  • Evaluation of an automated ...
    Bauquier, Sebastien H.; Lai, Alan; Jiang, Jonathan L.; Sui, Yi; Cook, Mark J.

    Neuroscience Bulletin/Neuroscience bulletin, 10/2015, Letnik: 31, Številka: 5
    Journal Article

    The aim of this prospective blinded study was to evaluate an automated algorithm for spike-andwave discharge(SWD) detection applied to EEGs from genetic absence epilepsy rats from Strasbourg(GAERS).Five GAERS underwent four sessions of 20-min EEG recording.Each EEG was manually analyzed for SWDs longer than one second by two investigators and automatically using an algorithm developed in MATLAB(?).The sensitivity,specificity,positive predictive value(PPV),and negative predictive value(NPV) were calculated for the manual(reference) versus the automatic(test) methods.The results showed that the algorithm had specificity,sensitivity,PPV and NPV 〉94%,comparable to published methods that are based on analyzing EEG changes in the frequency domain.This provides a good alternative as a method designed to mimic human manual marking in the time domain.