This work presents a new methodology to evaluate the influence of wind speed data corrections in the fit of the Weibull distribution. Corrections are made for data measured by Sonic Detection and ...Ranging (SODAR) and MERRA-2 base data. SODAR data are corrected through Turbulence Intensity (TI). The MERRA-2 data correction uses National Institute of Meteorology (INMET) weather station data to find a local scale factor. The results showed that the corrected data present a better fit in the Weibull distribution and evidence that corrections are necessary when wind speed averages are used to evaluate the wind resource. Wind speed data were also applied to simulate the energy production by a commercial turbine to demonstrate the contrast in the total energy generated. The new methodology shows that IT must be considered in the evaluation of wind resources.
Tests of the T, CP and CPT symmetries in the neutral kaon system are performed by the direct comparison of the probabilities of a kaon transition process to its symmetry-conjugate. The exchange of in ...and out states required for a genuine test involving an antiunitary transformation implied by time-reversal is implemented exploiting the entanglement of K0K‾0 pairs produced at a ϕ-factory.
A data sample collected by the KLOE experiment at DAΦNE corresponding to an integrated luminosity of about 1.7 fb−1 is analysed to study the Δt distributions of the ϕ→KSKL→π+π−π±e∓ν and ϕ→KSKL→π±e∓ν3π0 processes, with Δt the difference of the kaon decay times. A comparison of the measured Δt distributions in the asymptotic region Δt≫τS allows to test for the first time T and CPT symmetries in kaon transitions with a precision of few percent, and to observe CP violation with this novel method.
A
bstract
The ratio
R
= Γ(
K
S
→ πeν
)
/
Γ(
K
S
→ π
+
π
−
) has been measured with a sample of 300 million
K
S
mesons produced in
ϕ → K
L
K
S
decays recorded by the KLOE experiment at the DAΦNE
e
+
e
...−
collider.
K
S
→ πeν
events are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of
K
L
→ πeν
decays are used to evaluate signal selection efficiencies. With 49647
±
316 signal events we measure
R
= (1
.
0421
±
0
.
0066
stat
±
0
.
0075
syst
)
×
10
−
3
. The combination with our previous measurement gives
R
= (1
.
0338
±
0
.
0054
stat
±
0
.
0064
syst
)
×
10
−
3
. From this value we derive the branching fraction
B
(
K
S
→ πeν
) = (7
.
153
±
0
.
037
stat
±
0
.
044
syst
)
×
10
−
4
and
f
+
(0)
|V
us
|
= 0
.
2170
±
0
.
009.
Abstract
We report a preliminary result on the sensitivity and analysis techniques to search for double beta decay of
130
Te to the first 0
+
excited state of
130
Xe in CUORE. With a TeO
2
exposure ...of 369.9 kg ⋅ y, we find an expected limit setting sensitivity of
T
1
/
2
0
v
>
3
⋅
10
24
y at 90 % C.I.
The 1-ton-scale CUORE detector is made of 988
TeO
2
crystals operated as cryogenic bolometers at a working temperature of
∼
10
mK
. In order to provide the necessary cooling power at 4 K stage, a ...total of five pulse tube (PT) refrigerators are used. The PTs make the cryogenic system reliable and stable, but have the downside that mechanical vibrations at low frequencies (1.4 Hz and related harmonics) are injected into the experimental apparatus. An active noise cancellation technique has been developed in order to reduce such effect by taking advantage from the coherent interference of the pressure oscillations originated by the different PTs. The technique that will be presented consists in controlling the relative phases of the pressure waves running inside the CUORE PT lines, in order to achieve the lowest detector noise. By reducing the power of PT harmonics by a factor up to
10
4
, it drastically suppresses the overall noise RMS on the CUORE detector. In the following, we demonstrate the reliability and effectiveness of the technique, showing that the optimization of the detector noise level is possible in different experimental conditions.
Oral contraceptives (OCs) have been the preferred method of birth control because of their high rate of effectiveness. OC use, however, has been associated with women's sexual health complaints and ...androgen insufficiency. OC use is associated with a decrease of androgen ovarian synthesis and an increase in the production of sex hormone-binding globulin (SHBG). There have been limited studies assessing SHBG values after discontinuation of OC use.
To retrospectively investigate SHBG levels before and after discontinuation of OC use.
Sex hormone-binding globulin values were compared at baseline, while on the OC, and well beyond the 7-day half-life of SHBG at 49-120 (mean 80) days and >120 (mean 196) days after discontinuation of OCs.
A total of 124 premenopausal women with sexual health complaints for >6 months met inclusion/exclusion criteria. Three groups of women were defined: (i) "Continued-Users" (N = 62; mean age 32 years) had been on OCs for >6 months and continued taking them; (ii) "Discontinued-Users" (N = 39; mean age 33 years) had been on OCs for >6 months and discontinued them; and (iii) "Never-Users" (N = 23; mean age 36 years) had never taken OCs.
Sex hormone-binding globulin values in the "Continued-Users" were four times higher than those in the "Never-User" group (mean 157 +/- 13 nmol/L vs. 41 +/- 4 nmol/L; P < 0.0001). Despite a decrease in SHBG values after discontinuation of OC use, SHBG levels in "Discontinued-Users" remained elevated in comparison with "Never-Users" (N = 26; P < 0.0001 for >120 days).
In women with sexual dysfunction, SHBG changes in "Discontinued-Users" did not decrease to values consistent with "Never-Users." Long-term sexual, metabolic, and mental health consequences might result as a consequence of chronic SHBG elevation. Does prolonged exposure to the synthetic estrogens of OCs induce gene imprinting and increased gene expression of SHBG in the liver in some women? Prospective research is needed.
The primary aim of this study is to analyse the conformance of usual care patterns for persons with schizophrenia to treatment guidelines in three Italian Departments of Mental Health (DMHs). The ...secondary aim is to examine possible organisational and structural reasons accounting for variations among DMHs.
Within the framework of the Evaluation of Treatment Appropriateness in Schizophrenia (ETAS) project, 20 consensus quality of care indicators were developed. Ten concerned pharmacological treatment and ten encompassed general care and psychosocial rehabilitation interventions. Indicators were calculated using data from a stratified random sample of 458 patients treated at three DMHs located in North-Eastern, North-Western and Southern Italy. Patients' data were collected by combining information from medical charts and from a survey carried out by the health care professionals in charge of the patients. Data on the structural and organisational characteristics of the DMHs were retrieved from administrative databases. For each indicator, the number and percentage of appropriate interventions with and without moderators were calculated. Appropriateness was defined as the percentage of eligible patients receiving an intervention conformant with guidelines. Moderators, i.e., reasons justifying a discrepancy between the interventions actually provided and that recommended by guidelines were recorded. Indicators based on a sufficient number of eligible patients were further explored in a statistical analysis to compare the performance of the DMHs.
In the overall sample, the percentage of inappropriate interventions ranged from 11.1 to 59.3% for non-pharmacological interventions and from 5.9 to 66.8% for pharmacological interventions. Comparisons among DMHs revealed significant variability in appropriateness for the indicators 'prevention and monitoring of metabolic effects', 'psychiatric visits', 'psychosocial rehabilitation', 'family involvement' and 'work'. After adjusting the patient's gender, age and functioning, only the indicators 'Prevention and monitoring of metabolic effects', 'psychiatric visits' and 'work' continued to differ significantly among DMHs. The percentage of patients receiving appropriate integrated care (at least one appropriate non-pharmacological intervention and one pharmacological intervention) was significantly different among the three DMHs and lower than expected.
Our results underscore discrepancies among Italian DMHs in indicators that explore key aspects of care of patients with schizophrenia. The use of quality indicators and improved guideline adherence can address suboptimal clinical outcomes, and has the potential to reduce practice variations and narrow the gap between optimal and routine care.
The three precision measurements of the cross section σ(e+e− → π+π−γ(γ)) using initial state radiation by the KLOE collaboration provide an important input for the prediction of the hadronic ...contribution to the anomalous magnetic moment of the muon. These measurements are correlated for both statistical and systematic uncertainties and, therefore, the simultaneous use of these measurements requires covariance matrices that fully describe the correlations. We present the construction of these covariance matrices and use them to determine a combined KLOE measurement for σ(e+e− → π+π−γ(γ)). We find, from this combination, a two-pion contribution to the muon magnetic anomaly in the energy range 0.10 < s < 0.95 GeV2 of aμπ+π−=489.8±1.7stat±4.8sys×10−10.Data vectors and covariance matrices are available at http://www.lnf.infn.it/kloe/ppg/ppg_2017/ppg_2017.html.
A
bstract
The quantum interference between the decays of entangled neutral kaons is studied in the process
ϕ
→ K
S
K
L
→
π
+
π
−
π
+
π
−
, which exhibits the characteristic Einstein-Podolsky-Rosen ...correlations that prevent both kaons to decay into
π
+
π
−
at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon pair state, and to search for tiny decoherence and
CPT
violation effects, which may be justified in a quantum gravity framework.
The analysed data sample was collected with the KLOE detector at DAΦNE, the Frascati
ϕ
-factory, and corresponds to an integrated luminosity of about 1.7 fb
−
1
, i.e. to about 1
.
7 × 10
9
ϕ
→ K
S
K
L
decays produced. From the fit of the observed ∆
t
distribution, being ∆
t
the difference of the kaon decay times, the decoherence and
CPT
violation parameters of various phenomenological models are measured with a largely improved accuracy with respect to previous analyses.
The results are consistent with no deviation from quantum mechanics and
CPT
symmetry, while for some parameters the precision reaches the interesting level at which — in the most optimistic scenarios — quantum gravity effects might show up. They provide the most stringent limits up to date on the considered models.