UP - logo
Fakulteta za strojništvo, Ljubljana (FSLJ)
  • Performance analysis of close loop thermosiphon solar system
    Turk, Jani ; Medved, Sašo ; Novak, Peter, 1937-
    In this paper an analytical mathematical model of close loop thermosiphon solar system with experimental verification have been presented. Two deferent types of thermosiphon loop heat exchanger were ... examine: internal coil and external jacked heat exchanger. Aperture area of solar collector is 2 m^2 and volume of heat storage is 0.12 m^3. In all experiments as a fluid of heat transfer a 50% mixture of glycol and water was used. An analyses of influence on the efficiency of close loop thermosiphon solar system by some parameters was made too.
    Vrsta gradiva - prispevek na konferenci
    Leto - 1989
    Jezik - angleški
    COBISS.SI-ID - 2508827