Percutaneous mitral repair is rapidly developing as an alternative to cardiac surgery in select patients. The Evalve percutaneous E2E system uses the MitraClip to replicate the surgical suture-based ...approach. This procedure requires real-time echocardiographic guidance in a unique and significant collaboration between echocardiographer and interventionalist. transesophageal echocardiography (TEE) is used as the primary imaging modality to guide this procedure and is essential to its success.
In EVEREST I, the US multicenter phase I safety and feasibility trial, 47 patients with 3 or 4+ mitral regurgitation (MR) were enrolled. The trial involved a standardized echocardiographic imaging protocol with a standardized anatomic-based vocabulary, predetermined standard TEE views, preprocedural strategy meetings, and display of echocardiographic aids to optimize communication and procedural efficiency during placement of the clip.
TEE guidance facilitated the creation of a double-orifice mitral valve in all 47 patients enrolled (100%), and 40 patients were discharged with 1 or more clips (85%). At discharge, successful placement of a clip and <or= 2+ MR was present in 34 patients (74%). The standardized approach contributed to a reduction in the time to perform the procedure over the course of the trial at both initial and new sites.
TEE is essential to the guidance of percutaneous MitraClip E2E repair. A streamlined approach to echocardiographic guidance, using predetermined standardized views, a common anatomic-based vocabulary, preprocedural strategy meetings, and a display of echocardiographic aids in the catheterization laboratory shortens the procedure time and allows for efficient percutaneous repair.
Summary Background The post-2015 End TB Strategy proposes targets of 50% reduction in tuberculosis incidence and 75% reduction in mortality from tuberculosis by 2025. We aimed to assess whether these ...targets are feasible in three high-burden countries with contrasting epidemiology and previous programmatic achievements. Methods 11 independently developed mathematical models of tuberculosis transmission projected the epidemiological impact of currently available tuberculosis interventions for prevention, diagnosis, and treatment in China, India, and South Africa. Models were calibrated with data on tuberculosis incidence and mortality in 2012. Representatives from national tuberculosis programmes and the advocacy community provided distinct country-specific intervention scenarios, which included screening for symptoms, active case finding, and preventive therapy. Findings Aggressive scale-up of any single intervention scenario could not achieve the post-2015 End TB Strategy targets in any country. However, the models projected that, in the South Africa national tuberculosis programme scenario, a combination of continuous isoniazid preventive therapy for individuals on antiretroviral therapy, expanded facility-based screening for symptoms of tuberculosis at health centres, and improved tuberculosis care could achieve a 55% reduction in incidence (range 31–62%) and a 72% reduction in mortality (range 64–82%) compared with 2015 levels. For India, and particularly for China, full scale-up of all interventions in tuberculosis-programme performance fell short of the 2025 targets, despite preventing a cumulative 3·4 million cases. The advocacy scenarios illustrated the high impact of detecting and treating latent tuberculosis. Interpretation Major reductions in tuberculosis burden seem possible with current interventions. However, additional interventions, adapted to country-specific tuberculosis epidemiology and health systems, are needed to reach the post-2015 End TB Strategy targets at country level. Funding Bill and Melinda Gates Foundation
Abstract Objectives This study sought to evaluate the outcomes of the early experience of transcatheter mitral valve replacement (TMVR) with balloon-expandable valves in patients with severe mitral ...annular calcification (MAC) and reports the first large series from a multicenter global registry. Background The risk of surgical mitral valve replacement in patients with severe MAC is high. There are isolated reports of successful TMVR with balloon-expandable valves in this patient population. Methods We performed a multicenter retrospective review of clinical outcomes of patients with severe MAC undergoing TMVR. Results From September 2012 to July of 2015, 64 patients in 32 centers underwent TMVR with compassionate use of balloon-expandable valves. Mean age was 73 ± 13 years, 66% were female, and mean Society of Thoracic Surgeons score was 14.4 ± 9.5%. The mean mitral gradient was 11.45 ± 4.4 mm Hg and the mean mitral area was 1.18 ± 0.5 cm2 . SAPIEN valves (Edwards Lifesciences, Irvine, California) were used in 7.8%, SAPIEN XT in 59.4%, SAPIEN 3 in 28.1%, and Inovare (Braile Biomedica, Brazil) in 4.7%. Access was transatrial in 15.6%, transapical in 43.8%, and transseptal in 40.6%. Technical success according to Mitral Valve Academic Research Consortium criteria was achieved in 46 (72%) patients, primarily limited by the need for a second valve in 11 (17.2%). Six (9.3%) had left ventricular tract obstruction with hemodynamic compromise. Mean mitral gradient post-procedure was 4 ± 2.2 mm Hg, paravalvular regurgitation was mild or absent in all. Thirty-day all-cause mortality was 29.7% (cardiovascular = 12.5% and noncardiac = 17.2%); 84% of the survivors with follow-up data available were in New York Heart Association functional class I or II at 30 days (n = 25). Conclusions TMVR with balloon-expandable valves in patients with severe MAC is feasible but may be associated with significant adverse events. This strategy might be an alternative for selected high-risk patients with limited treatment options.
Abstract Background Symptomatic mitral regurgitation (MR) is associated with high morbidity and mortality that can be ameliorated by surgical valve repair or replacement. Despite this, many patients ...with MR do not undergo surgery. Transcatheter mitral valve replacement (TMVR) may be an option for selected patients with severe MR. Objectives This study aimed to examine the effectiveness and safety of TMVR in a cohort of patients with native valve MR who were at high risk for cardiac surgery. Methods Patients underwent transcatheter, transapical delivery of a self-expanding mitral valve prosthesis and were examined in a prospective registry for short-term and 30-day outcomes. Results Thirty patients (age 75.6 ± 9.2 years; 25 men) with grade 3 or 4 MR underwent TMVR. The MR etiology was secondary (n = 23), primary (n = 3), or mixed pathology (n = 4). The Society of Thoracic Surgeons Predicted Risk of Mortality was 7.3 ± 5.7%. Successful device implantation was achieved in 28 patients (93.3%). There were no acute deaths, strokes, or myocardial infarctions. One patient died 13 days after TMVR from hospital-acquired pneumonia. Prosthetic leaflet thrombosis was detected in 1 patient at follow-up and resolved after increased oral anticoagulation with warfarin. At 30 days, transthoracic echocardiography showed mild (1+) central MR in 1 patient, and no residual MR in the remaining 26 patients with valves in situ. The left ventricular end-diastolic volume index decreased (90.1 ± 28.2 ml/m2 at baseline vs. 72.1 ± 19.3 ml/m2 at follow-up; p = 0.0012), as did the left ventricular end-systolic volume index (48.4 ± 19.7 ml/m2 vs. 43.1 ± 16.2 ml/m2 ; p = 0.18). Seventy-five percent of the patients reported mild or no symptoms at follow-up (New York Heart Association functional class I or II). Successful device implantation free of cardiovascular mortality, stroke, and device malfunction at 30 days was 86.6%. Conclusions TMVR is an effective and safe therapy for selected patients with symptomatic native MR. Further evaluation of TMVR using prostheses specifically designed for the mitral valve is warranted. This intervention may help address an unmet need in patients at high risk for surgery. (Early Feasibility Study of the Tendyne Mitral Valve System Global Feasibility Study; NCT02321514 )
Abstract Background In EVEREST II (Endovascular Valve Edge-to-Edge Repair Study), treatment of mitral regurgitation (MR) with a novel percutaneous device showed superior safety compared with surgery, ...but less effective reduction in MR at 1 year. Objectives This study sought to evaluate the final 5-year clinical outcomes and durability of percutaneous mitral valve (MV) repair with the MitraClip device compared with conventional MV surgery. Methods Patients with grade 3+ or 4+ MR were randomly assigned to percutaneous repair with the device or conventional MV surgery in a 2:1 ratio (178:80). Patients prospectively consented to 5 years of follow-up. Results At 5 years, the rate of the composite endpoint of freedom from death, surgery, or 3+ or 4+ MR in the as-treated population was 44.2% versus 64.3% in the percutaneous repair and surgical groups, respectively (p = 0.01). The difference was driven by increased rates of 3+ to 4+ MR (12.3% vs. 1.8%; p = 0.02) and surgery (27.9% vs. 8.9%; p = 0.003) with percutaneous repair. After percutaneous repair, 78% of surgeries occurred within the first 6 months. Beyond 6 months, rates of surgery and moderate-to-severe MR were comparable between groups. Five-year mortality rates were 20.8% and 26.8% (p = 0.4) for percutaneous repair and surgery, respectively. In multivariable analysis, treatment strategy was not associated with survival. Conclusions Patients treated with percutaneous repair more commonly required surgery for residual MR during the first year after treatment, but between 1- and 5-year follow-up, comparably low rates of surgery for MV dysfunction with either percutaneous or surgical therapy endorse the durability of MR reduction with both repair techniques. (EVEREST II Pivotal Study High Risk Registry; NCT00209274 )
Sixty marrow transplant recipients with liver dysfunction underwent transvenous liver biopsy and measurement of the hepatic venous pressure gradient. Biopsies were done on 29 patients using a Cook ...needle inserted through the jugular vein, on 30 patients through the femoral vein with a Mansfield biopsy forceps, and on 1 patient using both instruments. The average number of evaluable portal spaces was 4.0 for aggregated Cook needle specimens and 5.2 for Mansfield forceps specimens. The average number of central venules was 2.6 for Cook needle specimens and 3.5 for Mansfield specimens. Tissue obtained with the Mansfield forceps had crush artifact, especially along the edges, making assessment of bile ducts more difficult than in Cook needle specimens. Liver histology aided management in 53/60 patients by confirming the clinical diagnosis in 24 (40%) and by providing additional diagnoses in 29 (48%). Hepatic venous pressure gradient > 10 mmHg correlated with a histologic diagnosis of veno-occlusive disease (P = 0.001); this gradient value provided 91% specificity and 86% positive predictive value. Eleven patients had bleeding complications, 9 after Cook needle biopsy and 2 after Mansfield forceps biopsy. There were 3 procedure-related deaths, 2 from intraperitoneal bleeding after Cook needle biopsy and 1 from femoral vein bleeding after Mansfield biopsy. We conclude that transvenous liver biopsy and pressure measurements provide useful diagnostic information in marrow transplant patients with liver disease. In our hands, the Mansfield forceps was associated with a lower risk of intra-abdominal bleeding and capsular perforation of the liver while providing adequate histology for diagnosis. Hepatic venous pressure gradients > 10 mmHg were highly specific for a diagnosis of veno-occlusive disease in this patient population.