Hand washing and maintaining social distance are the main measures recommended by the World Health Organization (WHO) to avoid contracting COVID-19. Unfortunately, these measured do not prevent ...infection by inhalation of small droplets exhaled by an infected person that can travel distance of meters or tens of meters in the air and carry their viral content. Science explains the mechanisms of such transport and there is evidence that this is a significant route of infection in indoor environments. Despite this, no countries or authorities consider airborne spread of COVID-19 in their regulations to prevent infections transmission indoors. It is therefore extremely important, that the national authorities acknowledge the reality that the virus spreads through air, and recommend that adequate control measures be implemented to prevent further spread of the SARS-CoV-2 virus, in particularly removal of the virus-laden droplets from indoor air by ventilation.
Although it is recognized that ozone causes acute and chronic health effects and that even trace amounts of ozone are potentially deleterious to human health, information about global and local ...exposures to ozone in different indoor environments is limited. To synthesize the existing knowledge, this review analyzes the magnitude of and the trends in global and local exposure to ozone in schools and offices and the factors controlling the exposures.
In conducting the literature review, Web of Science, SCOPUS, Google Scholar, and PubMed were searched using 38 search terms and their combinations to identify manuscripts, reports, and directives published between 1973 and 2018. The search was then extended to the reference lists of relevant articles.
The calculated median concentration of ozone both in school (8.50 μg/m3) and office (9.04 μg/m3) settings was well below the WHO guideline value of 100 μg/m3 as a maximum 8 h mean concentration. However, a large range of average concentrations of ozone was reported, from 0.8–114 μg/m3 and from 0 to 96.8 μg/m3 for school and office environments, respectively, indicating situations where the WHO values are exceeded. Outdoor ozone penetrating into the indoor environment is the main source of indoor ozone, with median I/O ratios of 0.21 and 0.29 in school and office environments, respectively. The absence of major indoor ozone sources and ozone sinks, including gas-phase reactions and deposition, are the reasons for lower indoor than outdoor ozone concentrations. However, there are indoor sources of ozone that are of significance in certain indoor environments, including printers, photocopiers, and many other devices and appliances designed for indoor use (e.g., air cleaners), that release ozone either intentionally or unintentionally. Due to significantly elevated outdoor ozone concentrations during summer, summer indoor concentrations are typically elevated. In addition, the age of a building and various housing aspects (carpeting, air conditioning, window fans, and window openings) have been significantly associated with indoor ozone levels.
The existing means for reducing ozone and ozone reaction products in school and office settings are as follows: 1) reduce penetration of outdoor ozone indoors by filtering ozone from the supply air; 2) limit the use of printers, photocopiers, and other devices and appliances that emit ozone indoors; 3) limit gas-phase reactions by limiting the use of materials and products (e.g. cleaning chemicals) the emissions of which react with ozone.
•The potential for ozone formation in the troposphere is increasing.•Ozone is of particular significance in schools and offices.•The median indoor concentration of O3 was 8.50 μg/m3 and 9.04 μg/m3 in schools and offices, respectively.•Median I/O ratios of O3 were 0.21 and 0.29 in schools and offices, respectively.•The concentrations of ozone and ozone reaction products must be minimized.
Although nitrogen dioxide (NO2) is one of the most common air pollutants encountered indoors, and extensive literature has examined the link between NO2 exposure and duration causing adverse ...respiratory effects in susceptible populations, information about global and local exposure to NO2 in different indoor environments is limited. To synthesize the existing knowledge, this review analyzes the magnitude of and the trends in global and local exposure to NO2 in schools and offices, and the factors that control exposure.
For the literature review, Web of Science, SCOPUS, Google Scholar, and PubMed were searched using 42 search terms and their combinations to identify manuscripts, reports, and directives published between 1971 and 2019. The search was then extended to the reference lists of relevant articles.
The calculated median, as well as the mean, concentration of NO2 in school (median 21.1 μg/m3; mean 29.4 μg/m3) and office settings (median 22.7 μg/m3; mean 25.1 μg/m3) was well below the World Health Organization (WHO) guideline of 40 μg/m3 for the annual mean NO2 concentration. However, a large range of average concentrations of NO2 were reported, from 6.00 to 68.5 μg/m3 and from 3.40 to 56.5 μg/m3 for school and office environments, respectively, indicating situations where the WHO guidelines are exceeded. Outdoor levels of NO2 are a reliable predictor of indoor NO2 levels across seasons, with mean and median Indoor/Outdoor (I/O) ratios of 0.9 and 0.7 in school and 0.9 and 0.8 in office environments, respectively. The absence of major indoor NO2 emission sources and NO2 sinks, including chemical reactions and deposition, are the reasons for lower indoor NO2 concentrations. During the winter, outdoor NO2 concentrations are generally higher than during the summer. In addition, various building and indoor environment characteristics, such as type of ventilation, air exchange rates, airtightness of the envelope, furnishing and surface characteristics of the building, location of the building (urban versus suburban and proximity to traffic routes), as well as occupants' behavior (such as opening windows), have been statistically significantly associated with indoor NO2 levels in school and office environments.
Indoor exposure to NO2 from the infiltration of ambient air can be significant in urban areas, and in the case of high traffic volume. Although reducing transportation emissions is challenging, there are several easier means to reduce indoor NO2 concentrations, including a ventilation strategy with suitable filters; location planning of new schools, classrooms, and ventilating windows or intakes; traffic planning (location and density); and reducing the use of NO2-releasing indoor sources.
•The level of NO2 in ambient air is strongly related to the population and traffic density.•NO2 is a health risk in outdoor and indoor air, and must be minimized.•The median indoor concentration of NO2 was 26.1 μg/m3 and 22.7 μg/m3 in schools and offices, respectively.•The median Indoor/Outdoor (I/O) NO2 ratio was 0.7 and 0.8 in schools and offices, respectively.•The mean NO2 concentration in schools and offices is statistically significantly higher in Oceania and Asia than in Europe.
Summary Background Exposure to ambient air pollution increases morbidity and mortality, and is a leading contributor to global disease burden. We explored spatial and temporal trends in mortality and ...burden of disease attributable to ambient air pollution from 1990 to 2015 at global, regional, and country levels. Methods We estimated global population-weighted mean concentrations of particle mass with aerodynamic diameter less than 2·5 μm (PM2·5 ) and ozone at an approximate 11 km × 11 km resolution with satellite-based estimates, chemical transport models, and ground-level measurements. Using integrated exposure–response functions for each cause of death, we estimated the relative risk of mortality from ischaemic heart disease, cerebrovascular disease, chronic obstructive pulmonary disease, lung cancer, and lower respiratory infections from epidemiological studies using non-linear exposure–response functions spanning the global range of exposure. Findings Ambient PM2·5 was the fifth-ranking mortality risk factor in 2015. Exposure to PM2·5 caused 4·2 million (95% uncertainty interval UI 3·7 million to 4·8 million) deaths and 103·1 million (90·8 million 115·1 million) disability-adjusted life-years (DALYs) in 2015, representing 7·6% of total global deaths and 4·2% of global DALYs, 59% of these in east and south Asia. Deaths attributable to ambient PM2·5 increased from 3·5 million (95% UI 3·0 million to 4·0 million) in 1990 to 4·2 million (3·7 million to 4·8 million) in 2015. Exposure to ozone caused an additional 254 000 (95% UI 97 000–422 000) deaths and a loss of 4·1 million (1·6 million to 6·8 million) DALYs from chronic obstructive pulmonary disease in 2015. Interpretation Ambient air pollution contributed substantially to the global burden of disease in 2015, which increased over the past 25 years, due to population ageing, changes in non-communicable disease rates, and increasing air pollution in low-income and middle-income countries. Modest reductions in burden will occur in the most polluted countries unless PM2·5 values are decreased substantially, but there is potential for substantial health benefits from exposure reduction. Funding Bill & Melinda Gates Foundation and Health Effects Institute.
Display omitted
•Performance of in-car sensors was evaluated under lab/dynamic environments.•Driving with WO significantly contributes to daily traffic exposure in the morning hours.•WC-RC ...substantially reduced exposure to PM2.5/PNC but rapidly elevated CO2 level.•Probability of COVID-19 transmission dramatically increased with time in WC-RC.•Fresh air and efficient facemasks substantially reduced COVID-19 infection probability.
We examined the trade-offs between in-car aerosol concentrations, ventilation and respiratory infection transmission under three ventilation settings: windows open (WO); windows closed with air-conditioning on ambient air mode (WC-AA); and windows closed with air-conditioning on recirculation (WC-RC). Forty-five runs, covering a total of 324 km distance on a 7.2-km looped route, were carried out three times a day (morning, afternoon, evening) to monitor aerosols (PM2.5; particulate matter < 2.5 μm and PNC; particle number concentration), CO2 and environmental conditions (temperature and relative humidity). Ideally, higher ventilation rates would give lower in-car pollutant concentrations due to dilution from outdoor air. However, in-car aerosol concentrations increased with ventilation (WO > WC-AA > WC-RC) due to the ingress of polluted outdoor air on urban routes. A clear trade-off, therefore, exists for the in-car air quality (icAQ) versus ventilation; for example, WC-RC showed the least aerosol concentrations (i.e. four-times lower compared with WO), but corresponded to elevated CO2 levels (i.e. five-times higher compared with WO) in 20 mins. We considered COVID-19 as an example of respiratory infection transmission. The probability of its transmission from an infected occupant in a five-seater car was estimated during different quanta generation rates (2–60.5 quanta hr-1) using the Wells-Riley model. In WO, the probability with 50%-efficient and without facemasks under normal speaking (9.4 quanta hr-1) varied only by upto 0.5%. It increased by 2-fold in WC-AA (<1.1%) and 10-fold in WC-RC (<5.2%) during a 20 mins trip. Therefore, a wise selection of ventilation settings is needed to balance in-car exposure in urban areas affected by outdoor air pollution and that by COVID-19 transmission. We also successfully developed and assessed the feasibility of using sensor units in static and dynamic environments to monitor icAQ and potentially infer COVID-19 transmission. Further research is required to develop automatic-alarm systems to help reduce both pollutant exposure and infection from respiratory COVID-19 transmission.
Ever growing populations in cities are associated with a major increase in road vehicles and air pollution. The overall high levels of urban air pollution have been shown to be of a significant risk ...to city dwellers. However, the impacts of very high but temporally and spatially restricted pollution, and thus exposure, are still poorly understood. Conventional approaches to air quality monitoring are based on networks of static and sparse measurement stations. However, these are prohibitively expensive to capture tempo-spatial heterogeneity and identify pollution hotspots, which is required for the development of robust real-time strategies for exposure control. Current progress in developing low-cost micro-scale sensing technology is radically changing the conventional approach to allow real-time information in a capillary form. But the question remains whether there is value in the less accurate data they generate. This article illustrates the drivers behind current rises in the use of low-cost sensors for air pollution management in cities, while addressing the major challenges for their effective implementation.
Display omitted
•Impacts on the health of city dwellers due to high air pollution exposure are unknown.•Conventional sparse monitoring stations are unable to identify pollution hotspots.•Low-cost micro-scale sensing allows capturing real-time high-grained pollution data.•Fundamental drivers behind the rise of low-cost sensing and challenges are discussed.
Display omitted
•Predictive estimation approach improves airborne infection risk assessment methods.•SARS-CoV-2 estimated to be nearly as contagious as Mycobacterium tuberculosis.•SARS-CoV-2 much ...more transmissible through indoor air than seasonal influenza.•Current ventilation standards in public buildings are unlikely to control SARS-CoV-2.
The infectious emission rate is a fundamental input parameter for airborne transmission risk assessment, but data are limited due to reliance on estimates from chance superspreading events. This study assesses the strength of a predictive estimation approach developed by the authors for SARS-CoV-2 and uses novel estimates to compare the contagiousness of respiratory pathogens. We applied the approach to SARS-CoV-1, SARS-CoV-2, MERS, measles virus, adenovirus, rhinovirus, coxsackievirus, seasonal influenza virus and Mycobacterium tuberculosis (TB) and compared quanta emission rate (ERq) estimates to literature values. We calculated infection risk in a prototypical classroom and barracks to assess the relative ability of ventilation to mitigate airborne transmission. Our median standing and speaking ERq estimate for SARS-CoV-2 (2.7 quanta h−1) is similar to active, untreated TB (3.1 quanta h−1), higher than seasonal influenza (0.17 quanta h−1), and lower than measles virus (15 quanta h−1). We calculated event reproduction numbers above 1 for SARS-CoV-2, measles virus, and untreated TB in both the classroom and barracks for an activity level of standing and speaking at low, medium and high ventilation rates of 2.3, 6.6 and 14 L per second per person (L s–1 p–1), respectively. Our predictive ERq estimates are consistent with the range of values reported over decades of research. In congregate settings, current ventilation standards are unlikely to control the spread of viruses with upper quartile ERq values above 10 quanta h−1, such as SARS-CoV-2, indicating the need for additional control measures.
Display omitted
•Various green infrastructure (GI) options for air pollution mitigation were reviewed.•Methods for measuring air pollution reduction by GI were assessed and compared.•Green walls, ...green screens and green roofs are viable options in street canyons.•PM capture differs between plants mainly due to macro- and micromorphological traits.•Leaf washing is less effective than microscopy techniques for quantifying deposition.
Street canyons are generally highly polluted urban environments due to high traffic emissions and impeded dispersion. Green infrastructure (GI) is one potential passive control system for air pollution in street canyons, yet optimum GI design is currently unclear. This review consolidates findings from previous research on GI in street canyons and assesses the suitability of different GI forms in terms of local air quality improvement. Studies on the effects of various GI options (trees, hedges, green walls, green screens and green roofs) are critically evaluated, findings are synthesised, and possible recommendations are summarised. In addition, various measurement methods used for quantifying the effectiveness of street greening for air pollution reduction are analysed. Finally, we explore the findings of studies that have compared plant species for pollution mitigation. We conclude that the influences of different GI options on air quality in street canyons depend on street canyon geometry, meteorological conditions and vegetation characteristics. Green walls, green screens and green roofs are potentially viable GI options in existing street canyons, where there is typically a lack of available planting space. Particle deposition to leaves is usually quantified by leaf washing experiments or by microscopy imaging techniques, the latter of which indicates size distribution and is more accurate. The pollutant reduction capacity of a plant species largely depends on its macromorphology in relation to the physical environment. Certain micromorphological leaf traits also positively correlate with deposition, including grooves, ridges, trichomes, stomatal density and epicuticular wax amount. The complexity of street canyon environments and the limited number of previous studies on novel forms of GI in street canyons mean that offering specific recommendations is currently unfeasible. This review highlights a need for further research, particularly on green walls and green screens, to substantiate their efficacy and investigate technical considerations.
While low-cost particle sensors are increasingly being used in numerous applications, most of them have no heater or dryer at the inlet to remove water from the sample before measurement. ...Deliquescent growth of particles and the formation of fog droplets in the atmosphere can lead to significant increases in particle number concentration (PNC) and mass concentrations reported by such sensors. We carried out a detailed study using a Plantower PMS1003 low-cost particle sensor, both in the laboratory and under actual ambient field conditions, to investigate its response to increasing humidity and the presence of fog in the air. We found significant increases in particle number and mass concentrations at relative humidity above about 75 %. During a period of fog, the total PNC increased by 28 %, while the PNC larger than 2.5 µm increased by over 50 %. The PM10 concentration reported by the PMS1003 was 46 % greater than that on the standard monitor with a charcoal dryer at the inlet. While there is a causal link between particle pollution and adverse health effects, the presence of water on the particles is not harmful to humans. Therefore, air quality standards for particles are specifically limited to solid particles and standard particle monitoring instruments are fitted with a heater or dryer at the inlet to remove all liquid material from the sample before the concentrations are measured. This study shows that it is important to understand that the results provided by low-cost particle sensors, such as the PMS1003, cannot be used to ascertain if air quality standards are being met.
Air quality data collection near pollution sources is difficult, particularly when sites are complex, have physical barriers, or are themselves moving. Small Unmanned Aerial Vehicles (UAVs) offer new ...approaches to air pollution and atmospheric studies. However, there are a number of critical design decisions which need to be made to enable representative data collection, in particular the location of the air sampler or air sensor intake. The aim of this research was to establish the best mounting point for four gas sensors and a Particle Number Concentration (PNC) monitor, onboard a hexacopter, so to develop a UAV system capable of measuring point source emissions. The research included two different tests: (1) evaluate the air flow behavior of a hexacopter, its downwash and upwash effect, by measuring air speed along three axes to determine the location where the sensors should be mounted; (2) evaluate the use of gas sensors for CO₂, CO, NO₂ and NO, and the PNC monitor (DISCmini) to assess the efficiency and performance of the UAV based system by measuring emissions from a diesel engine. The air speed behavior map produced by test 1 shows the best mounting point for the sensors to be alongside the UAV. This position is less affected by the propeller downwash effect. Test 2 results demonstrated that the UAV propellers cause a dispersion effect shown by the decrease of gas and PN concentration measured in real time. A Linear Regression model was used to estimate how the sensor position, relative to the UAV center, affects pollutant concentration measurements when the propellers are turned on. This research establishes guidelines on how to develop a UAV system to measure point source emissions. Such research should be undertaken before any UAV system is developed for real world data collection.