This work presents the feasibility of monitoring state of charge (SoC) and state of health (SoH) of lithium-ion pouch batteries with acousto-ultrasonic guided waves. The guided waves are propagated ...and sensed using low-profile, built-in piezoelectric disc transducers that can be retrofitted onto off-the-shelf batteries. Both experimental and analytical studies are performed to understand the relationship between guided waves generated in a pitch-catch mode and battery SoC/SoH. The preliminary experiments on representative pouch cells show that the changes in time of flight (ToF) and signal amplitude (SA) resulting from shifts in the guided wave signals correlate strongly with the electrochemical charge-discharge cycling and aging. An analytical acoustic model is developed to simulate the variations in electrode moduli and densities during cycling, which correctly validates the absolute values and range of experimental ToF. It is further illustrated via a statistical study that ToF and SA can be used in a prediction model to accurately estimate SoC/SoH. Additionally, by using multiple sensors in a network configuration on the same battery, a significantly more reliable and accurate SoC/SoH prediction is achieved. The indicative results from this study can be extended to develop a unified guided-wave-based framework for SoC/SoH monitoring of many lithium-ion battery applications.
Display omitted
•Guided waves precisely estimate a lithium-ion battery's state of charge and health.•A simple implementation involves low-profile, built-in piezoelectric transducers.•Time of flight and signal amplitude are indicative of state of charge and health.•Signals from multiple propagation paths simplify computation and enhance accuracy.•Analytical results relate acoustic signature with changes in modulus and density.
Non-vitamin K oral anticoagulants (NOACs) are commonly prescribed with other medications that share metabolic pathways that may increase major bleeding risk.
To assess the association between use of ...NOACs with and without concurrent medications and risk of major bleeding in patients with nonvalvular atrial fibrillation.
Retrospective cohort study using data from the Taiwan National Health Insurance database and including 91 330 patients with nonvalvular atrial fibrillation who received at least 1 NOAC prescription of dabigatran, rivaroxaban, or apixaban from January 1, 2012, through December 31, 2016, with final follow-up on December 31, 2016.
NOAC with or without concurrent use of atorvastatin; digoxin; verapamil; diltiazem; amiodarone; fluconazole; ketoconazole, itraconazole, voriconazole, or posaconazole; cyclosporine; erythromycin or clarithromycin; dronedarone; rifampin; or phenytoin.
Major bleeding, defined as hospitalization or emergency department visit with a primary diagnosis of intracranial hemorrhage or gastrointestinal, urogenital, or other bleeding. Adjusted incidence rate differences between person-quarters (exposure time for each person during each quarter of the calendar year) of NOAC with or without concurrent medications were estimated using Poisson regression and inverse probability of treatment weighting using the propensity score.
Among 91 330 patients with nonvalvular atrial fibrillation (mean age, 74.7 years SD, 10.8; men, 55.8%; NOAC exposure: dabigatran, 45 347 patients; rivaroxaban, 54 006 patients; and apixaban, 12 886 patients), 4770 major bleeding events occurred during 447 037 person-quarters with NOAC prescriptions. The most common medications co-prescribed with NOACs over all person-quarters were atorvastatin (27.6%), diltiazem (22.7%), digoxin (22.5%), and amiodarone (21.1%). Concurrent use of amiodarone, fluconazole, rifampin, and phenytoin with NOACs had a significant increase in adjusted incidence rates per 1000 person-years of major bleeding than NOACs alone: 38.09 for NOAC use alone vs 52.04 for amiodarone (difference, 13.94 99% CI, 9.76-18.13); 102.77 for NOAC use alone vs 241.92 for fluconazole (difference, 138.46 99% CI, 80.96-195.97); 65.66 for NOAC use alone vs 103.14 for rifampin (difference, 36.90 99% CI, 1.59-72.22); and 56.07 for NOAC use alone vs 108.52 for phenytoin (difference, 52.31 99% CI, 32.18-72.44; P < .01 for all comparisons). Compared with NOAC use alone, the adjusted incidence rate for major bleeding was significantly lower for concurrent use of atorvastatin, digoxin, and erythromycin or clarithromycin and was not significantly different for concurrent use of verapamil; diltiazem; cyclosporine; ketoconazole, itraconazole, voriconazole, or posaconazole; and dronedarone.
Among patients taking NOACs for nonvalvular atrial fibrillation, concurrent use of amiodarone, fluconazole, rifampin, and phenytoin compared with the use of NOACs alone, was associated with increased risk of major bleeding. Physicians prescribing NOAC medications should consider the potential risks associated with concomitant use of other drugs.
Background
Whether non–vitamin K antagonist oral anticoagulants (NOACs) are superior to warfarin among Asians with nonvalvular atrial fibrillation remains unclear.
Methods and Results
In this ...nationwide retrospective cohort study collected from Taiwan National Health Insurance Research Database, there were 5843, 20 079, 27 777, and 19 375 nonvalvular atrial fibrillation patients taking apixaban, dabigatran, rivaroxaban and warfarin, respectively, from June 1, 2012 to December 31, 2016. Propensity‐score weighting was used to balance covariates across study groups. Patients were followed until the first occurrence of any efficacy or safety outcome or the end date of study. Hazard ratios (95% confidence intervals) comparing apixaban, dabigatran, and rivaroxaban with warfarin were: ischemic stroke/systemic embolism (IS/SE), 0.55 (0.43–0.69), 0.82 (0.68–0.98), and 0.81 (0.67–0.97); major bleeding, 0.41 (0.31–0.53), 0.65 (0.53–0.80), and 0.58 (0.46–0.72); and all‐cause mortality, 0.58 (0.51–0.66), 0.61 (0.54–0.68), and 0.57 (0.51–0.65). A total of 3623 (62%), 17 760 (88%), and 26 000 (94%) patients were taking low‐dose apixaban (2.5 mg twice daily), dabigatran (110 mg twice daily), and rivaroxaban (10–15 mg once daily), respectively. Similar to all‐dose NOACs, all low‐dose NOACs had lower risk of IS/SE, major bleeding, and mortality when compared with warfarin. In contrast to other standard‐dose NOACs, apixaban was associated with lower risks of IS/SE (0.45 0.31–0.65), major bleeding (0.29 0.18–0.46), and mortality (0.23 0.17–0.31) than warfarin.
Conclusions
All NOACs were associated with lower risk of IS/SE, major bleeding, and mortality compared with warfarin in the largest real‐world practice among Asians with nonvalvular atrial fibrillation. All low‐dose NOACs had lower risk of IS/SE, major bleeding, and mortality when compared with warfarin. Standard‐dose apixaban caused a lower risk of IS/SE, major bleeding, and mortality compared with warfarin.
Abstract
Dual-energy X-ray absorptiometry (DXA) is underutilized to measure bone mineral density (BMD) and evaluate fracture risk. We present an automated tool to identify fractures, predict BMD, and ...evaluate fracture risk using plain radiographs. The tool performance is evaluated on 5164 and 18175 patients with pelvis/lumbar spine radiographs and Hologic DXA. The model is well calibrated with minimal bias in the hip (slope = 0.982, calibration-in-the-large = −0.003) and the lumbar spine BMD (slope = 0.978, calibration-in-the-large = 0.003). The area under the precision-recall curve and accuracy are 0.89 and 91.7% for hip osteoporosis, 0.89 and 86.2% for spine osteoporosis, 0.83 and 95.0% for high 10-year major fracture risk, and 0.96 and 90.0% for high hip fracture risk. The tool classifies 5206 (84.8%) patients with 95% positive or negative predictive value for osteoporosis, compared to 3008 DXA conducted at the same study period. This automated tool may help identify high-risk patients for osteoporosis.
To describe trends in the epidemiology of gout and patterns of urate-lowering treatment (ULT) in the UK general population from 1997 to 2012.
We used the Clinical Practice Research Datalink to ...estimate the prevalence and incidence of gout for each calendar year from 1997 to 2012. We also investigated the pattern of gout management for both prevalent and incident gout patients.
In 2012, the prevalence of gout was 2.49% (95% CI 2.48% to 2.51%) and the incidence was 1.77 (95% CI 1.73 to 1.81) per 1000 person-years. Prevalence and incidence both were significantly higher in 2012 than in 1997, with a 63.9% increase in prevalence and 29.6% increase in incidence over this period. Regions with highest prevalence and incidence were the North East and Wales. Among prevalent gout patients in 2012, only 48.48% (95% CI 48.08% to 48.89%) were being consulted specifically for gout or treated with ULT and of these 37.63% (95% CI 37.28% to 38.99%) received ULT. In addition, only 18.6% (95% CI 17.6% to 19.6%) of incident gout patients received ULT within 6 months and 27.3% (95% CI 26.1% to 28.5%) within 12 months of diagnosis. The management of prevalent and incident gout patients remained essentially the same during the study period, although the percentage of adherent patients improved from 28.28% (95% CI 27.33% to 29.26%) in 1997 to 39.66% (95% CI 39.11% to 40.22%) in 2012.
In recent years, both the prevalence and incidence of gout have increased significantly in the UK. Suboptimal use of ULT has not changed between 1997 and 2012. Patient adherence has improved during the study period, but it remains poor.
This work proposes and analyzes a structurally-integrated lithium-ion battery concept. The multifunctional energy storage composite (MESC) structures developed here encapsulate lithium-ion battery ...materials inside high-strength carbon-fiber composites and use interlocking polymer rivets to stabilize the electrode layer stack mechanically. These rivets enable load transfer between battery layers, allowing them to store electrical energy while also contributing to the structural load carrying performance, without any modifications to the battery chemistry. The design rationale, fabrication processes, and experimental mechano-electrical characterization of first-generation MESCs are discussed. Experimental results indicate that the MESCs offer electrochemical performance comparable to standard lithium-ion cells, despite the disruptive design change. The mechanical performance of MESCs is assessed via quasi-static three-point bending tests, with results showing significantly improved mechanical stiffness and strength over traditional pouch cells. The rivets minimize interlayer shear movement of the electrode stack, thus allowing it to maintain electrochemical functionalities while carrying mechanical bending. While minimal load application can cause permanent deformation of pouch cells, MESCs maintain their structural integrity and energy-storage capabilities under realistic repeated loading. The results obtained demonstrate the mechanical robustness of MESCs, which allow them to be fabricated as energy-storing structures for electric vehicles and other applications.
Display omitted
•Multifunctional energy storage composites (MESC) embed battery layers in structures.•Interlocking rivets anchor battery layers which contribute to mechanical performance.•Experimental testing of MESC shows comparable electrochemical behavior to baseline.•At 60% packing efficiency, MESC gain 15× mechanical rigidity compared to pouch cells.•MESC show negligible capacity fading after 1000 bending cycles at 80% design load.
Gout is a crystal-deposition disease that results from chronic elevation of uric acid levels above the saturation point for monosodium urate (MSU) crystal formation. Initial presentation is mainly ...severely painful episodes of peripheral joint synovitis (acute self-limiting 'attacks') but joint damage and deformity, chronic usage-related pain and subcutaneous tophus deposition can eventually develop. The global burden of gout is substantial and seems to be increasing in many parts of the world over the past 50 years. However, methodological differences impair the comparison of gout epidemiology between countries. In this comprehensive Review, data from epidemiological studies from diverse regions of the world are synthesized to depict the geographic variation in gout prevalence and incidence. Key advances in the understanding of factors associated with increased risk of gout are also summarized. The collected data indicate that the distribution of gout is uneven across the globe, with prevalence being highest in Pacific countries. Developed countries tend to have a higher burden of gout than developing countries, and seem to have increasing prevalence and incidence of the disease. Some ethnic groups are particularly susceptible to gout, supporting the importance of genetic predisposition. Socioeconomic and dietary factors, as well as comorbidities and medications that can influence uric acid levels and/or facilitate MSU crystal formation, are also important in determining the risk of developing clinically evident gout.
Background Liver cirrhotic patients with nonvalvular atrial fibrillation have been excluded from randomized clinical studies regarding oral anticoagulants for stroke prevention. Whether non-vitamin K ...antagonist oral anticoagulants ( NOAC s) are superior to warfarin for these patients remains unclear. Methods and Results This nationwide retrospective cohort study, with data collected from the Taiwan National Health Insurance Research Database, enrolled 2428 liver cirrhotic patients with nonvalvular atrial fibrillation taking apixaban (n=171), dabigatran (n=535), rivaroxaban (n=732), or warfarin (n=990) from June 1, 2012, to December 31, 2016. We used propensity score-based stabilized weights to balance covariates across study groups. Patients were followed until the occurrence of an event or the end date of study. The NOAC group (n=1438) showed risk of ischemic stroke/systemic embolism and intracranial hemorrhage comparable to that of the warfarin group (n=990) after adjustment. The NOAC group showed significantly lower risk of gastrointestinal bleeding (hazard ratio: 0.51 95% CI, 0.32-0.79; P=0.0030) and all major bleeding (hazard ratio: 0.51 95% CI, 0.32-0.74; P=0.0003) compared with warfarin group. Overall, 90% (n=1290) of patients were taking a low-dose NOAC (apixaban 2.5 mg twice daily, rivaroxaban 10-15 mg daily, or dabigatran 110 mg twice daily). The subgroup analysis indicated that both dabigatran and rivaroxaban showed lower risk of all major bleeding than warfarin. The advantage of lower gastrointestinal and all major bleeding with NOACs over warfarin is contributed by those subgroups with either nonalcoholic or nonadvanced liver cirrhosis. Conclusions NOACs have a risk of thromboembolism comparable to that of warfarin and a lower risk of major bleeding among liver cirrhotic Asian patients with nonvalvular atrial fibrillation. Consequently, thromboprophylaxis with low-dose NOAC s may be considered for such patients.
An investigation was conducted to develop an effective automated tool to deploy micro-fabricated stretchable networks of distributed sensors onto the surface of large structures at macroscale to ...create “smart” structures with embedded distributed sensor networks. Integrating a large network of distributed sensors with structures has been a major challenge in the design of so-called smart structures or devices for cyber-physical applications where a large amount of usage data from structures or devices can be generated for artificial intelligence applications. Indeed, many “island-and-serpentine”-type distributed sensor networks, while promising, remain difficult to deploy. This study aims to enable such networks to be deployed in a safe, automated, and efficient way. To this end, a scissor-hinge controlled system was proposed as the basis for a deployment mechanism for such stretchable sensor networks (SSNs). A model based on a kinematic scissor-hinge mechanism was developed to simulate and design the proposed system to automatically stretch a micro-scaled square network with uniformly distributed sensor nodes. A prototype of an automatic scissor-hinge stretchable tool was constructed during the study with an array of four scissor-hinge mechanisms, each belt-driven by a single stepper motor. Two micro-fabricated SSNs from a 100 mm wafer were fabricated at the Stanford Nanofabrication Facility for this deployment study. The networks were designed to be able to cover an area 100 times their manufacturing size (from a 100 mm diameter wafer to a 1 m2 active area) once stretched. It was demonstrated that the proposed deployment tool could place sensor nodes in prescribed locations efficiently within a drastically shorter time than in current labor-intensive manual deployment methods.