  • Whole-Cerebrum distortion-f...
    Zhao, Chenyang; Shao, Xingfeng; Shou, Qinyang; Ma, Samantha J.; Gokyar, Sayim; Graf, Christina; Stollberger, Rudolf; Wang, Danny JJ

    NeuroImage (Orlando, Fla.), 08/2023, Letnik: 277
    Journal Article

    •Whole-cerebrum distortion-free 3D pCASL imaging at 7T using TFL readout.•New set of labeling parameters, OPTIM background suppression pulse, and accelerated 3D TFL readout.•Improved test-retest repeatability and reduced susceptibility artifacts compared to 3D GRASE pCASL.•Increased SNR compared to the same sequence at 3T and 2D simultaneous multislice (SMS) TFL pCASL at 7T. Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (Gave = 0.4 mT/m, Gratio = 14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R = 2 × 2) and centric ordering was developed, and the number of segments (Nseg) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8°) and Nseg (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2 × 2 × 4 mm3 resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR.