  • Bayesian model updating of eight-storey CLT building using modal data
    Kurent, Blaž, 1994- ...
    The serviceability of tall timber buildings due to wind-induced vibrations is often a governing design criterion. However, accurate modelling of such buildings for their serviceability is a ... challenge, partly because certain non-structural building elements (e.g. plasterboards, façade, screed) act structurally, and no guidelines exist on how to effectively include them in the model. Model updating may be helpful in revealing their as-built characteristics. This paper presents findings of a surrogate-based Bayesian model updating of a lightweight eight-storey cross-laminated-timber building. In particular, the focus was on patterns and correlations between mass distribution and modal characteristics, as well as the effects of joints, non-structural building elements, and the foundation. Model updating utilised the results of ambient vibration testing, which is commonly used in civil engineering for structural identification or health monitoring, however, it generally offers a relatively low number of identified modes. To this end, the study investigates the sensitivity of the updating process to the number of modes involved in the analysis.
    Vir: Probabilistic engineering mechanics. - ISSN 0266-8920 (Vol. 77, art. 103642, July 2024, str. 1-13)
    Vrsta gradiva - članek, sestavni del
    Leto - 2024
    Jezik - angleški
    COBISS.SI-ID - 200412675

vir: Probabilistic engineering mechanics. - ISSN 0266-8920 (Vol. 77, art. 103642, July 2024, str. 1-13)