  • An Inner Current Suppressin...
    Li, Zixin; Wang, Ping; Chu, Zunfang; Zhu, Haibin; Luo, Yongjie; Li, Yaohua

    IEEE transactions on power electronics, 11/2013, Letnik: 28, Številka: 11
    Journal Article

    Ideally, the inner (the upper or lower arm) current of a modular multilevel converter (MMC) is ideally assumed to be the sum of a dc component and an ac component of the fundamental frequency. However, as ac current flows through the submodule (SM) capacitors, the capacitor voltages fluctuate with time. Consequently, the inner current is usually distorted and the peak/RMS value of it is increased compared with the theoretical value. The increased currents will increase power losses and may threaten the safe operation of the power devices and capacitors. This paper proposes a closed-loop method for suppression of the inner current in an MMC. This method is very simple and is implemented in a stationary frame, and no harmonic extraction algorithm is needed. Hence, it can be applied to single-phase or three-phase MMCs. Besides, this method does not influence the balancing of the SM capacitor voltages. Simulation and experimental results show that the proposed method can suppress the peak and RMS values of the inner currents dramatically.