•A large custom cryogen-free cryostat has been designed and built in order to operate the CUORE detector.•The CUORE cryostat has a 1 m3 experimental volume and is able to host a tonne-scale ...bolometric detector.•The CUORE cryostat guarantees a low noise and low radioactivity environment, needed to search for 0nbb.•The CUORE detector has been cooled down to 8.3 mK and steadily operated at 15 mK, proving the success of the cryostat.
The CUORE experiment is the world’s largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of ∼10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.
Abstract
Directional sensitivity to nuclear recoils would provide a smoking gun for a possible discovery of dark matter in the form of WIMPs (Weakly Interacting Massive Particles). A hint of ...directional dependence of the response of a dual-phase argon Time Projection Chamber (TPC) was found in the SCENE experiment. Given the potential importance of such a capability in the framework of dark matter searches, a new dedicated experiment, ReD (Recoil Directionality), was designed by the Global Argon Dark Matter Collaboration, in order to scrutinise this hint. A small dual-phase argon TPC was irradiated with neutrons produced by the p(
7
Li,
7
Be)n reaction using the 15 MV TANDEM accelerator of the INFN - Laboratori Nazionali del Sud, Catania, Italy, so as to produce argon nuclear recoils in the range (20 - 100) keV of interest for dark matter searches. Energy and direction of nuclear recoils are inferred by the detection of the elastically-scattered neutron by a set of scintillation detectors. Events were selected by gating of the associated
7
Be, which is detected by a telescope of Si detectors.
The CUORE Data Acquisition System Copello, S.; Di Domizio, S.; Branca, A. ...
Journal of low temperature physics,
04/2020, Letnik:
199, Številka:
1-2
Journal Article
Recenzirano
Odprti dostop
Large mass bolometers, thanks to their good energy resolution and high radiopurity, can be used for rare event searches, such as neutrinoless double beta decay or dark matter direct detection. The ...bolometric technique has been adopted by the CUORE experiment which is composed by an array of 988 tellurium dioxide bolometers with a total active mass of 741 kg. The experiment started taking data in April 2017 at the Laboratori Nazionali del Gran Sasso (LNGS), Italy, with the scientific goal of searching for neutrinoless double beta decay of 130-Te. Given the increasing number of channels to be acquired, the readout chain became an important aspect of the construction of bolometer arrays. The CUORE data acquisition system here described, called Apollo, was initially developed for CUORE, but its high modularity and flexibility make it possible to use it also in other experiments, regardless of the specific characteristics of the setup such as the number of channels and the bolometer characteristics. Indeed, it has been used not only in CUORE but also in its predecessor CUORE-0, R&D projects and upgrades such as CUPID-0.
The Recoil Directionality (ReD) Experiment Sanfilippo, S; Agnes, P; Albergo, S ...
Journal of physics. Conference series,
11/2022, Letnik:
2374, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Directional sensitivity to nuclear recoils would provide a smoking gun for a possible discovery of dark matter in the form of WIMPs (Weakly Interacting Massive Particles). A hint of directional ...dependence of the response of a dual-phase argon Time Projection Chamber (TPC) was found in the SCENE experiment. Given the potential importance of such a capability in the framework of dark matter searches, a new dedicated experiment, ReD (Recoil Directionality), was designed by the Global Argon Dark Matter Collaboration, in order to scrutinize this hint. Prior to the irradiation with a neutron beam, the ReD TPC underwent a long campaign of characterization and optimization: some selected results are presented in this contribution.
The CUORE Cryostat D’Addabbo, A.; Alduino, C.; Bersani, A. ...
Journal of low temperature physics,
12/2018, Letnik:
193, Številka:
5-6
Journal Article
Recenzirano
Odprti dostop
The Cryogenic Underground Observatory for Rare Events (CUORE) is a bolometric experiment for neutrinoless double-beta decay in
130
Te
search, currently taking data at the underground facility of ...Laboratori Nazionali del Gran Sasso (LNGS). The CUORE cryostat successfully cooled down a mass of about 1 ton at
∼
7
mK
, delivering a uniform and constant base temperature. This result marks a fundamental milestone in low-temperature detector techniques, opening the path for future ton-scale bolometric experiments searching for rare events. In this paper, we present the CUORE cryogenic infrastructure, briefly describing its critical subsystems.
A thermal calorimetric apparatus was designed, built and calibrated for measuring the activity of the artificial 144 Ce -144 Pr antineutrino source. This measurement will be performed at the ...Laboratori Nazionali del Gran Sasso in Italy, just before the source insertion in the tunnel under the Borexino detector and a precision better than 1% is required for a disappearance technique measurement in the SOX (Short distance neutrino Oscillation with BoreXino) project. In this work the apparatus is described and the most important results from the calibration measurements are shown, where the final precision of few per thousand is demonstrated.