Bhardwaj, Jyoti; Sharma, Abhinav; Jang, Jaesung
Biosensors & bioelectronics, 02/2019, Volume: 126Journal Article
We present a novel vertical flow-based paper immunosensor for the rapid and sensitive electrochemical and colorimetric detection of influenza H1N1 viruses using a different pore size (DP) sample pad. The DP sample pad consisted of two different pore size papers: larger pores (diameter: 11 µm) facing the inlet, and smaller pores (diameter: 0.45 µm) facing the conjugate pad. This sample pad offered moderate and uniform flows, and hence concentrated horseradish peroxidase tagged antibodies (HRP-Abs)-H1N1 complexes from 40 µL of sample volumes on a conjugate pad for 2 min after sample injection, thereby providing fast detection (6 min for both detection methods) with 100 µL of flushing afterwards, high sensitivity, and the simplicity of the sensor. The filtration characteristics of the DP sample pad were evaluated using fluorescent beads, indicating that only small-sized bio-particles such as viruses can pass through the sample pad. Sandwich immunoreactions of HRP-Ab-H1N1-Ab were performed on the gold paper electrode of the immunoStrip, which was determined by electrochemical impedance spectroscopy (EIS) measurements. Simultaneously, the color signal of free HRP-Ab captured on the colorimetric zone was obtained using a scanner, and the intensity was analyzed using ImageJ. This immunosensor detected H1N1 virus concentration as low as 3.3 plaque forming units (PFU)/mL (phosphate buffer saline; PBS) and 4.7 PFU/mL (saliva) by EIS, and 1.34 PFU/mL (PBS) and 2.27 PFU/mL (saliva) by the colorimetric method. Furthermore, integrating these two detection methods can reduce false results with double assurance, and this device can provide a simple and economical on-site detection platform. •The first paper immunosensor using a double pore size (DP) sample pad.•The first vertical flow assay-based, sandwich ELISA-type paper immunosensor for the detection of influenza viruses.•Dual (electrochemical and colorimetric) detection methods to provide double assurance.•The DP sample pad offered fast detection (~6 min), high sensitivity (the limit of detection <5 PFU/mL), and the simplicity.•The DP sample pad also acted as a filter to pass only small-sized particles.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.