Abstract Reconstruction methods from biplanar X-rays provide 3D analysis of spinal deformities for patients in standing position with a low radiation dose. However, such methods require an important ...reconstruction time and there is a clinical need for fast and accurate techniques. This study proposes and evaluates a novel reconstruction method of the spine from biplanar X-rays. The approach uses parametric models based on longitudinal and transversal inferences. A first reconstruction level, dedicated to routine clinical use, allows to get a fast estimate (reconstruction time: 2 min 30 s) of the 3D reconstruction and accurate clinical measurements. The clinical measurements precision (evaluated on asymptomatic subjects, moderate and severe scolioses) was between 1.2° and 5.6°. For a more accurate 3D reconstruction (complex pathologies or research purposes), a second reconstruction level can be obtained within a reduced reconstruction time (10 min) with a fine adjustment of the 3D models. The mean shape accuracy in comparison with CT-scan was 1.0 mm. The 3D reconstruction method precision was 1.8 mm for the vertebrae position and between 2.3° and 3.9° for the orientation. With a reduced reconstruction time, an improved accuracy and precision and a method proposing two reconstruction levels, this approach is efficient for both clinical routine uses and research purposes.
Abstract Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture ...devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values ( offset <1°) and angular patterns ( SD <0.3° and CMC >0.9). In comparison to the reference system, this functional procedure showed high precision ( SD <2° and CC >0.75) and moderate accuracy (between 4.0° and 8.1°) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.
To date, 3D spine reconstruction from biplanar radiographs involves intensive user supervision and semi-automated methods that are time-consuming and not effective in clinical routine. This paper ...proposes a new, fast, and automated 3D spine reconstruction method through which a realistic statistical shape model of the spine is fitted to images using convolutional neural networks (CNN). The CNNs automatically detect the anatomical landmarks controlling the spine model deformation through a hierarchical and gradual iterative process. The performance assessment used a set of 68 biplanar radiographs, composed of both asymptomatic subjects and adolescent idiopathic scoliosis patients, in order to compare automated reconstructions with ground truths build using multiple experts-supervised reconstructions. The mean (SD) errors of landmark locations (3D Euclidean distances) were 1.6 (1.3) mm, 1.8 (1.3) mm, and 2.3 (1.4) mm for the vertebral body center, endplate centers, and pedicle centers, respectively. The clinical parameters extracted from the automated 3D reconstruction (reconstruction time is less than one minute) presented an absolute mean error between 2.8° and 4.7° for the main spinal parameters and between 1° and 2.1° for pelvic parameters. Automated and expert's agreement analysis reported that, on average, 89% of automated measurements were inside the expert's confidence intervals. The proposed automated 3D spine reconstruction method provides an important step that should help the dissemination and adoption of 3D measurements in clinical routine.
We have developed a method to study the statistical properties of the noise found in various medical images. The method is specifically designed for types of noise with uncorrelated fluctuations. ...Such signal fluctuations generally originate in the physical processes of imaging rather than in the tissue textures. Various types of noise (e.g., photon, electronics, and quantization) often contribute to degrade medical images; the overall noise is generally assumed to be additive with a zero-mean, constant-variance Gaussian distribution. However, statistical analysis suggests that the noise variance could be better modeled by a nonlinear function of the image intensity depending on external parameters related to the image acquisition protocol. We present a method to extract the relationship between an image intensity and the noise variance and to evaluate the corresponding parameters. The method was applied successfully to magnetic resonance images with different acquisition sequences and to several types of X-ray images.
The robustness and accuracy of the intensity-based 3D/2D registration of a 3D model on planar X-ray image(s) is related to the quality of the image correspondences between the digitally reconstructed ...radiographs (DRR) generated from the 3D models (varying image) and the X-ray images (fixed target). While much effort may be devoted to generating realistic DRR that are similar to real X-rays (using complex X-ray simulation, adding densities information in 3D models, etc.), significant differences still remain between DRR and real X-ray images. Differences such as the presence of adjacent or superimposed soft tissue and bony or foreign structures lead to image matching difficulties and decrease the 3D/2D registration performance. In the proposed method, the X-ray images were converted into DRR images using a GAN-based cross-modality image-to-images translation. With this added prior step of XRAY-to-DRR translation, standard similarity measures become efficient even when using simple and fast DRR projection. For both images to match, they must belong to the same image domain and essentially contain the same kind of information. The XRAY-to-DRR translation also addresses the well-known issue of registering an object in a scene composed of multiple objects by separating the superimposed or/and adjacent objects to avoid mismatching across similar structures. We applied the proposed method to the 3D/2D fine registration of vertebra deformable models to biplanar radiographs of the spine. We showed that the XRAY-to-DRR translation enhances the registration results, by increasing the capture range and decreasing dependence on the similarity measure choice since the multi-modal registration becomes mono-modal.
Abstract The aim of this study was to quantify the tibio-femoral contact point (CP) locations in healthy and osteoarthritic (OA) subjects during a weight-bearing squat using stand-alone biplanar ...X-ray images. Ten healthy and 9 severe OA subjects performed quasi-static squats. Bi-planar X-ray images were recorded at 0°, 15°, 30°, 45°, and 70° of knee flexion. A reconstruction/registration process was used to create 3D models of tibia, fibula, and femur from bi-planar X-rays and to measure their positions at each posture. A weighted centroid of proximity algorithm was used to calculate the tibio-femoral CP locations. The accuracy of the reconstruction/registration process in measuring the quasi-static kinematics and the contact parameters was evaluated in a validation study. The quasi-static kinematics data revealed that in OA knees, adduction angles were greater ( p <0.01), and the femur was located more medially relative to the tibia ( p <0.01). Similarly, the average CP locations on the medial and lateral tibial plateaus of the OA patients were shifted (6.5±0.7 mm; p <0.01) and (9.6±3.1 mm; p <0.01) medially compared to the healthy group. From 0° to 70° flexion, CPs moved 8.1±5.3 mm and 8.9±5.3 mm posteriorly on the medial and lateral plateaus of healthy knees; while in OA joints CPs moved 10.1±8.4 mm and 3.6±2.8 mm posteriorly. The average minimum tibio-femoral bone-to-bone distances of the OA joints were lower in both compartments ( p <0.01). The CPs in the OA joints were located more medially and displayed a higher ratio of medial to lateral posterior translations compared to healthy joints.
This paper presents an in vivo validation of a method for the three-dimensional (3-D) high-resolution modeling of the human spine, rib cage, and pelvis for the study of spinal deformities. The method ...uses an adaptation of a standard close-range photogrammetry method called direct linear transformation to reconstruct the 3-D coordinates of anatomical landmarks from three radiographic images of the subject's trunk. It then deforms in 3-D 1-mm-resolution anatomical primitives (reference bones) obtained by serial computed tomography-scan reconstruction of a dry specimen. The free-form deformation is calculated using dual kriging equations. In vivo validation of this method on 40 scoliotic vertebrae gives an overall accuracy of 3.3 /spl plusmn/ 3.8 mm, making it an adequate tool for clinical studies and mechanical analysis purposes.
In clinical routine, lower limb analysis relies on conventional X-ray (2D view) or computerised tomography (CT) Scan (lying position). However, these methods do not allow 3D analysis in standing ...position. The aim of this study is to propose a fast and accurate 3D-reconstruction-method based on parametric models and statistical inferences from biplanar X-rays with clinical measurements' (CM) assessment in standing position for a clinical routine use. For the reproducibility study, the 95% CI was under 2.7° for all lower limbs' angular measurements except for tibial torsion, femoral torsion and tibiofemoral rotation ( < 5°). The 95% CI were under 2.5 mm for lower limbs' lengths and 1.5 to 3° for the pelvis' CM. Comparisons between X-rays and CT-scan based 3D shapes in vitro showed mean differences of 1.0 mm (95% CI = 2.4 mm). Comparisons of 2D lower limbs' and 3D pelvis' CM between standing 'Shifted-Feet' and 'Non-Shifted-Feet' position showed means differences of 0.0 to 1.4°. Significant differences were found only for pelvic obliquity and rotation. The reconstruction time was about 5 min.
The primary objective of this study was to develop a computer-aided method for the quantification of three-dimensional (3-D) cartilage changes over time in knees with osteoarthritis (OA). We ...introduced a local coordinate system (LCS) for the femoral and tibial cartilage boundaries that provides a standardized representation of cartilage geometry, thickness, and volume. The LCS can be registered in different data sets from the same patient so that results can be directly compared. Cartilage boundaries are segmented from 3-D magnetic resonance (MR) slices with a semi-automated method and transformed into offset-maps , defined by the LCS. Volumes and thickness are computed from these offset-maps. Further anatomical labeling allows focal volumes to be evaluated in predefined subregions. The accuracy of the automated behavior of the method was assessed, without any human intervention, using realistic, synthetic 3-D MR images of a human knee. The error in thickness evaluation is lower than 0.12 mm for the tibia and femur. Cartilage volumes in anatomical subregions show a coefficient of variation ranging from 0.11% to 0.32%. This method improves noninvasive 3-D analysis of cartilage thickness and volume and is well suited for in vivo follow-up clinical studies of OA knees.
Objectives: The Montreal Cognitive Assessement (MoCA) is a brief and standardized cognitive screening tool that has been used with several clinical populations. The aim of this study was to screen ...the early cognitive status of patients following mild traumatic brain injury (mTBI) with the MoCA.
Methods: The MoCA was administered within the first 2 weeks post-injury to 42 patients with uncomplicated mTBI, 92 patients with complicated mTBI and 50 healthy controls.
Results: Patients with complicated mTBI had a significantly lower performance (more impairments) on the total score of the MoCA than both the group with uncomplicated mTBI and the control group. Also, the group with uncomplicated mTBI had a significantly lower performance than controls. Moreover, age, education and TBI severity had a significant effect on the MoCA total score where younger, more educated and patients with less severe (higher GCS score) mTBI performed significantly better. Conclusions: The MoCA may be clinically useful to acutely screen cognition following mTBI.