The Compact Linear Collider (CLIC) is an option for a future
e
+
e
-
collider operating at centre-of-mass energies up to
3
TeV
, providing sensitivity to a wide range of new physics phenomena and ...precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages:
s
=
350
GeV
, 1.4 and
3
TeV
. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung (
e
+
e
-
→
Z
H
) and
W
W
-fusion (
e
+
e
-
→
H
ν
e
ν
¯
e
), resulting in precise measurements of the production cross sections, the Higgs total decay width
Γ
H
, and model-independent determinations of the Higgs couplings. Operation at
s
>
1
TeV
provides high-statistics samples of Higgs bosons produced through
W
W
-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes
e
+
e
-
→
t
t
¯
H
and
e
+
e
-
→
H
H
ν
e
ν
¯
e
allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.
This paper, based on the invited talk at the 20th Lomonosov Conference of Elementary Particle Physics, provides short overview of the Higgs physics program at future linear colliders as Higgs ...factories.
Cross sections for elastic and proton-dissociative photoproduction of
J
/
ψ
mesons are measured with the H1 detector in positron-proton collisions at HERA. The data were collected at
ep
...centre-of-mass energies
and
, corresponding to integrated luminosities of
and
, respectively. The cross sections are measured as a function of the photon-proton centre-of-mass energy in the range 25<
W
γp
<110 GeV. Differential cross sections d
σ
/d
t
, where
t
is the squared four-momentum transfer at the proton vertex, are measured in the range |
t
|<1.2 GeV
2
for the elastic process and |
t
|<8 GeV
2
for proton dissociation. The results are compared to other measurements. The
W
γp
and
t
-dependences are parametrised using phenomenological fits.
Based on a paper published in 2019 by the FCAL Collaboration, this talk is giving an update of the Collaboration's effort to design prototype of highly compact calorimeter to instrument the very ...forward region of a detector at future \(e^+e^-\) colliders. A luminometer prototype, based on sub-millimeter thick detector planes, is tested with an electron-beam of energy 1-5 GeV. The effective Moliere radius of the prototype comprising eight detector planes was measured to be (8.1 +/- 0.1 (stat.) +/- 0.3 (syst.))mm, and the result is well reproduced by the Monte Carlo simulation.
A measurement is presented of the inclusive neutral current
e
±
p
scattering cross section using data collected by the H1 experiment at HERA during the years 2003 to 2007 with proton beam energies
E
...p
of 920, 575, and 460 GeV. The kinematic range of the measurement covers low absolute four-momentum transfers squared, 1.5 GeV
2
<
Q
2
<120 GeV
2
, small values of Bjorken
x
, 2.9⋅10
−5
<
x
<0.01, and extends to high inelasticity up to
y
=0.85. The structure function
F
L
is measured by combining the new results with previously published H1 data at
E
p
=920 GeV and
E
p
=820 GeV. The new measurements are used to test several phenomenological and QCD models applicable in this low
Q
2
and low
x
kinematic domain.
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future ...linear e
+
e
-
collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1–5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Molière radius at 5 GeV was determined to be (8.1 ± 0.1 (stat) ± 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 ± 0.1) mm. The dependence of the effective Molière radius on the electron energy in the range 1–5 GeV was also studied. Good agreement was obtained between data and MC simulation.