Further studies on a DTBX prototype for the CMS muon detector at LHC Barichello, G; Bencze, Gy.-L; Benvenuti, A ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/1995, Letnik:
360, Številka:
3
Journal Article
Recenzirano
Odprti dostop
The performance of a small prototype chamber of the baseline project for the muon barrel detector for CMS has been studied in a muon beam. Its efficiency with different gases and wire diameters, the ...trigger possibilities and the response in presence of a large number of electromagnetic secondaries associated to the muon are evaluated. The results are compared with a full Monte Carlo simulation.
We present the results of beam tests with high-energy (8–375 GeV) electrons, pions, protons and muons of a sampling calorimeter based on the detection of Cherenkov light produced by shower particles. ...The detector, a prototype for the very forward calorimeters in the CMS experiment, consists of thin quartz fibers embedded in a copper matrix. Results are given on the light yield of this device, on its energy resolution for electron and hadron detection, and on the signal uniformity and linearity. The signal generation mechanism gives this type of detector unique properties, especially for the detection of hadron showers: narrow, shallow shower profiles and extremely fast signals. These specific properties were measured in detail. The implications for measurements in the high-rate, high-radiation Large Hadron Collider (LHC) environment are discussed.
The experiments at the Large Hadron Collider (LHC) will have to deal with unprecedented radiation levels. In the large-rapidity regions, close to the beam pipe, these levels reach megagrays per year. ...The detectors to be installed in these regions, the HF Calorimeters, are designed to operate under these conditions. In this paper, we describe the results of studies in which a prototype calorimeter was exposed to radiation of the type and intensity expected at the LHC. These studies made it possible to estimate the effects of this radiation on the response and the resolution of the calorimeter as a function of time during LHC operation.
A prototype module of an iron-gas sampling calorimeter based on parallel-plate chambers, full-size depth, has been tested using high-energy muons, electrons and pions. The module was equipped with ...more than 1000 active cells read out individually. Experimental measurements at the test beam and their comparison with Monte-Carlo simulations are presented. Expected performance for a calorimeter suitable for low-angle regions in LHC experiments are derived.
The general scheme for the fast, pipelined first level trigger on high
p
t muons in the CMS detector at LHC is presented. The prototype PACT system was tested in the high momentum muon beams in the ...RD5 experiment during 1993/94 runs. The obtained efficiency curves are shown.
This document presents an overview of the induced photocurrents in the Amorphous Silicon Position Detectors used in the network of diode lasers and photo sensors of the CMS Link alignment system ...recorded during its eleven years of operation. After a description of the sensors characteristics, the layout of the sensors network is discussed. The sensors are distributed throughout the muon spectrometer and connected by laser lines. The data used correspond to readout information obtained during some of the physics runs from 2008 to 2018.