E-viri
Recenzirano
-
Kuo, Jenn-Kun; Jiang, Wei-Zhe; Li, Chun-Han; Hsu, Tzu-Hsuan
Applied thermal engineering, 03/2020, Letnik: 169Journal Article
•Integrated simulation framework consisting of COMSOL and Simulink models.•Hydrogen supply stability and recovery performance of a PEMFC system.•A lower ejector temperature is disadvantageous in removing the moisture content.•Passive Venturi ejector to perform hydrogen recovery significantly reduces the time required. In traditional PEM fuel cells (PEMFCs), the unreacted hydrogen gas at the anode outlet is recovered using a mechanical pump or centrifuge and returned to the inlet side for reuse. However, the energy consumed by the pump reduces the system efficiency. Accordingly, the present study considers a 3-kW PEMFC in which the unreacted hydrogen gas is recovered passively from the exhaust stream using a Venturi ejector. An integrated simulation framework is constructed consisting of a COMSOL model of the ejector unit and a MATLAB/Simulink model of the hydrogen recovery system. The simulation framework is used to examine the temperature, pressure and velocity distributions within the ejector for various values of the inlet hydrogen pressure. The stability of the hydrogen supply in PEMFC systems incorporating a passive ejector system and a traditional mechanical hydrogen recovery system, respectively, is then investigated and compared. It is shown that the ejector stabilizes the hydrogen supply more quickly than the traditional mechanical system. As a result, it not only improves the hydrogen utilization rate and environmental safety of the PEMFC system, but also reduces the overall hydrogen consumption. The simulation results for the I-V performance of the PEMFC with the Venturi ejector are shown to be in good qualitative agreement with the experimental results. Overall, the numerical framework constructed in the present study provides a useful tool for exploring the effects of the ejector design parameters on the hydrogen recovery performance and determining the operating conditions which maximize the performance of the PEMFC system.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.