Guenego, Adrien; Mosimann, Pascal J.; Pereira, Vitor Mendes; Nicholson, Patrick; Zuber, Kevin; Lotterie, Jean Albert; Dobrocky, Tomas; Marcellus, David G.; Olivot, Jean Marc; Piotin, Michel; Gralla, Jan; Fahed, Robert; Wintermark, Max; Heit, Jeremy J.; Cognard, Christophe
European radiology, 07/2019, Volume: 29, Issue: 7Journal Article
Background International dose reference levels are lacking for mechanical thrombectomy in acute ischemic stroke patients with large vessel occlusions. We studied whether radiation dose-reduction systems (RDS) could effectively reduce exposure and propose achievable levels. Materials and methods We retrospectively included consecutive patients treated with thrombectomy on a biplane angiography system (BP) in five international, high-volume centers between January 2014 and May 2017. Institutional Review Board approvals were obtained. Technical, procedural, and clinical characteristics were assessed. Efficacy, safety, radiation dose, and contrast load were compared between angiography systems with and without RDS. Multivariate analyses were adjusted according to Bonferroni’s correction. Proposed international achievable cutoff levels were set at the 75th percentile. Results Out of the 1096 thrombectomized patients, 520 (47%) were treated on a BP equipped with RDS. After multivariate analysis, RDS significantly reduced dose–area product (DAP) (91 vs 140 Gy cm 2 , relative effect 0.74 (CI 0.66; 0.83), 35% decrease, p < 0.001) and air kerma (0.46 vs 0.97 Gy, relative effect 0.63 (CI 0.56; 0.71), 53% decrease, p < 0.001) with 75th percentile levels of 148 Gy cm 2 and 0.73 Gy, respectively. There was no difference in contrast load, rates of successful recanalization, complications, or clinical outcome. Conclusion Radiation dose-reduction systems can reduce DAP and air kerma by a third and a half, respectively, without affecting thrombectomy efficacy or safety. The respective thresholds of 148 Gy cm 2 and 0.73 Gy represent achievable levels that may serve to optimize current and future radiation exposure in the setting of acute ischemic stroke treatment. As technology evolves, we expect these values to decrease. Key Points • Internationally validated achievable levels may help caregivers and health authorities better assess and reduce radiation exposure of both ischemic stroke patients and treating staff during thrombectomy procedures. • Radiation dose-reduction systems can reduce DAP and air kerma by a third and a half, respectively, without affecting thrombectomy efficacy or safety in the setting of acute ischemic stroke due to large vessel occlusion.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.