Abstract Reconstruction methods from biplanar X-rays provide 3D analysis of spinal deformities for patients in standing position with a low radiation dose. However, such methods require an important ...reconstruction time and there is a clinical need for fast and accurate techniques. This study proposes and evaluates a novel reconstruction method of the spine from biplanar X-rays. The approach uses parametric models based on longitudinal and transversal inferences. A first reconstruction level, dedicated to routine clinical use, allows to get a fast estimate (reconstruction time: 2 min 30 s) of the 3D reconstruction and accurate clinical measurements. The clinical measurements precision (evaluated on asymptomatic subjects, moderate and severe scolioses) was between 1.2° and 5.6°. For a more accurate 3D reconstruction (complex pathologies or research purposes), a second reconstruction level can be obtained within a reduced reconstruction time (10 min) with a fine adjustment of the 3D models. The mean shape accuracy in comparison with CT-scan was 1.0 mm. The 3D reconstruction method precision was 1.8 mm for the vertebrae position and between 2.3° and 3.9° for the orientation. With a reduced reconstruction time, an improved accuracy and precision and a method proposing two reconstruction levels, this approach is efficient for both clinical routine uses and research purposes.
The primary objective of this study was to develop a computer-aided method for the quantification of three-dimensional (3-D) cartilage changes over time in knees with osteoarthritis (OA). We ...introduced a local coordinate system (LCS) for the femoral and tibial cartilage boundaries that provides a standardized representation of cartilage geometry, thickness, and volume. The LCS can be registered in different data sets from the same patient so that results can be directly compared. Cartilage boundaries are segmented from 3-D magnetic resonance (MR) slices with a semi-automated method and transformed into offset-maps , defined by the LCS. Volumes and thickness are computed from these offset-maps. Further anatomical labeling allows focal volumes to be evaluated in predefined subregions. The accuracy of the automated behavior of the method was assessed, without any human intervention, using realistic, synthetic 3-D MR images of a human knee. The error in thickness evaluation is lower than 0.12 mm for the tibia and femur. Cartilage volumes in anatomical subregions show a coefficient of variation ranging from 0.11% to 0.32%. This method improves noninvasive 3-D analysis of cartilage thickness and volume and is well suited for in vivo follow-up clinical studies of OA knees.
Objective: The aim of this study was to evaluate the reliability of a software tool that assesses knee cartilage volumes using magnetic resonance (MR) images. The objectives were to assess ...measurement reliability by: (1) determining the differences between readings of the same image made by the same reader 2 weeks apart (test–retest reliability), (2) determining the differences between the readings of the same image made by different readers (between-reader agreement), and (3) determining the differences between the cartilage volume readings obtained from two MR images of the same knee image acquired a few hours apart (patient positioning reliability).
Methods: Forty-eight MR examinations of the knee from normal subjects, patients with different stages of symptomatic knee osteoarthritis (OA), and a subset of duplicate images were independently and blindly quantified by three readers using the imaging system. The following cartilage areas were analyzed to compute volumes: global cartilage, medial and lateral compartments, and medial and lateral femoral condyles.
Results: Between-reader agreement of measurements was excellent, as shown by intra-class correlation (ICC) coefficients ranging from 0.958 to 0.997 for global cartilage (P<0.0001), 0.974 to 0.998 for the compartments (P<0.0001), and 0.943 to 0.999 for the condyles(P<0.0001). Test–retest reliability of within-reader data was also excellent, with Pearson correlation coefficients ranging from 0.978 to 0.999 (P<0.0001). Patient positioning reliability was also excellent, with Pearson correlation coefficients ranging from 0.978 to 0.999 (P<0.0001).
Conclusions: The results of this study establish the reliability of this MR imaging system. Test–retest reliability, between-reader agreement, and patient positioning reliability were all extremely high. This study represents a first step in the overall validation of an imaging system designed to follow progression of human knee OA.