E-resources
-
Siskos, Alexandros P; Jain, Pooja; Römisch-Margl, Werner; Bennett, Mark; Achaintre, David; Asad, Yasmin; Marney, Luke; Richardson, Larissa; Koulman, Albert; Griffin, Julian L; Raynaud, Florence; Scalbert, Augustin; Adamski, Jerzy; Prehn, Cornelia; Keun, Hector C
Analytical chemistry (Washington), 01/2017, Volume: 89, Issue: 1Journal Article
A critical question facing the field of metabolomics is whether data obtained from different centers can be effectively compared and combined. An important aspect of this is the interlaboratory precision (reproducibility) of the analytical protocols used. We analyzed human samples in six laboratories using different instrumentation but a common protocol (the AbsoluteIDQ p180 kit) for the measurement of 189 metabolites via liquid chromatography (LC) or flow injection analysis (FIA) coupled to tandem mass spectrometry (MS/MS). In spiked quality control (QC) samples 82% of metabolite measurements had an interlaboratory precision of <20%, while 83% of averaged individual laboratory measurements were accurate to within 20%. For 20 typical biological samples (serum and plasma from healthy individuals) the median interlaboratory coefficient of variation (CV) was 7.6%, with 85% of metabolites exhibiting a median interlaboratory CV of <20%. Precision was largely independent of the type of sample (serum or plasma) or the anticoagulant used but was reduced in a sample from a patient with dyslipidaemia. The median interlaboratory accuracy and precision of the assay for standard reference plasma (NIST SRM 1950) were 107% and 6.7%, respectively. Likely sources of irreproducibility were the near limit of detection (LOD) typical abundance of some metabolites and the degree of manual review and optimization of peak integration in the LC-MS/MS data after acquisition. Normalization to a reference material was crucial for the semi-quantitative FIA measurements. This is the first interlaboratory assessment of a widely used, targeted metabolomics assay illustrating the reproducibility of the protocol and how data generated on different instruments could be directly integrated in large-scale epidemiological studies.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.