Methods from nonlinear dynamics (NLD) have shown new insights into heart rate (HR) variability changes under various physiological and pathological conditions, providing additional prognostic ...information and complementing traditional time- and frequency-domain analyses. In this review, some of the most prominent indices of nonlinear and fractal dynamics are summarized and their algorithmic implementations and applications in clinical trials are discussed. Several of those indices have been proven to be of diagnostic relevance or have contributed to risk stratification. In particular, techniques based on mono- and multifractal analyses and symbolic dynamics have been successfully applied to clinical studies. Further advances in HR variability analysis are expected through multidimensional and multivariate assessments. Today, the question is no longer about whether or not methods from NLD should be applied; however, it is relevant to ask which of the methods should be selected and under which basic and standardized conditions should they be applied.
Purpose
This study was conducted to test, in mountain running route conditions, the accuracy of the Polar V800™ monitor as a suitable device for monitoring the heart rate variability (HRV) of ...runners.
Method
Eighteen healthy subjects ran a route that included a range of running slopes such as those encountered in trail and ultra-trail races. The comparative study of a V800 and a Holter SEER 12 ECG Recorder™ included the analysis of RR time series and short-term HRV analysis. A correction algorithm was designed to obtain the corrected Polar RR intervals. Six 5-min segments related to different running slopes were considered for each subject.
Results
The correlation between corrected V800 RR intervals and Holter RR intervals was very high (
r
= 0.99,
p
< 0.001), and the bias was less than 1 ms. The limits of agreement (LoA) obtained for SDNN and RMSSD were (− 0.25 to 0.32 ms) and (− 0.90 to 1.08 ms), respectively. The effect size (ES) obtained in the time domain HRV parameters was considered small (ES < 0.2). Frequency domain HRV parameters did not differ (
p
> 0.05) and were well correlated (
r
≥ 0.96,
p
< 0.001).
Conclusion
Narrow limits of agreement, high correlations and small effect size suggest that the Polar V800 is a valid tool for the analysis of heart rate variability in athletes while running high endurance events such as marathon, trail, and ultra-trail races.
Multiscale entropy (MSE) was proposed to characterize complexity as a function of the time-scale factor tau. Despite its broad use, this technique suffers from two limitations: (1) the artificial MSE ...reduction due to the coarse graining procedure and (2) the introduction of spurious MSE oscillations due to the suboptimal procedure for the elimination of the fast temporal scales. We propose a refined MSE (RMSE), and we apply it to simulations and to 24-h Holter recordings of heart rate variability (HRV) obtained from healthy and aortic stenosis (AS) groups. The study showed that the refinement relevant to the elimination of the fast temporal scales was more helpful at short scales (spanning the range of short-term HRV oscillations), while that relevant to the procedure of coarse graining was more useful at large scales. In healthy subjects, during daytime, RMSE was smaller at short scales (i.e., tau =1-2) and larger at longer scales (i.e., tau =4-20) than during nighttime. In AS population, RMSE was smaller during daytime both at short and long time scales (i.e., tau = 1 -11) than during nighttime. RMSE was larger in healthy group than in AS population during both daytime (i.e., tau = 2 -9) and nighttime (i.e., tau = 2). RMSE overcomes two limitations of MSE and confirms the complementary information that can be derived by observing complexity as a function of the temporal scale.
The level of sedation in patients undergoing medical procedures evolves continuously, affected by the interaction between the effect of the anesthetic and analgesic agents and the pain stimuli. The ...monitors of depth of anesthesia, based on the analysis of the electroencephalogram (EEG), have been progressively introduced into the daily practice to provide additional information about the state of the patient. However, the quantification of analgesia still remains an open problem. The purpose of this work is to improve the prediction of nociceptive responses with linear and non-linear measures calculated from EEG signal filtered in frequency bands higher than the traditional bands. Power spectral density and auto-mutual information function was applied in order to predict the presence or absence of the nociceptive responses to different stimuli during sedation in endoscopy procedure. The proposed measures exhibit better performances than the bispectral index (BIS). Values of prediction probability of Pk above 0.75 and percentages of sensitivity and specificity above 70% were achieved combining EEG measures from the traditional frequency bands and higher frequency bands.
Abstract Introduction Low-level electrocardiographic changes from depolarization wavefront may accompany acute myocardial ischemia. The purpose of this study was to assess the changes of microvolt ...amplitude intra-QRS potentials induced by elective percutaneous coronary interventions (PCI). Methods Fifty-seven patients with balloon inflation periods ranging from 3.1 to 7.3 minutes (4.9 ± 0.7 min) were studied. Nine leads continuous high-resolution ECG before and during PCI were recorded and signal-averaged. Abnormal intra-QRS at microvolt level (μAIQP) were obtained using a signal modeling approach. μAIQP, R-wave amplitude and QRS duration were measured in the processed ECG during baseline and PCI episodes. Results The mean μAIQP amplitude significantly decreased for each of the standard 12 leads at the PCI event respect to baseline. Left anterior descending artery (LAD) occlusion resulted in a decrease μAIQP in both the precordial leads and the limb leads, while right coronary (RCA) and left circumflex (LCx) arteries occlusions mainly affected limb leads. R-wave amplitude increased during PCI in RCA and LCx groups in lead III but decreased in the precordial leads, while the amplitude decreased in the LAD group in lead III. The average duration of the QRS augmented in groups RCA and LCx but not in the LAD group. Conclusions Abnormal intra-QRS potentials at the level of μV provide an excellent tool to characterize the very-low amplitude fragmentation of the QRS complex and its changes due to ischemic injuries. μAIQP shows promise as a new ECG index to measure electrophysiologic changes associated with acute myocardial ischemia.
We hypothesized that the implementation of automatic real-time assessment of quality of forced spirometry (FS) may significantly enhance the potential for extensive deployment of a FS program in the ...community. Recent studies have demonstrated that the application of quality criteria defined by the ATS/ERS (American Thoracic Society/European Respiratory Society) in commercially available equipment with automatic quality assessment can be markedly improved. To this end, an algorithm for assessing quality of FS automatically was reported. The current research describes the mathematical developments of the algorithm. An innovative analysis of the shape of the spirometric curve, adding 23 new metrics to the traditional 4 recommended by ATS/ERS, was done. The algorithm was created through a two-step iterative process including: (1) an initial version using the standard FS curves recommended by the ATS; and, (2) a refined version using curves from patients. In each of these steps the results were assessed against one expert's opinion. Finally, an independent set of FS curves from 291 patients was used for validation purposes. The novel mathematical approach to characterize the FS curves led to appropriate FS classification with high specificity (95%) and sensitivity (96%). The results constitute the basis for a successful transfer of FS testing to non-specialized professionals in the community.
The present study aimed to analyse the autonomic nervous system activity using heart rate variability (HRV) to detect sleep disordered breathing (SDB) patients with and without excessive daytime ...sleepiness (EDS) before sleep onset.
Two groups of 20 patients with different levels of daytime sleepiness -sleepy group, SG; alert group, AG- were selected consecutively from a Maintenance of Wakefulness Test (MWT) and Multiple Sleep Latency Test (MSLT) research protocol. The first waking 3-min window of RR signal at the beginning of each nap test was considered for the analysis. HRV was measured with traditional linear measures and with time-frequency representations. Non-linear measures -correntropy, CORR; auto-mutual-information function, AMIF- were used to describe the regularity of the RR rhythm. Statistical analysis was performed with non-parametric tests.
Non-linear dynamic of the RR rhythm was more regular in the SG than in the AG during the first wakefulness period of MSLT, but not during MWT. AMIF (in high-frequency and in Total band) and CORR (in Total band) yielded sensitivity > 70%, specificity >75% and an area under ROC curve > 0.80 in classifying SG and AG patients.
The regularity of the RR rhythm measured at the beginning of the MSLT could be used to detect SDB patients with and without EDS before the appearance of sleep onset.
The study assesses complexity of the cardiac control directed to the sinus node and to ventricles in long QT syndrome type 1 (LQT1) patients with KCNQ1-A341V mutation. Complexity was assessed via ...refined multiscale entropy (RMSE) computed over the beat-to-beat variability series of heart period (HP) and QT interval. HP and QT interval were approximated respectively as the temporal distance between two consecutive R-wave peaks and between the R-wave apex and T-wave end. Both measures were automatically taken from 24-hour electrocardiographic Holter traces recorded during daily activities in non mutation carriers (NMCs, n = 14) and mutation carriers (MCs, n = 34) belonging to a South African LQT1 founder population. The MC group was divided into asymptomatic (ASYMP, n = 11) and symptomatic (SYMP, n = 23) patients according to the symptom severity. Analyses were carried out during daytime (DAY, from 2PM to 6PM) and nighttime (NIGHT, from 12PM to 4AM) off and on beta-adrenergic blockade (BBoff and BBon). We found that the complexity of the HP variability at short time scale was under vagal control, being significantly increased during NIGHT and BBon both in ASYMP and SYMP groups, while the complexity of both HP and QT variability at long time scales was under sympathetic control, being smaller during NIGHT and BBon in SYMP subjects. Complexity indexes at long time scales in ASYMP individuals were smaller than those in SYMP ones regardless of therapy (i.e. BBoff or BBon), thus suggesting that a reduced complexity of the sympathetic regulation is protective in ASYMP individuals. RMSE analysis of HP and QT interval variability derived from routine 24-hour electrocardiographic Holter recordings might provide additional insights into the physiology of the cardiac control and might be fruitfully exploited to improve risk stratification in LQT1 population.
The aim of the study was to analyze heart rate variability (HRV) response to high-intensity exercise during a 35-km mountain trail race and to ascertain whether fitness level could influence ...autonomic nervous system (ANS) modulation. Time-domain, frequency-domain, and multi-scale entropy (MSE) indexes were calculated for eleven mountain-trail runners who completed the race. Many changes were observed, mostly related to exercise load and fatigue. These changes were characterized by increased mean values and standard deviations of the normal-to-normal intervals associated with sympathetic activity, and by decreased differences between successive intervals related to parasympathetic activity. Normalized low frequency (LF) power suggested that ANS modulation varied greatly during the race and between individuals. Normalized high frequency (HF) power, associated with parasympathetic activity, varied considerably over the race, and tended to decrease at the final stages, whereas changes in the LF/HF ratio corresponded to intervals with varying exercise load. MSE indexes, related to system complexity, indicated the existence of many interactions between the heart and its neurological control mechanism. The time-domain, frequency-domain, and MSE indexes were also able to discriminate faster from slower runners, mainly in the more difficult and in the final stages of the race. These findings suggest the use of HRV analysis to study cardiac function mechanisms in endurance sports.
Abnormal heart rate turbulence (HRT) has been documented as a strong predictor of total mortality and sudden death in postinfarction patients, but data in patients with congestive heart failure (CHF) ...are limited.
The aim of this study was to evaluate the prognostic significance of HRT for predicting mortality in CHF patients in New York Heart Association (NYHA) class II-III.
In 651 CHF patients with sinus rhythm enrolled into the MUSIC (Muerte Subita en Insuficiencia Cardiaca) study, the standard HRT parameters turbulence onset (TO) and slope (TS), as well as HRT categories, were assessed for predicting total mortality and sudden death.
HRT was analyzable in 607 patients, mean age 63 years (434 male), 50% of ischemic etiology. During a median follow up of 44 months, 129 patients died, 52 from sudden death. Abnormal TS and HRT category 2 (HRT2) were independently associated with increased all-cause mortality (HR: 2.10, CI: 1.41 to 3.12, P <.001 and HR: 2.52, CI: 1.56 to 4.05, P <.001; respectively), sudden death (HR: 2.25, CI: 1.13 to 4.46, P = .021 for HRT2), and death due to heart failure progression (HR: 4.11, CI: 1.84 to 9.19, P <.001 for HRT2) after adjustment for clinical covariates in multivariate analysis. The prognostic value of TS for predicting total mortality was similar in various groups dichotomized by age, gender, NYHA class, left ventricular ejection fraction, and CHF etiology. TS was found to be predictive for total mortality only in patients with QRS > 120 ms.
HRT is a potent risk predictor for both heart failure and arrhythmic death in patients with class II and III CHF.