BACKGROUND. This paper examined the hypothesis that males with first-episode psychosis (FEP) experience lower pre-morbid adjustment, greater social disability and more self-perceived needs at illness ...onset than females(by controlling for duration of untreated psychosis, diagnosis, age and symptoms at onset). Results disconfirming this hypothesis were thought to suggest the potentially mediating role of social context in determining the impact of symptoms and disability on the everyday lives of male patients in the early phase of psychosis. METHOD. A large epidemiologically representative cohort of FEP patients (n=517) was assessed within the Psychosis Incident Cohort Outcome Study (PICOS) framework – a multi-site research project examining incident cases of psychosis in Italy's Veneto region. RESULTS. Despite poorer pre-morbid functioning and higher social disability at illness onset, males reported fewer unmet needs in the functioning domain than females did. An analysis of help provided by informal care givers showed that males received more help from their families than females did. This finding led us to disconfirm the second part of the hypothesis and suggest that the impact of poorer social performance and unmet needs on everyday life observed in male patients might be hampered by higher tolerance and more support within the family context.CONCLUSIONS. These findings shed new light on rarely investigated sociocultural and contextual factors that may account for the observed discrepancy between social disability and needs for care in FEP patients. They also point to a need for further research on gender differences, with the ultimate aim of delivering gender-sensitive effective mental health care.
Micro Pattern Gas Detectors (MPGD) are the new frontier in gas trackers. Among this kind of devices, the Gas Electron Multiplier (GEM) chambers are widely used. The experimental signals acquired with ...the detector must obviously be reconstructed and analysed. In this contribution, a new offline software to perform reconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICs will be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measure the performance of a MPGD detector with a strip segmented anode (presently). The code is divided in three parts: reconstruction, where the hits are digitized and clusterized; tracking, where a procedure fits the points from the tracking system and uses that information to align the chamber with rotations and shifts; analysis, where the performance is evaluated (e.g. efficiency, spatial resolution,etc.). The user must set the geometry of the setup and then the program returns automatically the analysis results, taking care of different conditions of gas mixture, electric field, magnetic field, geometries, strip orientation, dead strip, misalignment and many others.
An overview of the experimental results achieved so far by the FINUDA experiment 1 in the search of deeply bound kaonic aggregates with two or three baryons is reported.
The experiment BESIII, running at the accelerator BEPCII in Beijing (P.R.C.), is going to be updated with the replacement of the Inner Drift Chamber with a Cylindrical triple-GEM Inner Tracker ...(CGEM-IT). In the R&D stage, two standalone C++ codes were implemented: GTS (Garfield-based Triple-GEM Simulator), for digitization and tuning of simulated data to the experimental ones, and GRAAL (GEM Reconstruction And Analysis Library), for the reconstruction and analysis of the experimental events collected in testbeams. GTS simulates the triple-GEM response to the particle passage, treating each stage separately: ionization, GEM properties, gas mixture, magnetic field and finally the induction of the signal on the anode. The necessary information was extracted by GARFIELD++ simulations, parametrized and used as input in GTS. This speeds up the simulation, since GTS performs only samplings instead of the full digitization chain. The simulated events were reconstructed with the same procedure used for experimental data and tuning factors were evaluated to obtain a satisfactory match. GRAAL is used in the analysis of the testbeam experimental data. It provides several levels of reconstruction: from the cluster formation, gathering contiguous firing strips, to the spatial position and the signal time reconstruciton. Two algorithms are used: the charge centroid and the micro-TPC, which exploit the charge deposition on the strips and the time information. Also a merging of the two algorithms is available to efficiently weight the two outcomes and obtain the best estimate of the spatial coordinate. Moreover, GRAAL performs tracking and alignment. Both codes are going to be made available also for other MPGDs simulation and reconstruction.
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be ...developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.
Previous studies of proton and neutron spectra from Non-Mesonic Weak Decay of eight Λ-Hypernuclei (A=5–16) have been revisited. New values of the ratio of the two-nucleon and the one-proton induced ...decay widths, Γ2N/Γp, are obtained from single proton spectra, Γ2N/Γp=0.50±0.24, and from neutron and proton coincidence spectra, Γ2N/Γp=0.36±0.14stat−0.04sys+0.05sys, in full agreement with previously published ones. With these values, a method is developed to extract the one-proton induced decay width in units of the free Λ decay width, Γp/ΓΛ, without resorting to Intra Nuclear Cascade models but by exploiting only experimental data, under the assumption of a linear dependence on A of the Final State Interaction contribution. This is the first systematic determination ever done and it agrees within the errors with recent theoretical calculations.