•Meibomian gland loss (MGL) higher than 50% is accompanied by signs in the ocular surface.•Age is a highly influential factor that must be taken into account when assessing the MGL.•Only corneal ...staining was correlated to MGL when age was covariant.
To assess the relationship between the meibomian gland loss (MGL) and relevant ocular surface clinical parameters as well as the influence of age in this relationship.
A total of 161 participants (mean age; 42±17 years) were enrolled in this study. Infrared meibography was performed using Keratograph 5M (K5M; Oculus GmbH, Wetzlar). Participants were divided into five groups according to total meiboscore and the ocular surface parameters of each MGL group were studied. In addition, the relationship between MGL and the ocular surface parameters was established including age as covariant.
Both eyelids were taken into account since no association between the MGL from upper and lower eyelid was found (k value=0.2; p=0.3) despite they were significantly correlated (r= 0.3; p<0.001). No statistically significant differences were found in symptomatology among different MGL groups. Statistically significant differences were found among MGL groups in tear osmolarity (p=0.02), bulbar redness (p=0.04), corneal and conjunctival staining (p=0.01 and p=0.004, respectively). Despite this, only corneal staining showed a significant correlation with MGL when age was covariant (r=0.2; p=0.04).
MGL higher than 50% seems to be accompanied by signs on the ocular surface. Furthermore, age demonstrated to be a relevant factor when assessing MGL. For this reason, future studies should compare age-matched groups in order to know the contribution of the MGL on the ocular surface and establish valid cut-off values for dry eye diagnosis.
Infrared (IR) thermography is a tool to non-invasively assess the tear film temperature. The aim was to analyze ocular surface temperature (OST) variations in dry eye disease (DED) and control eyes ...under natural non-controlled blinking conditions. Imaging was performed with a thermal camera (FLIR Systems Inc.) at 30 Hz framerate in 79 participants (39 DED (62.5% women, average age 48 ± 20 years) and 40 control (46.2 % women, average age 38 ± 13 years)) using non-contact IR thermography camera. Data acquisitions were performed in natural blinking conditions for 40 s. IR images were analyzed using a custom algorithm that calculates the OST indexes: mean OST, OST at the start and at the end, minimum and maximum OST, and tear evaporation rate (TER). No significant differences were found between groups in any thermal parameter analyzed (paired comparisons t-test, p > 0.05). In conclusion, the findings of this study did not reveal significant differences between DED and control eyes under natural non-controlled blinking conditions. However, the presence of clinical signs in the control group may affect the results, highlighting the role of DED diagnosis criteria.
This prospective, double-masked, contralateral study aimed to analyze and compare daytime changes in pre-lens tear film (PLTF) stability and optical quality in symptomatic subjects wearing two ...contact lenses (CL). A secondary goal was to assess the performance of the PLTF by using dynamic topography techniques and analyzing surface asymmetry and irregularity indexes (SAI and SRI, respectively). Measurements were conducted on 20 symptomatic subjects (OSDI score > 13). Participants were fitted contralaterally and randomly with spherical Delefilcon A and Stenfilcon A CLs and underwent a series of measurements over 3 consecutive days: three in the morning (after 1-2 h of CL wear) and three in the afternoon (after 7-9 h of CL wear). High- and low-contrast visual acuity (HCVA and LCVA, respectively), pre-lens NIBUT, and dynamic topography were assessed. The contralateral fit of the two lenses allowed a direct and better comparison between them since they were exposed to the same conditions during the day. Consequently, both lenses demonstrated similar performance in HCVA, LCVA, and PLTF stability, with no statistically significant differences between them, although some fluctuations were observed throughout the day. Dynamic topography proved sensitive in evaluating temporal changes in the PLTF. The SRI index showed greater sensitivity to topographic changes due to lacrimal destabilization, making it potentially valuable for evaluating dry eye patients.
•Previous studies suggest wearing contact lenses implies an interaction between the lens and the ocular surface.•Health and integrity of the ocular surface during and after contact lens wear was ...maintained over 15 days of wear.•There seems to be no increase in the severity of symptoms after 15 days of use.
The aim of the current study is to assess, using new technologies, the interaction of four monthly silicone hydrogel contact lenses on the ocular surface and the comfort over 15 days of use.
Prospective cross-over, randomized and double-masked study including four materials (lotrafilcon-B, samfilcon-A , comfilcon-A and filcom-V3). Clinical examination was performed in the following order: tear meniscus height, first break-up of the tear film, the average time of all tear film breakup incidents, bulbar redness, limbal redness (Keratograph 5M ,Oculus, Germany); central corneal thickness (Pentacam, Oculus, Germany), thermography values (FLIR A325; FLIR Systems Inc., USA), and slit-lamp evaluations, including ocular surface staining. Finally, subjective comfort was obtained from Contact Lens Dry Eye Questionnaire-8.
The impact of contact lens wear on the ocular surface didn’t show statistically significant changes over time except for corneal and conjunctival staining grades on day 15 compared to day 1 for the comfilcon A group (P = .003 and P = .01, respectively). Contact lens stability and impact on the ocular surface during contact lens wear didn’t show statistically significant changes over time except in the case of the comfilcon A material with respect to the irritation item (P = .01).
These results suggest that the impact of monthly silicone hydrogel contact lens materials on the ocular surface after and during contact lens wear, contact lens stability over time, and subjective comfort did not reveal any significant changes over 15 days of use for any of the materials.
To objectively and quantitatively characterize meibomian gland morphology and to investigate the influence of morphological variations on gland function and ocular surface and tear film parameters.
...One hundred fifty subjects were enrolled. The examinations included tear osmolarity, tear meniscus height, bulbar conjunctival hyperemia, noninvasive tear film breakup time, lid margin thickness, foam secretion, meibomian gland expressibility, count of functioning glands, corneal and conjunctival staining, fluorescein breakup time, lid wiper epitheliopathy, and Schirmer test. Patient symptoms were assessed using the Ocular Surface Disease Index questionnaire. Images from noncontact meibography were analyzed using an automated method that objectively estimates dropout area, number of glands, gland length and width, and gland irregularity.
Gland irregularity highly correlated with dropout area (r = -0.4, P < 0.001) and showed significant partial correlations with fluorescein breakup time (r = 0.162, P = 0.049) and the Ocular Surface Disease Index questionnaire (r = -0.250, P = 0.002) Subjects with dropout area <32% were divided into 2 groups: high and low irregularity. Gland expressibility was statistically significantly different between the 2 groups (U = 319.5, P = 0.006). In the high irregularity group, gland irregularity correlated with the Schirmer test (r = 0.530, P = 0.001) and corneal fluorescein staining (r = -0.377, P = 0.021).
Automated morphological analysis of meibomian gland structure provides additional quantitative and objective information regarding gland morphology. The link between dropout area and gland function is not clear. Assessment of gland irregularity might better predict gland function and its effects on ocular surface and tear film parameters.
Purpose
Intraocular lens designs are constantly evolving, trying to obtain more spectacle independence after cataract surgery. This advantage can be linked to some disadvantages, such as optical ...quality decrease. For that reason, it is important to assess, not only the amount of vision provided but also the quality of vision once they are implanted. The purpose of the present work was to compare the visual performance between two monofocal intraocular models: a standard model and a monofocal with enhanced intermediate vision lens.
Methods
Prospective, randomized, comparative study. Sixty adult subjects scheduled to undergo bilateral cataract surgery and IOL implantation were randomized to receive one of the two IOLs in both eyes at Miranza IOA, Madrid, Spain (group A: monofocal with enhanced intermediate vision lens and group B: standard monofocal lens). Monocular outcomes (right eyes) determined 1 and 3 months postoperatively were photopic corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), perceived halo, corrected intermediate-distance contrast sensitivity, and higher-order aberrations. The impact of the new IOL in the postoperative management with autorefraction devices was also evaluated.
Results
No differences were found in CDVA between the two groups. Significant differences were detected between the two lenses evaluated in both total HOA (
p
= 0.028) and internal HOA (
p
= 0.037). Contrast sensitivity and halometry results obtained at 1 month were similar across the two IOL groups.
Conclusion
In patients undergoing cataract surgery, monofocal with enhanced intermediate vision IOL offered similar distance performance and contrast sensitivity along with perceived HOA and halos compared with the standard monofocal IOLs tested.
To assess and compare the impact of a daily disposable contact lens (CL) with high water content on the ocular surface and comfort of the presbyopic and non-presbyopic population after one day of ...use.
Totally 20 presbyopes and 30 non-presbyopes non-contact wearers were fitted with nesofilcon A CLs. CL thickness was measured to assess material stability during daily wear, and ocular surface parameters were also assessed. Optical quality was analyzed for all cases. In addition, CL comfort was rated.
No significant differences were found in CL thickness, tear film osmolarity, average tear break-up time, bulbar redness, central corneal thickness, corneal volume, root-mean-square of higher-order aberrations (RMS of HOAs) and vertical and horizontal coma, either as a function of the group or time of use. A significant decrease in tear meniscus height and first break-up of the tear film was found in the presbyopic group (
=0.038;
=0.007 respectively). A decrease in spherical aberration coefficient was found after CL insertion (
=0.031 monofocal CL;
=0.023 low addition multifocal CL;
=0.016 high addition multifocal CL). Multifocal CL were thicker than monofocal CL (
=0.045). Comparison between groups showed more discomfort in presbyopes than non-presbyopes (
=0.003).
This study evidence that the behavior of the daily disposable CL with high water content seems to be stable during the day of use. Ocular parameters measured during wear show that CL behavior is the same for presbyopes and non-presbyopes, being more uncomfortable for presbyopes.
Objective. The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different ...blink rate (BR) patterns. Methods. A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark’Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). Results. Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. Conclusions. These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.
The inflammatory process plays a crucial role in frailty syndrome, which can appear in middle age and is associated with a poor health outcome. Consequently, gerontologists recommend screening ...inflammatory biomarkers in middle-aged adults to detect frailty and, therefore, prevent chronic diseases and mortality. External factors could be a risk factor for frailty because they can generate and extend the inflammatory process. For these reasons, we analysed the effect of long-term contact lens wear on mRNA level of genes linked to inflammation (IL-6, NLRP3, NK1R, CD73, MUC16 and TRPV1 genes) in conjunctival cells of middle-aged individuals, by quantitative PCR. Middle-aged contact lens wearers presented a significant increase of NLRP3 and MUC16 mRNA level as well as a decrease of CD73 mRNA level, in comparison with non-contact lens wearers. Additionally, we checked for a potential correlation between these transcript levels and clinical changes of the participants’ ocular surface. Unlike molecular analysis, clinical examination fails to detect inflammation in contact lens wearers. These data suggest that long-term contact lens wear could trigger an inflammatory response in middle age orchestrated by NLRP3 inflammasome and modulated by CD73 and MUC16 proteins. Further studies are needed to confirm our gene expression findings at the protein level as well as to investigate the potential role of long-term CL wear in the onset of ocular frailty.