and technological forces continue to fuel capacity expansion within fishing. By use of this approach the article describes how the harvest machinery comes into existence.
Abstract
Die Durchstanzbemessung stahlfaserverstärkter Flachdecken erfolgt derzeit in Deutschland anhand der bauaufsichtlich eingeführten Richtlinie „Stahlfaserbeton” des Deutschen Ausschuss für ...Stahlbeton (DAfStb). Die Zugabe von Stahlfasern in den Beton ermöglicht nach dem Eintreten der Rissbildung eine effektive Zugkraftübertragung über den Riss hinweg und begrenzt die fortschreitende Rissöffnung, was sich für die Durchstanztragfähigkeit von Flachdecken als besonders günstig erweist. Zahlreiche Untersuchungen seit Mitte der 1970er Jahre bestätigten dies und ermöglichten die Ableitung empirischer und teils mechanisch basierter Ansätze zur rechnerischen Erfassung der Fasertragwirkung beim Nachweis einer ausreichenden Durchstanztragfähigkeit ohne Durchstanzbewehrung.
Zur Bewertung und Weiterentwicklung dieser Ansätze wurde eine Datenbank zu Durchstanzversuchen an stahlfaserverstärkten Flachdecken ohne Durchstanzbewehrung aufgebaut. Unter Beachtung der zugrunde gelegten baupraktischen Anforderungen in Bezug auf die Plattendicke, den Längsbewehrungsgrad sowie die Betondruck‐ und die Nachrisszugfestigkeit konnten etwa 116 Versuche in die Durchstanz‐Datenbank „Stahlfaserbeton” aufgenommen werden. Dieser Beitrag stellt die Datenbank vor und diskutiert deren Auswertung hinsichtlich der Vorhersagegenauigkeit und des Sicherheitsniveaus der Bemessungsansätze nach der DAfStb‐Richtlinie „Stahlfaserbeton” sowie nach Model Code 2010.
Abstract
Database for punching shear resistance of steel fibre reinforced concrete flat slabs without shear reinforcement – Verification of design approaches according to DAfStb guideline and Model Code 2010
The punching shear design of steel fibre‐reinforced flat slabs is currently carried out in Germany based on the DAfStb Guideline ”Steel fibre reinforced concrete“. The addition of steel fibres to the concrete allows an effective transfer of tensile forces across the crack and limits the progressive crack opening, which proves to be particularly favourable for the punching shear strength. Numerous investigations since the mid‐1970s have confirmed this and have enabled the derivation of empirical and partly mechanically based approaches for the calculation of the steel fibre contribution in the punching shear capacity of steel fibre reinforced flat slabs without punching shear reinforcement. For the evaluation and further development of these approaches, a critically reviewed database of punching shear tests on steel fibre reinforced flat slabs without punching shear reinforcement was created. Considering the practical construction requirements regarding the slab thickness, the degree of longitudinal reinforcement as well as the concrete compressive strength and the post‐cracking tensile strength, about 116 tests could be included in the punching shear database ”Steel fibre reinforced concrete“. This paper presents the database and discusses its evaluation about the prediction accuracy and the safety level of the design approaches according to the DAfStb guideline ”Steel fibre reinforced concrete“ as well as according to the Model Code 2010.
Abstract
Rissbreiten in Stahlbetonbauteilen vergrößern sich unter Langzeitbeanspruchung durch das zeitabhängige Materialverhalten des Betons. Während viele Rissbreitenansätze das Betonschwinden bei ...der Rissbreitenberechnung vernachlässigen, zeigen Untersuchungen in der Literatur, dass Schwinddehnungen bei der Rissbreitenberechnung berücksichtigt werden sollten. Um die einzelnen Effekte aus Schwinden, Verbund‐ und Betonkriechen auf das Rissbild einzuordnen, wurden die verschiedenen Anteile unter einer Lastbeanspruchung analysiert. Hierzu wurde im abgeschlossenen Rissbild eine Parameteranalyse mit einem an experimentellen Versuchen validierten rheologischen Modell durchgeführt und der Anteil des Betonschwindens an der Rissbreitenvergrößerung festgestellt. Ein Vergleich mit dem Rissbreitenansatz des Model Code 2010 zeigt, dass der Ansatz des Model Code 2010 potenziell gut geeignet ist, zeitabhängige Effekte wirklichkeitsnah abzubilden, diese allerdings überschätzt. Aus diesem Grund wurde der Ansatz modifiziert, sodass in einem weiteren Vergleich sehr gute Ergebnisse erzielt wurden, ohne die in der Praxis etablierte Rissbreitenformel grundlegend zu verändern.
Abstract
Influence of concrete shrinkage on crack widths in reinforced concrete members under direct loading
Under long‐term loading, crack widths in reinforced concrete members increase due to the time‐dependent material behaviour of concrete. While many crack width approaches neglect shrinkage in crack width calculations, investigations in the literature indicate that shrinkage strains should be taken into account for crack width calculation. In order to classify the individual effects of shrinkage, bond creep and concrete creep on the crack pattern, they were analysed separately under direct loading. For this purpose, a parameter analysis was performed in the stabilized cracking stage with a rheological model validated by experimental tests to determine the proportion of concrete shrinkage on crack width increase. A comparison with the crack width approach of Model Code 2010 shows that the approach of Model Code 2010 is potentially well suited to describe time‐dependent effects realistically, but overestimates them. For this reason, the approach was modified without fundamentally changing the established crack width formula. With that modification, very good results were achieved in a further comparison.
Abstract
Mit dem Ziel, einen Überblick über aktuelle normative Modelle zur Berechnung der Rissbreite im Stahlbetonbau zu erhalten, wurden diese am iBMB, Fachgebiet Massivbau der TU Braunschweig ...zusammengestellt und verglichen. Um einen unabhängigen Vergleich der Modelle sicherzustellen, wurde eine Datenbasis mit Versuchswerten zu Rissbreiten zusammengestellt. Der Modellvergleich wurde auf zentrische Zugversuche, bei denen charakteristische Werte der gemessenen Rissbreiten (95 %‐Quantilwerte) angegeben waren bzw. ermittelt werden konnten, beschränkt. Durch die Vergleichsberechnungen konnte gezeigt werden, dass zwischen den unterschiedlichen Modellen signifikante Abweichungen auftreten. Während der Eurocode 2 die im Versuch gemessenen Rissbreiten tendenziell überschätzt, werden die Rissbreiten mit den Nationalen Anhängen für Deutschland bzw. Österreich überwiegend unterschätzt. Mit dem Modell nach Model Code 2010 werden die Versuchsergebnisse im Mittel ebenfalls überschätzt, die Ergebnisse liegen jedoch zwischen denen nach Eurocode 2 sowie den Nationalen Anhängen für Deutschland bzw. Österreich. Des Weiteren kann mit den Modellen der Nationalen Anhänge für Deutschland und Österreich sowie des Model Code 2010 eine, gegenüber dem Eurocode 2, erhöhte Vorhersagegenauigkeit erreicht werden.
Abstract
Comparison of code provisions for the calculation of crack widths
In order to give an overview of current code provisions for the calculation of crack widths, these provisions were compiled and compared at the iBMB, Department of Concrete Construction of TU Braunschweig. In order to ensure an independent comparison, a database with test values for crack widths was compiled. The comparative calculations were limited to tensile tests in which characteristic values of the measured crack widths (95 %‐quantile values) were or could be determined. As a result, it can be stated that significant deviations occurred for the different code provisions. While the provisions by Eurocode 2 tend to overestimate the test values, the National Annexes for Germany and Austria mainly underestimate the measured crack widths. Model Code 2010 also overestimates the test results on average, but the results are between those obtained with Eurocode 2 and the national annexes for Germany and Austria. Furthermore, the models in the national annexes for Germany and Austria as well as the Model Code 2010 achieve a higher prediction accuracy than Eurocode 2.
Abstract
Mit der bauaufsichtlichen Einführung des Eurocode 2 in Deutschland wurde die Durchstanzbemessung von Flachdecken neu geregelt. Seitdem ergibt sich die Durchstanztragfähigkeit mit ...Durchstanzbewehrung aus der Summe eines konstanten Betontraganteils und eines Stahltraganteils, der unabhängig vom Bauteil aus einem 33°‐Fachwerk resultiert. Für die Berechnung des Stahltraganteils wird gemäß Eurocode 2 eine reduzierte Stahlfestigkeit in Abhängigkeit von der statischen Nutzhöhe angesetzt, wodurch die Verankerungsqualität der Durchstanzbewehrung berücksichtigt wird. Auf Basis einer Datenbankauswertung und eines Vergleichs des Sicherheitsniveaus mit der damaligen DIN 1045‐1 wurden im Deutschen Anhang zum Eurocode 2 (EC2+NA(D)) zusätzliche Erhöhungsfaktoren für die ersten beiden Durchstanzbewehrungsreihen ergänzt, die nahezu zu einer Verdopplung der Durchstanzbewehrungsmenge führen. Während zur Bewertung der Bemessungsgleichungen für die Ermittlung der Durchstanztragfähigkeit ohne Durchstanzbewehrung und auf dem Niveau der maximalen Durchstanztragfähigkeit zahlreiche Versuchsergebnisse vorliegen, sind bislang nur sehr wenige Versuchsreihen an Flachdeckenausschnitten mit einem Durchstanzversagen innerhalb des durchstanzbewehrten Bereichs vorhanden.
Zur systematischen Untersuchung des Durchstanztragverhaltens von Flachdecken mit Bügeln als Durchstanzbewehrung wurden daher insgesamt drei Versuchsserien mit variierenden Durchstanzbewehrungsgraden durchgeführt. Das Versuchsprogramm umfasste drei Referenzversuche ohne Durchstanzbewehrung und acht Versuchskörper mit geringen und mittleren Durchstanzbewehrungsgraden. Dabei erfolgte die Variation der Durchstanzbewehrungsmenge jeweils ausschließlich über den Bügeldurchmesser. Weitere untersuchte Einflussparameter waren die Schubschlankheit und die statische Nutzhöhe. Im vorliegenden Beitrag werden die durchgeführten Versuche vorgestellt und die Versuchsergebnisse diskutiert. Durch den Vergleich der experimentell ermittelten Bruchlasten mit den rechnerischen Durchstanztragfähigkeiten nach Eurocode 2 und EC2+NA(D) können die bestehenden normativen Regeln bewertet werden. Darüber hinaus werden die Bemessungsregeln nach Model Code 2010 in die Bewertung mit einbezogen.
Abstract
Punching strength of flat slabs with varying shear reinforcement ratios
With the introduction of Eurocode 2 in Germany, the punching shear design provisions of flat slabs were revised. Since then, the punching shear strength with shear reinforcement is calculated from the combination of a constant concrete contribution and a steel contribution, which results from a strut inclination of 33°. Besides, a reduced steel strength depending on the effective depth of the flat slab is assumed for the calculation of the steel contribution to consider the anchorage conditions of the shear reinforcement elements. Due to a database analysis and an evaluation of the level of safety compared to the former DIN 1045‐1, additional factors have been implemented in German Annex to Eurocode 2 (EC2+NA(D)) for the first and second row of shear reinforcement leading to almost twice the amount of required shear reinforcement. Various test series on reinforced concrete flat slabs without shear reinforcement and with high amounts of shear reinforcement are available and can be used for the evaluation of the current provisions. Nevertheless, the evaluation of the code equations for the design of the shear reinforcement (failure inside the shear‐reinforced zone) is still not possible since only very few systematic punching tests with a varying amount of shear reinforcement have been conducted.
To investigate the punching shear behavior of reinforced concrete flat slabs with stirrups as shear reinforcement, three systematic test series (eleven specimens) with varying shear reinforcement ratios were performed. Each test series included one reference test without shear reinforcement. In the tests, the shear reinforcement ratio was varied by changing the stirrup diameter only. Further investigated influences were the shear span‐depth ratio and the effective depth. In this paper, the results of the tests are presented, discussed and compared to the predictions according to Eurocode 2 and EC2+NA(D). Moreover, the punching design provisions according to Model Code 2010 are evaluated.
Abstract
Mit Model Code 2010 wurde ein neues Bemessungskonzept für den Durchstanznachweis vorgestellt, welches auf der Theorie der kritischen Schubrissbreite (
Critical Shear Crack Theory
) basiert. ...Im Rahmen dieses Beitrags werden die Durchstanzwiderstände nach Model Code 2010, Eurocode 2 und den Regelungen des deutschen Anhangs zu Eurocode 2 vorgestellt und um Hintergrundinformationen ergänzt. Anhand von Parameterrechnungen und der Nachrechnungen von Durchstanzversuchen erfolgt ein Vergleich der unterschiedlichen Bemessungskonzepte. Dabei werden Sicherheitsdefizite identifiziert und die Auswirkungen unterschiedlicher Einflussparameter auf die Durchstanztragfähigkeit von Flachdecken‐Stützenknoten herausgearbeitet.
Comparison of punching shear design according to Model Code 2010 and Eurocode 2
Model Code 2010 introduces a new design concept for punching shear, which bases on the so‐called Critical Shear Crack Theory. In this paper, the design provisions for punching shear according to Model Code 2010, Eurocode 2 and the corresponding German National Annex to Eurocode 2 are presented and background information is given. By means of parameter studies and a comparison of the calculated resistances to test result, the different punching shear design provisions are critically reviewed. The safety levels of the code provisions are verified and the influence of the different punching parameters on the calculated resistances is examined in detail.