E-viri
Recenzirano
-
De Palma, Giovanni D., MD; Giglio, Mariano C., MD; Bruzzese, Dario, PhD; Gennarelli, Nicola, MD; Maione, Francesco, MD; Siciliano, Saverio, MD; Manzo, Benedetta, MD; Cassese, Gianluca, MD; Luglio, Gaetano, MD
Gastrointestinal endoscopy, 01/2018, Letnik: 87, Številka: 1Journal Article
Background and Aims EndoCuff is a disposable device applied to standard colonoscopes to improve mucosal visualization. Randomized parallel trials have shown that EndoCuff increases the adenoma detection rate (ADR). The primary aim of this study was to compare the ADR between EndoCuff-assisted colonoscopies (EAC) and standard colonoscopies within a randomized back-to-back trial. Methods This was a single-center randomized crossover study (NCT02374515) involving adult patients undergoing screening, surveillance, or diagnostic colonoscopy. Participants received back-to-back standard colonoscopies and EACs in a random order, performed by the same endoscopist. All polyps were excised, but only those proven at histology to be adenomas were considered for analysis. Results From February 2015 to March 2016, a total of 288 patients were enrolled, and 274 were included in the per-protocol analysis. Compared with standard colonoscopies, EACs increased the ADR (29.6% vs 26.3%; P < .01) and the number of diagnosed adenomas (176 vs 129; P < .01), particularly in the left (73 vs 46; P < .01) and right sides of the colon (83 vs 63; P < .01). EAC increased the detection of adenomas <5 mm (129 vs 84; P < .01), but no difference was found with regard to larger lesions. In 7.3% of patients, findings of EndoCuff shortened the surveillance interval determined by standard colonoscopy findings. EndoCuff caused 7 mucosal erosions (2.5% of patients), requiring a mucosal adrenaline injection in 1 case. Conclusions The use of EndoCuff increases the number of identified adenomas, primarily small adenomas in the left and right sides of the colon. This increases the ADR and allows a better definition of the surveillance program. (Clinical trial registration number: NCT02374515 .)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.