Acta Phys.Hung. A25 (2006) 347-353 For the first time single-spin asymmetries in semi-inclusive pion production
are measured by the HERMES experiment with a transversely polarised hydrogen
target. ...Two different sine-modulations are extracted which can be related to
the transversity \delta q(x) and Sivers f_{1T}^{\perp q}(x) quark distribution
functions. The extracted sine-moments still contain small sub-leading twist
contributions which can be extracted from HERMES data combining the results
from the transversely polarised hydrogen target with previously measured
results from a longitudinally polarised hydrogen target.
Single-spin asymmetries in semi-inclusive pion production are measured by the
HERMES experiment for the first time, with a transversely polarised hydrogen
target. Two different sine-dependencies are ...extracted which can be related to
the quark distributions transversity h_1(x) and the Sivers function
f_1T^perp(x).
For the first time single-spin asymmetries in semi-inclusive pion production are measured by the HERMES experiment with a transversely polarised hydrogen target. Two different sine-modulations are ...extracted which can be related to the transversity \delta q(x) and Sivers f_{1T}^{\perp q}(x) quark distribution functions. The extracted sine-moments still contain small sub-leading twist contributions which can be extracted from HERMES data combining the results from the transversely polarised hydrogen target with previously measured results from a longitudinally polarised hydrogen target.
Single-spin asymmetries in semi-inclusive pion production are measured by the HERMES experiment for the first time, with a transversely polarised hydrogen target. Two different sine-dependencies are ...extracted which can be related to the quark distributions transversity h_1(x) and the Sivers function f_1T^perp(x).
Abstract Background Since the publication of the EVEREST II, MITRA-FR and COAPT trials, the domain of transcatheter edge-to-edge repair (TEER) for mitral regurgitation has been rapidly progressing. ...However, real-world data on peri-procedural outcomes are still limited. Purpose To analyse outcomes of peri-procedural healthcare resource utilisation and in-hospital safety after TEER between 2016 and 2019 in the United States. Methods The US National Inpatient Sample was utilised to identify adult patients undergoing TEER. Primary outcomes (hospital resource utilisation) were hospital length of stay (LOS), hospital costs and adverse discharge disposition to a nursing or rehabilitation facility. Secondary outcomes (safety) were in-hospital mortality, post-procedural bleedings, vascular complications, ischemic strokes, cardiogenic shocks, cardiac arrests and pericardial tamponades. Multivariable regression models were used to analyse outcomes. Results 4,020 adult patients undergoing a TEER procedure were included. The included population was relatively frail: average age of 78.1 years (±9.7), average Charlson Comorbidity Index of 3 IQR 1-4, average number of cardiovascular risk factors of 3 2-4 per patient, average CHA2DS2-VASc score of 4 3-5 and average simplified HAS-BLED score of 2 2-3. Distribution of the procedure was balanced between both sexes: 2,159 (53.7%) males vs. 1,861 (46.3%) females. Procedures were predominantly performed in large hospitals with 3,052 cases (75.9%), as well as in regional "hubs" at both US coastal regions with 543 cases (13.5%) in the Middle Atlantic region, 832 cases (20.7%) in the South Atlantic region, 535 cases (13.3%) in the East North Central region and 690 cases (17.2%) in the Pacific region. TEER procedure showed relatively save outcomes: 34 in-hospital deaths (0.8%), 119 (3.0%) post-procedural bleedings, 1 vascular complication requiring surgery, 24 (0.6%) ischemic strokes, 64 (1.6%) cardiogenic shocks, 20 (0.5%) cardiac arrests and 13 (0.3%) pericardial tamponades. Between 2016 and 2019, hospital LOS decreased by 22% 95% Confidence Interval (CI) 0.73-0.83, hospital costs by 6% 95% CI 0.90-0.98 and post-procedural discharge rates to a nursing or rehabilitation facility by 40% 95% CI 0.41-0.88; each P<0.001 (Figure). Post-procedural bleedings and cardiac arrests were reduced by 55% 95% CI 0.27-0.76 and 87% 95% CI 0.02-0.61 during the study period, respectively. In-hospital mortality, ischemic stroke, cardiogenic shock and pericardial tamponade decreased numerically but were not statistically significant (due to low overall event rates). Of note, there was a linear increase in all adverse outcomes with increasing patient comorbidity level (P for trend <0.001), particularly in patients with atrial fibrillation or flutter. Conclusion TEER procedure has become a safer and more efficient procedure. Careful considerations should be taken when performing the procedure in patients with multiple comorbidities.