The KASCADE-Grande experiment Apel, W.D.; Arteaga, J.C.; Badea, A.F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/2010, Letnik:
620, Številka:
2
Journal Article
Recenzirano
Odprti dostop
KASCADE-Grande is the enlargement of the KASCADE extensive air shower detector, realized to expand the cosmic ray studies from the previous 10
14–10
17
eV primary energy range to 10
18
eV. This is ...performed by extending the area covered by the KASCADE electromagnetic array from 200×200 to 700×700
m
2 by means of 37 scintillator detector stations of 10
m
2 area each. This new array is named Grande and provides measurements of the all-charged particle component of extensive air showers (
N
ch
), while the original KASCADE array particularly provides information on the muon content
(
N
μ
)
. Additional dense compact detector set-ups being sensitive to energetic hadrons and muons are used for data consistency checks and calibration purposes. The performance of the Grande array and its integration into the entire experimental complex is discussed. It is demonstrated that the overall observable resolutions are adequate to meet the physical requirements of the measurements, i.e. primary energy spectrum and elemental composition studies in the primary cosmic ray energy range of 10
16–10
18
eV.
A composition analysis of KASCADE air shower data is performed by means of unfolding the two-dimensional frequency spectrum of electron and muon numbers. Aim of the analysis is the determination of ...energy spectra for elemental groups representing the chemical composition of primary cosmic rays. Since such an analysis depends crucially on simulations of air showers the two different hadronic interaction models QGSJet and SIBYLL are used for their generation. The resulting primary energy spectra show that the knee in the all particle spectrum is due to a steepening of the spectra of light elements but, also, that neither of the two simulation sets is able to describe the measured data consistently over the whole energy range with discrepancies appearing in different energy regions.
The nature of ultrahigh-energy cosmic rays (UHECRs) at energies >1020 eV remains a mystery. They are likely to be of extragalactic origin, but should be absorbed within ∼50 Mpc through interactions ...with the cosmic microwave background. As there are no sufficiently powerful accelerators within this distance from the Galaxy, explanations for UHECRs range from unusual astrophysical sources to exotic string physics. Also unclear is whether UHECRs consist of protons, heavy nuclei, neutrinos or γ-rays. To resolve these questions, larger detectors with higher duty cycles and which combine multiple detection techniques are needed. Radio emission from UHECRs, on the other hand, is unaffected by attenuation, has a high duty cycle, gives calorimetric measurements and provides high directional accuracy. Here we report the detection of radio flashes from cosmic-ray air showers using low-cost digital radio receivers. We show that the radiation can be understood in terms of the geosynchrotron effect. Our results show that it should be possible to determine the nature and composition of UHECRs with combined radio and particle detectors, and to detect the ultrahigh-energy neutrinos expected from flavour mixing.
The KASCADE experiment measures extensive air showers induced by cosmic rays in the energy range around the so-called knee. The data of KASCADE have been used in a composition analysis showing the ...knee at 3–5
PeV to be caused by a steepening in the light-element spectra T. Antoni et al., (KASCADE Coll.), Astropart. Phys. 24 (2005) 1–25. Since the applied unfolding analysis depends crucially on simulations of air showers, different high-energy hadronic interaction models (QGSJet and SIBYLL) were used. The results have shown a strong dependence of the relative abundance of the individual mass groups on the underlying model. In this update of the analysis we apply the unfolding method with a different low energy interaction model (FLUKA instead of GHEISHA) in the simulations. While the resulting individual mass group spectra do not change significantly, the overall description of the measured data improves by using the FLUKA model. In addition data in a larger range of zenith angle are analysed. The new results are completely consistent, i.e. there is no hint to any severe problem in applying the unfolding analysis method to KASCADE data.
The antenna array LOPES is set up at the location of the KASCADE-Grande extensive air shower experiment in Karlsruhe, Germany and aims to measure and investigate radio pulses from extensive air ...showers. The coincident measurements allow us to reconstruct the electric field strength at observation level in dependence of general EAS parameters. In the present work, the lateral distribution of the radio signal in air showers is studied in detail. It is found that the lateral distributions of the electric field strengths in individual EAS can be described by an exponential function. For about 20% of the events a flattening towards the shower axis is observed, preferentially for showers with large inclination angle. The estimated scale parameters
R
0
, describing the slope of the lateral profiles range between 100 and 200
m. No evidence for a direct correlation of
R
0
with shower parameters like azimuth angle, geomagnetic angle, or primary energy can be found. This indicates that the lateral profile is an intrinsic property of the radio emission during the shower development which makes the radio detection technique suitable for large scale applications.
Computed tomography (CT) is the standard imaging test used for the screening and assessment of suspected lung cancer, but distinguishing malignant from benign nodules by CT is an ongoing challenge. ...Consequently, a large number of avoidable invasive procedures are performed on patients with benign nodules in order to exclude malignancy. Improving cancer discrimination by non-invasive imaging could reduce the need for invasive diagnostics. In this work we focus on developing a gold nanoparticle contrast agent that targets the epidermal growth factor receptor (EGFR), which is expressed on the cell surface of most lung adenocarcinomas. Three different contrast agents were compared for their tumor targeting effectiveness: non-targeted nanoparticles, nanoparticles conjugated with full-sized anti-EGFR antibodies (cetuximab), and nanoparticles conjugated with a single-domain llama-derived anti-EGFR antibody, which is smaller than the cetuximab, but has a lower binding affinity. Nanoparticle targeting effectiveness was evaluated in vitro by EGFR-binding assays and in cell culture with A431 cells, which highly express EGFR. In vivo CT imaging performance was evaluated in both C57BL/6 mice and in nude mice with A431 subcutaneous tumors. The cetuximab nanoparticles had a significantly shorter blood residence time than either the non-targeted or the single-domain antibody nanoparticles. All of the nanoparticle contrast agents demonstrated tumor accumulation; however, the cetuximab-targeted group had significantly higher tumor gold accumulation than the other two groups, which were statistically indistinguishable from one another. In this study we found that the relative binding affinity of the targeting ligands had more of an effect on tumor accumulation than the circulation half life of the nanoparticles. This study provides useful insight into targeted nanoparticle design and demonstrates that nanoparticle contrast agents can be used to detect tumor receptor overexpression. Combining receptor status data with traditional imaging characteristics has the potential for better differentiation of malignant lung tumors from benign lesions.
We present the results of an analysis of the large-scale anisotropy of cosmic rays in the PeV range. The Rayleigh formalism is applied to the right ascension distribution of extensive air showers ...measured by the KASCADE (Karlsruhe Shower Core and Array Detector) experiment. The data set contains about 10 super(8) extensive air showers in the energy range 0.7-6 PeV. No hints of anisotropy are visible in the right ascension distributions in this energy range. This accounts for all showers, as well as for subsets containing showers induced by predominantly light or heavy primary particles, respectively. Upper flux limits for Rayleigh amplitudes are determined to be between 10 super(-3) at a primary energy of 0.7 PeV and 10 super(-2) at 6 PeV.
Lateral distributions for electrons and muons in extensive air showers measured with the array of the KASCADE experiment are compared to results of simulations based on the high-energy hadronic ...interaction models QGSJet and SIBYLL. It is shown, that the muon distributions are well described by both models. Deviations are found for the electromagnetic component, where both models predict a steeper lateral shape than observed in the data. For both models the observed lateral shapes of the electron component indicate a transition from a light to a more heavy composition of the cosmic ray spectrum above the knee.
Aim: To demonstrate the feasibility of the 3D ultrasound periodontal tissue reconstruction of the lateral area of a porcine mandible using standard 2D ultrasound equipment and spatial positioning ...reading sensors. Material and method: Periodontal 3D reconstructions were performed using a free-hand prototype based on a 2D US scanner and a spatial positioning reading sensor. For automated data processing, deep learning algorithms were implemented and trained using semi-automatically seg-mented images by highly specialized imaging professionals. Results: US probe movement analysis showed that non-parallel 2D frames were acquired during the scanning procedure. Comparing 3 different 3D periodontal reconstructions of the same porcine mandible, the accuracy ranged between 0.179 mm and 0.235 mm. Conclusion: The present study demonstrated the diagnostic potential of 3D reconstruction using a free-hand 2D US scanner with spatial positioning readings. The use of auto-mated data processing with deep learning algorithms makes the process practical in the clinical environment for assessment of periodontal soft tissues.
A survey of the northern hemisphere for astrophysical point sources with continuous emission of high-energy cosmic rays is presented. Around 4.7 x 10 super(7) extensive air showers with primary ...energies above ~300 TeV measured by the KASCADE detector field are selected for this analysis. Besides the sky survey, a search for signal excess in the regions of the Galactic plane and of selected point-source candidates has been performed. There is no evidence for any significant excess. This is valid for an analysis of all recorded showers, as well as for a data set enhanced by gamma-ray-induced showers. An upper flux limit of around 3 x 10 super(-10) m super(-2) s super(-1) for a steady point source that transits the zenith is obtained. Additionally, the distribution of the arrival directions of extensive air showers with energies above 80 PeV was studied by an autocorrelation analysis.