E-viri
Recenzirano
Odprti dostop
-
Hara, K.; Abidi, S.H.; Affolder, A.A.; Allport, P.; Basso, M.J.; Casha, A.; Cindro, V.; Ciungu, B.M.; Dette, K.; Escobar, C.; Fadeyev, V.; Freeman, P.; Garcia, C.; Gonella, L.; Gunnell, J.; Harada, D.; Helling, C.; Hunter, A.; Kisliuk, D.; Kopsalis, I.; Kroll, J.; Lacasta, C.; Latonova, V.; Mandić, I.; Martinez-Mckinney, F.; Mikestikova, M.; Miñano, M.; Nakamura, K.; Nicolini, J.; Onaru, K.; Orr, R.S.; Pyatt, S.; Saito, K.; Sato, K.; Simpson-Allsop, C.; Soldevila, U.; Teuscher, R.; Thomas, J.; Unno, Y.; Wada, S.; Worm, S.; Zatocilova, I.
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 12/2020, Letnik: 983, Številka: CJournal Article
The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40<R<100 cm in the radial and |z|<300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n+-on-p 6-inch wafer technology, for a total of 22,000 wafers. Intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90Sr β-rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm ×1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 1015 neq/cm2. The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300μm (standard) and 240μm (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.
Avtor
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.