E-viri
Recenzirano
Odprti dostop
-
Figdore, Daniel J.; Wiste, Heather J.; Bornhorst, Joshua A.; Bateman, Randall J.; Li, Yan; Graff‐Radford, Jonathan; Knopman, David S.; Vemuri, Prashanthi; Lowe, Val J.; Jr, Clifford R. Jack; Petersen, Ronald C.; Algeciras‐Schimnich, Alicia
Alzheimer's & dementia : diagnosis, assessment & disease monitoring, January‐March 2024, Letnik: 16, Številka: 1Journal Article
INTRODUCTION This study evaluated the performance of the Lumipulse plasma beta‐amyloid (Aβ) 42/40 and pTau181 compared to other assays to detect an abnormal amyloid‐positron emission tomography (PET). METHODS Plasma samples from cognitively unimpaired (N = 179) and MCI/AD dementia (N = 36) individuals were retrospectively evaluated. Plasma Aβ42/40 and pTau181 were measured using the Lumipulse and Simoa immunoassays. An immunoprecipitation mass spectrometry (IP‐MS) assay for plasma Aβ42/40 was also evaluated. Amyloid‐PET status was the outcome measure. RESULTS Lumipulse and IP‐MS Aβ42/40 exhibited the highest diagnostic accuracy for detecting an abnormal amyloid‐PET (areas under the curve AUCs of 0.81 and 0.84, respectively). The Lumipulse and Simoa pTau181 assays exhibited lower performance (AUCs of 0.74 and 0.72, respectively). The Simoa Aβ42/40 assay demonstrated the lowest diagnostic accuracy (AUC 0.57). Combining Aβ42/40 and pTau181 did not significantly improve performance over Aβ42/40 alone for Lumipulse (AUC 0.83) or over pTau181 alone for Simoa (AUC 0.71) DISCUSSION The Lumipulse Aβ42/40 assay showed similar performance to the IP‐MS Aβ42/40 assay for detection of an abnormal amyloid‐PET; and both assays performed better than the two p‐tau181 immunoassays. The Simoa Aβ42/Aβ40 assay was the least accurate at predicting an abnormal amyloid‐PET status. Highlights Lumipulse plasma Aβ42/Aβ40 AUC for abnormal amyloid‐PET detection was 0.81. This performance was comparable to previously reported IP‐MS and higher than Simoa. Performance of Alzheimer's disease blood biomarkers varies between assays.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.