Groin pain and functional limitations may occur after total hip arthroplasty (THA) due to iliopsoas impingement (IPI). We aimed to determine the risk factors and thresholds of cup protrusion for ...symptomatic IPI.
This retrospective case-control study evaluated 569 primary THAs performed by a single surgeon in a single center. In all THAs, the cup was inserted with the assistance of the computed tomography–based navigation system. Twenty-two THAs (3.9%) were identified to have symptoms of IPI and included in the IPI group. Control group 1 comprised 547 THAs. Control group 2 (66 THAs) was formed by recruiting 3 data-matched controls per patient in control group 1. Risk factors for IPI were assessed in the IPI group and control group 1. Further analysis was performed in the IPI group and control group 2 to evaluate cup protrusion parameters measured on computed tomography images and radiographs.
Multivariate logistic regression analysis confirmed that the anterolateral approach was associated with a higher risk of IPI (odds ratio OR, 4.20); however, its goodness of fit was low. Axial protrusion length ≥12 mm (OR, 23.29; sensitivity = 72.7; specificity = 91.0) and sagittal protrusion length ≥4 mm (OR, 61.60; sensitivity = 86.4; specificity = 78.8) were determined as independent predictors of symptomatic IPI. In the linear regression analyses, higher native acetabular version and lower cup anteversion and inclination were related to cup protrusion.
This study determined the thresholds of cup protrusion length for IPI and identified associated factors increasing cup protrusion, which are useful for surgeons in determining cup position and alignment.
We developed iodine-coated titanium implants to suppress microbial activity and prevent periprosthetic joint infection (PJI); their efficacy was demonstrated in animal and in vitro models. The iodine ...content in iodine-coated implants naturally decreases in vivo. However, to our knowledge, the effect of reduced iodine content on the implant's antimicrobial activity has not been evaluated to date.
(1) How much does the iodine content on the implant surface decrease after 4 and 8 weeks in vivo in a rat model? (2) What effect does the reduced iodine content have on the antimicrobial effect of the implant against multiple bacteria in an in vitro model?
This experiment was performed in two parts: an in vivo experiment to determine attenuation of iodine levels over time in rats, and an in vitro experiment in which we sought to assess whether the reduced iodine content observed in the in vivo experiment was still sufficient to deliver antimicrobial activity against common pathogens seen in PJI. For the in vivo experiment, three types of titanium alloy washers were implanted in rats: untreated (Ti), surface-anodized to produce an oxide film (Ti-O), and with an iodine layer on the oxidation film (Ti-I). The attenuation of iodine levels in rats was measured over time using inductively coupled plasma-mass spectrometry. Herein, only the Ti-I washer was used, with five implanted in each rat that were removed after 4 or 8 weeks. For the 4- and 8-week models, two rats and 15 washers were used. For the in vitro study, to determine the antibacterial effect, three types of washers (Ti, Ti-O, and Ti-I) (nine washers in total) were implanted in each rat. Then, the washers were removed and the antibacterial effect of each washer was examined on multiple bacterial species using the spread plate method and fluorescence microscopy. For the spread plate method, six rats were used, and five rats were used for the observation using fluorescence microscopy; further, 4- and 8-week models were made for each method. Thus, a total of 22 rats and 198 washers were used. Live and dead bacteria in the biofilm were stained, and the biofilm coverage percentage for quantitative analysis was determined using fluorescence microscopy in a nonblinded manner. Ti-I was used as the experimental group, and Ti and Ti-O were used as control groups. The total number of rats and washers used throughout this study was 24 and 213, respectively.
Iodine content in rats implanted with Ti-I samples decreased to 72% and 65% after the in vivo period of 4 and 8 weeks, respectively (p = 0.001 and p < 0.001, respectively). In the in vitro experiment, the Ti-I implants demonstrated a stronger antimicrobial activity than Ti and Ti-O implants in the 4- and 8-week models. Both the median number of bacterial colonies and the median biofilm coverage percentage with live bacteria on Ti-I were lower than those on Ti or Ti-O implants for each bacterial species in the 4- and 8-week models. There was no difference in the median biofilm coverage percentage of dead bacteria. In the 8-week model, the antibacterial activity using the spread plate method had median (interquartile range) numbers of bacteria on the Ti, Ti-O, and Ti-I implants of 112 (104 to 165) × 105, 147 (111 to 162) × 105, and 55 (37 to 67) × 105 of methicillin-sensitive Staphylococcus aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.009); 71 (39 to 111) × 105, 50 (44 to 62) × 105, and 26 (9 to 31)× 105 CFU of methicillin-resistant S. aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.034); and 77 (74 to 83) × 106, 111 (95 to 117) × 106, and 30 (21 to 45) × 106 CFU of Pseudomonas aeruginosa (Ti-I versus Ti, p = 0.004; Ti-I versus Ti-O, p = 0.009). Despite the decrease in the iodine content of Ti-I after 8 weeks, it demonstrated better antibacterial activity against all tested bacteria than the Ti and Ti-O implants.
Iodine-coated implants retained their iodine content and antibacterial activity against methicillin-sensitive S. aureus, methicillin-resistant S. aureus, and P. aeruginosa for 8 weeks in vivo in rats. To evaluate the longer-lasting antibacterial efficacy, further research using larger infected animal PJI models with implants in the joints of both males and females is desirable.
Iodine-coated titanium implants displayed an antibacterial activity for 8 weeks in rats in vivo. Although the findings in a rat model do not guarantee efficacy in humans, they represent an important step toward clinical application.
Abstract
Understanding the morphology of the superior aspect of the proximal femur is critical for treating femoral fracture. We assessed the correlation among the ideal insertion point of the ...femoral nail, femur head-neck axis, and native anteversion. One hundred patients with normal femurs were included in this study. Computed tomography (CT) images of the proximal femur superior aspect and amount of native anteversion were acquired. Generalised Procrustes analysis showed the morphological characteristics of the superior proximal femur according to native anteversion amount. Morphological characteristics were represented by 4 parameters; the correlation between parameters and native anteversion was investigated using CT data. The passing point of the line from the proximal femoral canal parallel to the native anteversion at the greater trochanter was located more posteriorly (mean 35.6%); the passing point of native anteversion was posterior in the femoral neck and head, although the line of the head-neck centre passed more anteriorly at the greater trochanter (mean 67.5%). This posterior translation was significantly associated with native anteversion amount. Morphometric geometric analysis showed that the lag screw could not pass head-neck centre from the nail inserted into proximal femoral canal. Anterior insertion of the nail was needed for positioning the lag screw centre.
This report seeks to clarify whether the dosage and duration of preoperative concurrent corticosteroid use influence postoperative complications after primary total joint arthroplasty (TJA).
This ...retrospective single institutional study enrolled 1128 primary TJA cases, including 905 total hip arthroplasties and 223 total knee arthroplasties at a minimum 6 months of follow-up. Mean follow-up period was 51.9 ± 34.1 months (range 6-146). Of all joints, 120 joints (10.6%) were associated with chronic concurrent oral corticosteroid use. Multivariate analysis was performed to identify whether chronic concurrent oral corticosteroid use elevated the risk of postoperative complications including surgical site infection/periprosthetic joint infection, delayed wound healing, periprosthetic fracture, and implant loosening. For chronic concurrent oral corticosteroid user, we determined whether the dosage and duration of preoperative concurrent corticosteroid use influenced postoperative complications and have an effective threshold for postoperative complications using receiver operating characteristic curve analysis.
The multivariate analysis revealed that American Society of Anesthesiologist Physical Status 3 was an independent risk factor for postoperative complications, while concurrent oral corticosteroid use was not an independent risk factor. When we compared joints with (n = 13) and without (n = 107) postoperative complications in chronic concurrent oral corticosteroid user, there was no statistical difference in the dosage (P = .97) and duration (P = .69) between the 2 groups. Area under the curve values for the oral corticosteroid dosages and duration were 0.482 and 0.549, respectively.
This study revealed that neither dosage nor duration of concurrent oral corticosteroid use was predictive of postoperative complications after TJA. American Society of Anesthesiologist Physical Status 3 is a major factor in postoperative complications after TJA.
We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measuring hip-knee-ankle (HKA) angle in patients with knee osteoarthritis, by comparing it with ...radiography. In this prospective study, we analysed 60 knees (30 patients) with knee osteoarthritis. We measured HKA angle using OpenPose and radiography before or after total knee arthroplasty and assessed the test-retest reliability of each method with intraclass correlation coefficient (1, 1). We evaluated the ability to estimate the radiographic measurement values from the OpenPose values using linear regression analysis and used intraclass correlation coefficients (2, 1) and Bland-Altman analyses to evaluate the agreement and error between OpenPose and radiographic measurements. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1, 1) = 1.000) and excellent agreement with radiography (intraclass correlation coefficient (2, 1) = 0.915), with regression analysis indicating a large correlation (R
= 0.865). OpenPose also had a 1.1° fixed error and no systematic error when compared with radiography. This is the first study to validate the use of OpenPose for the estimation of HKA angle in patients with knee osteoarthritis. OpenPose is a reliable and valid tool for measuring HKA angle in patients with knee osteoarthritis. OpenPose, which enables non-invasive and simple measurements, may be a useful tool to assess changes in HKA angle and monitor the progression and post-operative course of knee osteoarthritis. Furthermore, this validated tool can be used not only in clinics and hospitals, but also at home and in training gyms; thus, its use could potentially be expanded to include self-assessment/monitoring.
There have been no studies on the differences in impingement-free angle that result from different combined anteversion (CA) patterns. The aim of this study was to find the optimal CA pattern for ...achieving a favorable impingement-free angle, including bony and prosthetic impingement, in total hip arthroplasty.
We evaluated 100 patients with no hip arthritis. We investigated the impingement-free angle (flexion, internal rotation with 90° flexion, extension, and external rotation) after changing the stem and cup anteversions to satisfy several CA patterns cup anteversion + stem anteversion = 30°, 40°, 50°, and 60°; cup anteversion + 0.7 × stem anteversion = 37.3° (:Widmer's theory); and cup anteversion + 0.77 × stem anteversion = 43.3° (:Yoshimine's theory) using 3-dimensional templating software.
The impingement-free angle changed dramatically among the various CA patterns. The optimal CA was changed by various stem anteversion. Only CA: Widmer with stem anteversion of 20° satisfied daily-life range of motion (ROM) requirements (flexion ≥130°, internal rotation with 90° flexion ≥ 45°, extension ≥ 40°, external rotation ≥ 40°).
Good impingement-free angle cannot be obtained with single fixed CA. Different CA patterns should be used, depending on the differences in the stem anteversion. A CA of 30° with 0° ≤ stem anteversion ≤10°; a CA:Widmer with 20° of stem anteversion; a CA of 40° or Widmer with 30° of stem anteversion. When stem anteversion is ≥40°, CA should be decided by each patient's state. Among them, a stem anteversion of 20° with cup anteversion of 23.3° was found to be the best CA pattern.
Introduction
This report is the first study to compare the clinical outcomes between cementless and cemented femoral prostheses in total hip arthroplasty (THA) with subtrochanteric femoral shortening ...osteotomy for Crowe type IV hips.
Materials and methods
We identified 26 hips in 20 patients who had undergone cemented (
n
= 13) or cementless (
n
= 13) THA with subtrochanteric femoral shortening osteotomy for Crowe type IV hips with a minimum follow-up period of 2 years. The mean follow-up period was 60.8 ± 33.9 months (24–120 months). We compared radiological findings, postoperative clinical recoveries, postoperative complications, and implant survival rates.
Results
In both groups, there were no cases of aseptic loosening for the acetabular and femoral implant. In terms of bone union at the osteotomy site, the mean duration was significantly longer in the cemented group (9.8 ± 4.2 months) than in the cementless group (5.0 ± 1.9 months). The clinical hip score in gait and pain at 3 months postoperatively was significantly higher in the cemented group than in the cementless group, while there were no significant changes at other timepoints between two groups. The number of postoperative complications was not significantly different between the two groups. The implant survival rate was 92% in the cementless group and 100% in the cemented group at 5 years postoperatively (
P
= 0.31).
Conclusions
The cemented femoral prosthesis is superior to the cementless femoral prosthesis for early clinical recovery, while the duration required to achieve bone union at the osteotomy site is longer in the cemented femoral prostheses. It is possible for surgeons to perform successful hip reconstructions, regardless of the fixation method used for THA with shortening femoral osteotomy.
Periprosthetic joint infection (PJI) is characterized by biofilm infection, which is difficult to alleviate while preserving implant integrity. Furthermore, long-term antibiotic therapy may increase ...the prevalence of drug-resistant bacterial strains, necessitating a non-antibacterial approach. Adipose-derived stem cells (ADSCs) exert antibacterial effects; however, their efficacy in PJI remains unclear. This study investigates the efficacy of combined intravenous ADSCs and antibiotic therapy in comparison to antibiotic monotherapy in a methicillin-sensitive Staphylococcus aureus (MSSA)-infected PJI rat model. The rats were randomly assigned and equally divided into 3 groups: no-treatment group, antibiotic group, ADSCs with antibiotic group. The ADSCs with antibiotic group exhibited the fastest recovery from weight loss, with lower bacterial counts (p = 0.013 vs. no-treatment group; p = 0.024 vs. antibiotic group) and less bone density loss around the implants (p = 0.015 vs. no-treatment group; p = 0.025 vs. antibiotic group). The modified Rissing score was used to evaluate localized infection on postoperative day 14 and was the lowest in the ADSCs with antibiotic group; however, no significant difference was observed between the antibiotic group and ADSCs with antibiotic group (p < 0.001 vs. no-treatment group; p = 0.359 vs. antibiotic group). Histological analysis revealed a clear, thin, and continuous bony envelope, a homogeneous bone marrow, and a defined, normal interface in the ADSCs with antibiotic group. Moreover, the expression of cathelicidin expression was significantly higher (p = 0.002 vs. no-treatment group; p = 0.049 vs. antibiotic group), whereas that of tumor necrosis factor (TNF)-α and interleukin(IL)-6 was lower in the ADSCs with antibiotic group than in the no-treatment group (TNF-α, p = 0.010 vs. no-treatment group; IL-6, p = 0.010 vs. no-treatment group). Thus, the combined intravenous ADSCs and antibiotic therapy induced a stronger antibacterial effect than antibiotic monotherapy in a MSSA-infected PJI rat model. This strong antibacterial effect may be related to the increased cathelicidin expression and decreased inflammatory cytokine expression at the site of infection.
Subcutaneous adipose tissue represents an abundant source of multipotent adult stem cells named as Adipose-derived stem cells (ADSCs). With a cell sheet approach, ADSCs survive longer, and can be ...delivered in large quantities. We investigated whether intra-articular ADSC sheets attenuated osteoarthritis (OA) progression in a rabbit anterior cruciate ligament transection (ACLT) model.
Fabricating medium containing ascorbate-2-phosphate was used to enhance collagen protein secretion by the ADSCs to make ADSC sheets. At 4 weeks after ACLT, autologous ADSC sheets were injected intra-articularly into the right knee (ADSC sheets group), and autologous cell death sheets treated by liquid nitrogen were injected into the left knee (control group). Subsequent injections were administered once weekly. Femoral condyles were compared macroscopically and histologically.
Macroscopically, OA progression was significantly milder in the ADSC sheets than in the control groups. Histologically, control knees showed obvious erosions in the medial and lateral condyles, while cartilage was retained predominantly in the ADSC sheets group. Immunohistochemically, MMP-1, MMP-13, ADAMTS-4 were less expressive in the ADSC sheets than in the control groups.
Periodic ADSC sheets injections inhibited articular cartilage degeneration without inducing any adverse effects. A large quantity of autologous ADSCs delivered by cell sheets homed to the synovium and protected chondrocytes.
A few previous studies have investigated patient satisfaction after total hip arthroplasty (THA) according to the degree of pelvic deformity. This study compared patient-reported outcomes after ...primary THA for Crowe types III, IV and I dysplasia.
This retrospective, single-center, single-surgeon case-control study included patients who underwent primary THA between 2008 and 2016. We sent postal questionnaires to 38 patients with Crowe type III and IV dysplasia. Among the questionnaire respondents, 23 patients, excluding those with a follow-up period of < 1 year, were enrolled as the H group. The control group included 46 patients with Crowe type I, matched for sex, age, body mass index and surgical approach. To investigate the influence of femoral shortening osteotomy, the H group was divided according to whether femoral shortening osteotomy was performed. Ten patients underwent THA with femoral shortening osteotomy (FO group), while 12 patients underwent THA without femoral shortening osteotomy (N-FO group). Patient demographics, mean follow-up period, surgical information, pre- and postoperative leg length discrepancy (LLD), and perioperative complications were investigated. Clinical evaluations were performed using the Japanese Orthopaedic Association (JOA) scores, 36-item short-form survey (SF-36), net promotor score (NPS), visual analogue scale (VAS), and questionnaires. The VAS and SF-36 scores were determined only at final follow-up.
The H and control groups were not significantly different in the postoperative JOA scores and SF-36. In the H group, VAS at the final follow-up was significantly higher, and significantly more patients felt that postoperative rehabilitation was serious, expressing that they underwent THA for LLD correction. In addition, the VAS scores in the FO group was higher than those in the N-FO group. Postoperative LLD was significantly greater in the H group than in the control group. Each group had an NPS of > 50.
The postoperative VAS score was higher in Crowe type III and IV dysplasia than in Crowe type I dysplasia, but no significant differences were detected in the postoperative satisfaction, JOA score, and SF-36 score. These findings may help explain the effects of THA preoperatively to patients with Crowe type III and IV dysplasia.
Therapeutic Level 3b.