Familial hypercholesterolemia (FH) is clearly underdiagnosed and undertreated. The aim of this present study is to assess the benefits of FH screening through a joint national program implemented ...between clinical laboratories and lipid units.
All clinical laboratory tests from 1 January 2017 to 31 December 2018 were reviewed, and those with LDL cholesterol (LDL-C) levels >250 mg/dl were identified in subjects >18 years of age of both sexes. Once secondary causes had been ruled out, the treating physician was contacted and advised to refer the patient to an LU to perform the Dutch Lipid Clinic Network score and to request genetic testing if the score was ≥6 points. Next Generation Sequencing was used to analyse the promoter and coding DNA sequences of four genes associated with FH (
) and two genes that have a clinical overlap with FH characteristics (
and
). A polygenic risk score based on 12 variants was also obtained.
Of the 3,827,513 patients analyzed in 26 centers, 6,765 had LDL-C levels >250 mg/dl. Having ruled out secondary causes and known cases of FH, 3,015 subjects were included, although only 1,205 treating physicians could be contacted. 635 patients were referred to an LU and genetic testing was requested for 153 of them. This resulted in a finding of sixty-seven pathogenic variants for FH, 66 in the
gene and one in
. The polygenic risk score was found higher in those who had no pathogenic variant compared to those with a pathogenic variant.
Despite its limitations, systematic collaboration between clinical laboratories and lipid units allows for the identification of large numbers of patients with a phenotypic or genetic diagnosis of FH, which will reduce their vascular risk. This activity should be part of the clinical routine.
Handling of lipemic samples in the clinical laboratory Fernández Prendes, Carla; Castro Castro, María José; Sánchez Navarro, Lourdes ...
Advances in Laboratory Medicine / Avances en Medicina de Laboratorio,
04/2023, Letnik:
4, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Interferences in the clinical laboratory may lead physicians misinterpret results for some biological analytes. The most common analytical interferences in the clinical laboratory include hemolysis, ...icterus and lipemia. Lipemia is defined as turbidity in a sample caused by the accumulation of lipoproteins, mainly very-low density lipoproteins (VLDL) and chylomicrons. Several methods are available for the detection of lipemic samples, including the lipemic index, or triglyceride quantification in serum or plasma samples, or mean corpuscular hemoglobin (MCHC) concentration in blood samples. According to the European Directive 98/79/CE, it is the responsibility of clinical laboratories to monitor the presence of interfering substances that may affect the measurement of an analyte. There is an urgent need to standardize interference studies and the way interferences are reported by manufacturers. Several methods are currently available to remove interference from lipemia and enable accurate measurement of biological quantities. The clinical laboratory should establish a protocol for the handling of lipemic samples according to the biological quantity to be tested.
Cardiovascular diseases continue to lead the ranking of mortality in Spain. The implementation of geostatistical analysis techniques in the clinical laboratory are innovative tools that allow the ...design of new strategies in primary prevention of cardiovascular disease. The aim of this study was to study the prevalence and geolocation of severe dyslipidemia in the health areas under study in order to implement prevention strategies in primary care. A retrospective cohort study of low-density protein-bound cholesterol, triglyceride and lipoprotein (a) levels in the years 2019 and 2020 were carried out. In addition, a geostatistical analysis was performed including representation in choropleth maps and the detection of clustering clusters, using geographic information in zip code format included in the demographic data of each analytic.
The analytical data included in the study were triglycerides (n=365,384), low density protein-bound cholesterol (n=289,594) and lipoprotein to lipoprotein (a) (n=502). Areas with the highest and lowest percentage of cases were identified for the established cut-off points of LDL-C>190mg/dL and TG>150mg/dL. Two clustering clusters with statistical significance were detected for cLDL>190mg/dL and a total of 6 clusters for TG values>150mg/dL.
The detection of clusters, as well as the representation of choropleth maps, can be of great help in detecting geographic areas that require greater attention to intervene and improve cardiovascular risk.
Cardiovascular diseases (CVD) continue to be the main cause of death in our country. Adequate control of lipid metabolism disorders is a key challenge in cardiovascular prevention that is far from ...being achieved in real clinical practice. There is a great heterogeneity in the reports of lipid metabolism from Spanish clinical laboratories, which may contribute to its poor control. For this reason, a working group of the main scientific societies involved in the care of patients at vascular risk, has prepared this document with a consensus proposal on the determination of the basic lipid profile in cardiovascular prevention, recommendations for its realization and unification of criteria to incorporate the lipid control goals appropriate to the vascular risk of the patients in the laboratory reports.
Las enfermedades cardiovasculares (ECV) siguen siendo la principal causa de muerte en nuestro país. El control adecuado de las alteraciones del metabolismo lipídico es un reto clave en prevención ...cardiovascular que está lejos de alcanzarse en la práctica clínica real. Existe una gran heterogeneidad en los informes del metabolismo lipídico de los laboratorios clínicos españoles, lo que puede contribuir al mal control del mismo. Por ello, un grupo de trabajo de las principales sociedades científicas implicadas en la atención de los pacientes de riesgo vascular hemos elaborado este documento con una propuesta básica de consenso sobre la determinación del perfil lipídico básico en prevención cardiovascular, recomendaciones para su realización y unificación de criterios para incorporar los objetivos de control lipídico adecuados al riesgo vascular de los pacientes en los informes de laboratorio.
Cardiovascular diseases (CVD) continue to be the main cause of death in our country. Adequate control of lipid metabolism disorders is a key challenge in cardiovascular prevention that is far from ...being achieved in real clinical practice. There is a great heterogeneity in the reports of lipid metabolism from Spanish clinical laboratories, which may contribute to its poor control. For this reason, a working group of the main scientific societies involved in the care of patients at vascular risk, has prepared this document with a consensus proposal on the determination of the basic lipid profile in cardiovascular prevention, recommendations for its realization and unification of criteria to incorporate the lipid control goals appropriate to the vascular risk of the patients in the laboratory reports.
Display omitted
Las enfermedades cardiovasculares (ECV) siguen siendo la principal causa de muerte en nuestro país. El control adecuado de las alteraciones del metabolismo lipídico es un reto clave ...en prevención cardiovascular que está lejos de alcanzarse en la práctica clínica real. Existe una gran heterogeneidad en los informes del metabolismo lipídico de los laboratorios clínicos españoles, lo que puede contribuir al mal control del mismo. Por ello, un grupo de trabajo de las principales sociedades científicas implicadas en la atención de los pacientes de riesgo vascular hemos elaborado este documento con una propuesta básica de consenso sobre la determinación del perfil lipídico básico en prevención cardiovascular, recomendaciones para su realización y unificación de criterios para incorporar los objetivos de control lipídico adecuados al riesgo vascular de los pacientes en los informes de laboratorio.
Cardiovascular diseases (CVD) continue to be the main cause of death in our country. Adequate control of lipid metabolism disorders is a key challenge in cardiovascular prevention that is far from being achieved in real clinical practice. There is a great heterogeneity in the reports of lipid metabolism from Spanish clinical laboratories, which may contribute to its poor control. For this reason, a working group of the main scientific societies involved in the care of patients at vascular risk, has prepared this document with a consensus proposal on the determination of the basic lipid profile in cardiovascular prevention, recommendations for its realization and unification of criteria to incorporate the lipid control goals appropriate to the vascular risk of the patients in the laboratory reports.
Lipemia, a significant source of analytical errors in clinical laboratory settings, should be removed prior to measuring biochemical parameters. We investigated whether lipemia in serum/plasma ...samples can be removed using a method that is easier and more practicable than ultracentrifugation, the current reference method.
Seven hospital laboratories in Spain participated in this study. We first compared the effectiveness of ultracentrifugation (108,200×g) and high-speed centrifugation (10,000×g for 15 minutes) in removing lipemia. Second, we compared high-speed centrifugation with two liquid-liquid extraction methods-LipoClear (StatSpin, Norwood, USA), and 1,1,2-trichlorotrifluoroethane (Merck, Darmstadt, Germany). We assessed 14 biochemical parameters: serum/plasma concentrations of sodium ion, potassium ion, chloride ion, glucose, total protein, albumin, creatinine, urea, alkaline phosphatase, gamma-glutamyl transferase, alanine aminotransferase, aspartate-aminotransferase, calcium, and bilirubin. We analyzed whether the differences between lipemia removal methods exceeded the limit for clinically significant interference (LCSI).
When ultracentrifugation and high-speed centrifugation were compared, no parameter had a difference that exceeded the LCSI. When high-speed centrifugation was compared with the two liquid-liquid extraction methods, we found differences exceeding the LCSI in protein, calcium, and aspartate aminotransferase in the comparison with 1,1,2-trichlorotrifluoroethane, and in protein, albumin, and calcium in the comparison with LipoClear. Differences in other parameters did not exceed the LCSI.
High-speed centrifugation (10,000×g for 15 minutes) can be used instead of ultracentrifugation to remove lipemia in serum/plasma samples. LipoClear and 1,1,2-trichlorotrifluoroethane are unsuitable as they interfere with the measurement of certain parameters.
Display omitted
Las enfermedades cardiovasculares (ECV) siguen siendo la principal causa de muerte en nuestro país. El control adecuado de las alteraciones del metabolismo lipídico es un reto clave ...en prevención cardiovascular que está lejos de alcanzarse en la práctica clínica real. Existe una gran heterogeneidad en los informes del metabolismo lipídico de los laboratorios clínicos españoles, lo que puede contribuir al mal control del mismo. Por ello, un grupo de trabajo de las principales sociedades científicas implicadas en la atención de los pacientes de riesgo vascular hemos elaborado este documento con una propuesta básica de consenso sobre la determinación del perfil lipídico básico en prevención cardiovascular, recomendaciones para su realización y unificación de criterios para incorporar los objetivos de control lipídico adecuados al riesgo vascular de los pacientes en los informes de laboratorio.
Cardiovascular diseases (CVD) continue to be the main cause of death in our country. Adequate control of lipid metabolism disorders is a key challenge in cardiovascular prevention that is far from being achieved in real clinical practice. There is a great heterogeneity in the reports of lipid metabolism from Spanish clinical laboratories, which may contribute to its poor control. For this reason, a working group of the main scientific societies involved in the care of patients at vascular risk, has prepared this document with a consensus proposal on the determination of the basic lipid profile in cardiovascular prevention, recommendations for its realization and unification of criteria to incorporate the lipid control goals appropriate to the vascular risk of the patients in the laboratory reports.
Cardiovascular diseases (CVD) continue to be the main cause of death in our country. Adequate control of lipid metabolism disorders is a key challenge in cardiovascular prevention that is far from ...being achieved in real clinical practice. There is a great heterogeneity in the reports of lipid metabolism from Spanish clinical laboratories, which may contribute to its poor control. For this reason, a working group of the main scientific societies involved in the care of patients at vascular risk, has prepared this document with a consensus proposal on the determination of the basic lipid profile in cardiovascular prevention, recommendations for its realization and unification of criteria to incorporate the lipid control goals appropriate to the vascular risk of the patients in the laboratory reports.
Las enfermedades cardiovasculares (ECV) siguen siendo la principal causa de muerte en nuestro pais. El control adecuado de las alteraciones del metabolismo lipidico es un reto clave en prevencion cardiovascular que esta lejos de alcanzarse en la practica clinica real. Existe una gran heterogeneidad en los informes del metabolismo lipidico de los laboratorios clinicos españoles, lo que puede contribuir al mal control del mismo. Por ello, un grupo de trabajo de las principales sociedades cientificas implicadas en la atencion de los pacientes de riesgo vascular hemos elaborado este documento con una propuesta basica de consenso sobre la determinacion del perfil lipidico basico en prevencion cardiovascular, recomendaciones para su realizacion y unificacion de criterios para incorporar los objetivos de control lipidico adecuados al riesgo vascular de los pacientes en los informes de laboratorio.