We explored the feasibility of collecting convalescent plasma for passive immunotherapy of Middle East respiratory syndrome coronavirus (MERS-CoV) infection by using ELISA to screen serum samples ...from 443 potential plasma donors: 196 patients with suspected or laboratory-confirmed MERS-CoV infection, 230 healthcare workers, and 17 household contacts exposed to MERS-CoV. ELISA-reactive samples were further tested by indirect fluorescent antibody and microneutralization assays. Of the 443 tested samples, 12 (2.7%) had a reactive ELISA result, and 9 of the 12 had reactive indirect fluorescent antibody and microneutralization assay titers. Undertaking clinical trials of convalescent plasma for passive immunotherapy of MERS-CoV infection may be feasible, but such trials would be challenging because of the small pool of potential donors with sufficiently high antibody titers. Alternative strategies to identify convalescent plasma donors with adequate antibody titers should be explored, including the sampling of serum from patients with more severe disease and sampling at earlier points during illness.
Phase 1 clinical trials with a DNA vaccine for dengue demonstrated that the vaccine is safe and well tolerated, however it produced less than optimal humoral immune responses. To determine if the ...immunogenicity of the tetravalent dengue DNA vaccine could be enhanced, we explored alternate, yet to be tested, methods of vaccine administration in non-human primates. Animals were vaccinated on days 0, 28 and 91 with either a low (1 mg) or high (5 mg) dose of vaccine by the intradermal or intramuscular route, using either needle-free injection or electroporation devices. Neutralizing antibody, IFN-γ T cell and memory B cell responses were compared to a high dose group vaccinated with a needle-free intramuscular injection delivery device similar to what had been used in previous preclinical and clinical studies. All previously untested vaccination methodologies elicited improved immune responses compared to the high dose needle-free intramuscular injection delivery group. The highest neutralizing antibody responses were observed in the group that was vaccinated with the high dose formulation via intradermal electroporation. The highest IFN-γ T cell responses were also observed in the high dose intradermal electroporation group and the CD8+ T cells were the dominant contributors for the IFNγ response. Memory B cells were detected for all four serotypes. More than a year after vaccination, groups were challenged with dengue-1 virus. Both the low and high dose intradermal electroporation groups had significantly fewer days of dengue-1 virus RNAemia compared to the control group. The results from this study demonstrate that using either an electroporation device and/or the intradermal route of delivery increases the immune response generated by this vaccine in non-human primates and should be explored in humans.
As of 13 November 2015, 1618 laboratory-confirmed human cases of Middle East respiratory syndrome coronavirus (MERS-CoV) infection, including 579 deaths, had been reported to the World Health ...Organization. No specific preventive or therapeutic agent of proven value against MERS-CoV is currently available. Public Health England and the International Severe Acute Respiratory and Emerging Infection Consortium identified passive immunotherapy with neutralizing antibodies as a treatment approach that warrants priority study. Two experimental MERS-CoV vaccines were used to vaccinate two groups of transchromosomic (Tc) bovines that were genetically modified to produce large quantities of fully human polyclonal immunoglobulin G (IgG) antibodies. Vaccination with a clade A γ-irradiated whole killed virion vaccine (Jordan strain) or a clade B spike protein nanoparticle vaccine (Al-Hasa strain) resulted in Tc bovine sera with high enzyme-linked immunosorbent assay (ELISA) and neutralizing antibody titers in vitro. Two purified Tc bovine human IgG immunoglobulins (Tc hIgG), SAB-300 (produced after Jordan strain vaccination) and SAB-301 (produced after Al-Hasa strain vaccination), also had high ELISA and neutralizing antibody titers without antibody-dependent enhancement in vitro. SAB-301 was selected for in vivo and preclinical studies. Administration of single doses of SAB-301 12 hours before or 24 and 48 hours after MERS-CoV infection (Erasmus Medical Center 2012 strain) of Ad5-hDPP4 receptor-transduced mice rapidly resulted in viral lung titers near or below the limit of detection. Tc bovines, combined with the ability to quickly produce Tc hIgG and develop in vitro assays and animal model(s), potentially offer a platform to rapidly produce a therapeutic to prevent and/or treat MERS-CoV infection and/or other emerging infectious diseases.
Abstract Candidate dengue DNA vaccine constructs for each dengue serotype were developed by incorporating pre-membrane and envelope genes into a plasmid vector. A Phase 1 clinical trial was performed ...using the dengue virus serotype-1 (DENV-1) vaccine construct (D1ME100 ). The study was an open-label, dose-escalation, safety and immunogenicity trial involving 22 healthy flavivirus-naïve adults assigned to one of two groups. Each group received three intramuscular injections (0, 1, and 5 months) of either a high dose (5.0 mg, n = 12) or a low dose (1.0 mg, n = 10) DNA vaccine using the needle-free Biojector® 2000. The most commonly reported solicited signs and symptoms were local mild pain or tenderness (10/22, 45%), local mild swelling (6/22, 27%), muscle pain (6/22, 27%) and fatigue (6/22, 27%). Five subjects (41.6%) in the high dose group and none in the low dose group developed detectable anti-dengue neutralizing antibodies. T-cell IFN gamma responses were detected in 50% (4/8) and 83.3% (10/12) of subjects in the low and high dose groups, respectively. The safety profile of the DENV-1 DNA vaccine is acceptable at both doses administered in the study. These results demonstrate a favorable reactogenicity and safety profile of the first in human evaluation of a DENV-1 DNA vaccine.
The hemagglutination-inhibition (HAI) assay is a critical component for measurement of immunogenicity in influenza vaccine development. It is unknown if the results can be influenced by sample type ...and anticoagulants. The purpose of this study was to evaluate the influence of different sample collection methods, in particular different anticoagulants, and choice of plasma or serum, on influenza virus serological assays.
Blood samples from thirty donors previously immunized against influenza viruses were collected using six different types of blood collection tubes, two of which collect serum and four of which contain various anticoagulants for collecting plasma. Serum: (1) serum separator tubes (SST); and (2) Plus Plastic serum "red-top serum" tubes. Plasma: (3) spray-coated K2 ethylenediaminetetraacetic acid (EDTA) tubes: (4) Sodium Heparin tubes; (5) Citrate tubes with 3.2% sodium citrate solution; and (6) Glass Blood Collection tubes with acid citrate dextrose. Samples were tested against three different influenza viruses (A/California/07/2009 (H1N1pdm09), A/Texas/50/2012 (H3N2), and B/Massachusetts/2/2012) for hemagglutination inhibition titer and virus neutralization titer via a microneutralization (MN) assay, and data compared to that obtained for standard serum sample collected in SST.
HAI and MN titers against type A viruses were within two dilutions compared to SST collection method over 96% of the time irrespective of sample type or anticoagulant. However, HAI titers for type B virus were more variable across different collection methods. EDTA plasma samples were greater than two dilutions higher than SST serum samples 70% (21 of 30 samples) of the time. In contrast, MN titers were within two dilutions over 96% of the time, with the highest deviation noted in acid citrate dextrose plasma samples (3 of 30 samples tested, 10%).
These data provide useful guidelines for sample collection and serology testing when screening: (i) influenza vaccine immunogenicity antibody response; (ii) antibody responses to newly emerging viral strains; and (iii) clinical samples for anti-influenza antibody activity.
The development of a safe and effective vaccine to protect against COVID-19 is a global priority due to the current high SARS-CoV-2 infection rate. Currently, there are over 160 SARS-CoV-2 vaccine ...candidates at the clinical or pre-clinical stages of development. Of these, there are only three whole-virus vaccine candidates produced using β-propiolactone or formalin inactivation. Here, we prepared a whole-virus SARS-CoV-2 vaccine (SARS-CoV-2 PsIV) using a novel psoralen inactivation method and evaluated its immunogenicity in mice using two different adjuvants, alum and Advax-2. We compared the immunogenicity of SARS-CoV-2 PsIV against SARS-CoV-2 DNA vaccines expressing either full-length or truncated spike proteins. We also compared the psoralen-inactivated vaccine against a DNA prime, psoralen-inactivated vaccine boost regimen. After two doses, the psoralen-inactivated vaccine, when administered with alum or Advax-2 adjuvants, generated a dose-dependent neutralizing antibody responses in mice. Overall, the pattern of cytokine ELISPOT responses to antigen-stimulation observed in this study indicates that SARS-CoV-2 PsIV with the alum adjuvant promotes a Th2-type response, while SARS-CoV-2 PsIV with the Advax-2 adjuvant promotes a Th1-type response.
Dengue serosurvey in Sint Eustatius Leslie, Teresa; Martin, Nicholas J; Jack-Roosberg, Carol ...
PloS one,
06/2014, Volume:
9, Issue:
6
Journal Article
Peer reviewed
Open access
Four distinct serotypes of dengue viruses (DENV) are the cause of re-emerging dengue fever (DF) and dengue hemorrhagic fever (DHF). Dengue circulation in the Caribbean has gone from none or single ...serotype to multiple serotypes co-circulating with reports of continuing cycles of progressively more severe disease in the region. Few studies have investigated dengue on Sint Eustatius. Blood samples were collected to determine the prevalence of antibodies against dengue in the Sint Eustatius population. Greater than 90% of the serum samples (184 of 204) were positive for anti-flavivirus antibodies by enzyme linked immunosorbance assay (ELISA). Plaque reduction neutralization test (PRNT), specific for dengue viruses, showed that 171 of these 184 flavivirus antibody positive sera had a neutralization titer against one or more DENV serotypes. A majority of the sera (62%) had neutralizing antibody to all four dengue serotypes. Only 26 PRNT positive sera (15%) had monotypic dengue virus neutralizing antibody, most of which (20 of 26) were against DENV2. Evidence of infection with all four serotypes was observed across all age groups except in the youngest age group (10-19 years) which contained only DENV2 positive individuals. In a multiple logistic regression model, only the length of residence on the island was a predictor of a positive dengue PRNT50 result. To our knowledge this is the first dengue serosurveillance study conducted on Sint Eustatius since the 1970s. The lack of antibodies to the DEN1, 3, and 4 in the samples collected from participants under 20 years of age suggests that only DEN2 has circulated on island since the early 1990s. The high prevalence of antibodies against dengue (83.8%) and the observation that the length of time on the island was the strongest predictor of infection suggests dengue is endemic on Sint Eustatius and a public health concern that warrants further investigation.
A tetravalent DNA vaccine for Dengue virus is under development but has not yet achieved optimal immunogenicity. Salivary glands vaccination has been reported efficacious in rodents and dogs. We ...report on a pilot study testing the salivary gland as a platform for a Dengue DNA vaccine in a non-human primate model.
Four cynomolgus macaques were used in this study. Each macaque was pre-medicated with atropine and sedated with ketamine. Stensen's duct papilla was cannulated with a P10 polyethylene tube, linked to a 500ul syringe. On the first two infusions, all macaques were infused with 300ul of TVDV mixed with 2 mg of zinc. For the 3rd infusion, to increase transfection into salivary tissue, two animals received 100uL TVDV mixed with 400uL polyethylenimine 1μg/ml (PEI) and the other two animals received 500uL TVDV with zinc. Antibody titers were assessed 4 weeks following the second and third infusion.
SGRI through Stensen's duct is a well-tolerated, simple and easy to reproduce procedure. TVDV infused into macaques salivary glands elicited a significantly weaker antibody response than with different delivery methods.