Gassanov, Natig; Mutallimov, Mirza; Caglayan, Evren; Erdmann, Erland; Er, Fikret
Journal of cardiology, December 2022, 2022-12-00, 20221201, Letnik: 80, Številka: 6Journal Article
The wearable cardioverter defibrillator (WCD) is increasingly used in patients at elevated risk for ventricular arrhythmias but not fulfilling the indications for an implantable cardioverter defibrillator (ICD). Currently, there is an insufficient risk prediction of fatal arrhythmias in patients at risk. In this study, we assessed the prognostic role of baseline electrocardiogram (ECG) in WCD patients. WCD patients from diverse clinical institutions in Germany (n = 227) were retrospectively enrolled and investigated for the incidences of death or ventricular arrhythmias during WCD wearing. In addition, the widely accepted ECG predictors of adverse outcome were analyzed in patients with arrhythmic events. Life-threatening arrhythmias occurred in 22 (9.7 %) patients, mostly in subjects with ischemic heart disease (15 of 22). There was no difference in baseline left ventricular ejection fraction (LVEF) in subjects with and without arrhythmic events (31.3 ± 7.9 % vs. 32.6 ± 8.3 %; p = 0,24). Patients with arrhythmia exhibited significantly longer QRS duration (109.5 ± 23.1 ms vs. 100.6 ± 22.3 ms, p = 0,04), Tpeak-Tend (Tp-e) (103.1 ± 15.6 ms vs. 93.2 ± 19.2 ms, p = 0,01) and QTc (475.0 ± 60.0 ms vs. 429.6 ± 59.4 ms, p < 0,001) intervals. In contrast, no significant differences were found for incidences of fragmented QRS (27.3 % vs. 24 %, p = 0.79) and inverted/biphasic T-waves (16.6 % vs. 22.7 %, p = 0,55). In multivariate regression analysis both Tp-e (HR 1.03; 95 % CI 1.001–1.057; p = 0.02) and QTc (HR 1.02; 95 % CI 1.006–1.026; p < 0.001) were identified as independent predictors of ventricular arrhythmias. After WCD use, the prophylactic ICD was indicated in 76 patients (33 %) with uneventful clinical course but persistent LVEF ≤35 %. The ECG analysis in these subjects did not reveal any relevant changes in arrhythmogenesis markers. ECG repolarization markers Tp-e and QTc are associated with malignant arrhythmias in WCD patients and may be used - in addition to other established risk markers - to identify appropriate patients for ICD implantation. Display omitted •The wearable cardioverter defibrillator is safe and effective in patients with elevated risk for fatal arrhythmias.•Tp-e and QTc are independent electrocardiographic (ECG) predictors of adverse events in these patients.•ECG can serve as an additional risk stratification tool in this high-risk subgroup.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.