E-resources
-
Saugel, Bernd; Hoppe, Phillip; Nicklas, Julia Y.; Kouz, Karim; Körner, Annmarie; Hempel, Julia C.; Vos, Jaap J.; Schön, Gerhard; Scheeren, Thomas W.L.
British journal of anaesthesia : BJA, July 2020, 2020-07-00, 20200701, Volume: 125, Issue: 1Journal Article
Finger cuff technologies allow continuous noninvasive arterial blood pressure (AP) and cardiac output/index (CO/CI) monitoring. We performed a meta-analysis of studies comparing finger cuff-derived AP and CO/CI measurements with invasive measurements in surgical or critically ill patients. We calculated overall random effects model-derived pooled estimates of the mean of the differences and of the percentage error (PE; CO/CI studies) with 95%-confidence intervals (95%-CI), pooled 95%-limits of agreement (95%-LOA), Cochran's Q and I2 (for heterogeneity). The pooled mean of the differences (95%-CI) was 4.2 (2.8 to 5.62) mm Hg with pooled 95%-LOA of –14.0 to 22.5 mm Hg for mean AP (Q=230.4 P<0.001, I2=91%). For mean AP, the mean of the differences between finger cuff technologies and the reference method was ≤5±8 mm Hg in 9/27 data sets (33%). The pooled mean of the differences (95%-CI) was –0.13 (–0.43 to 0.18) L min−1 with pooled 95%-LOA of –2.56 to 2.23 L min−1 for CO (Q=66.7 P<0.001, I2=90%) and 0.07 (0.01 to 0.13) L min−1 m−2 with pooled 95%-LOA of –1.20 to 1.15 L min−1 m−2 for CI (Q=5.8 P=0.326, I2=0%). The overall random effects model-derived pooled estimate of the PE (95%-CI) was 43 (37 to 49)% (Q=48.6 P<0.001, I2=63%). In 4/19 data sets (21%) the PE was ≤30%, and in 10/19 data sets (53%) it was ≤45%. Study heterogeneity was high. Several studies showed interchangeability between AP and CO/CI measurements using finger cuff technologies and reference methods. However, the pooled results of this meta-analysis indicate that AP and CO/CI measurements using finger cuff technologies and reference methods are not interchangeable in surgical or critically ill patients. PROSPERO registration number: CRD42019119266.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.